Manuale per l’uso Cabletron Systems FDDI Repeater

29 pagine 0.32 mb
Scarica

Vai alla pagina of 29

Summary
  • Cabletron Systems FDDI Repeater - page 1

    MMAC-Plus ™ 9F206-02 FDDI Repeater MicroLAN ™ Module User’s Guide ...

  • Cabletron Systems FDDI Repeater - page 2

    i Notice Notice Cabletron Systems r eserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletr on Systems to determine whether any such changes have been made. The hardwar e, firmware, or softwar e described in this manual is subject to ...

  • Cabletron Systems FDDI Repeater - page 3

    Notice ii FCC Notice This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference r eceived, including interference that may cause undesir ed operation. NOTE: This equipment has been tested and found to c ...

  • Cabletron Systems FDDI Repeater - page 4

    iii Notice Safety Inf ormation CLASS 1 LASER TRANSCEIVERS The FPIM-05 and FPIM-07 are Class 1 Laser Pr oducts The FPIM-05 and FPIM-07 use Class 1 Laser transceivers. Read the f ollowing safety inf ormation bef ore installing or operating these adapters. The Class 1 laser transceivers use an optical feedback loop to maintain Class 1 operation limits ...

  • Cabletron Systems FDDI Repeater - page 5

    Notice iv Safety Inf ormation CLASS 1 LASER TRANSCEIVERS Laser Radiation and Connectors When the connector is in place, all laser radiation remains within the fiber . The maximum amount of radiant power exiting the fiber (under normal conditions) is -12.6 dBm or 55 x 10 -6 watts. Removing the optical connector from the transceiver allows laser ra ...

  • Cabletron Systems FDDI Repeater - page 6

    v Contents Chapter 1 Intr oduction Features........................................................................................................................... 1-1 Related Manuals ............................................................................................................ 1-4 Getting Help ..................................... ...

  • Cabletron Systems FDDI Repeater - page 7

    1-1 Chapter 1 Intr oduction The 9F206-02 (as shown in Figure 1-1) is an FDDI r epeater module for the MMAC-Plus that provides external access to the Flexible Network Bus (FNB) backplane via two sets of FDDI-compliant A/B ports. This allows the FNB to traverse multiple MMAC-Plus systems, or connect to any ASNI FDDI-compliant device in an FDDI networ ...

  • Cabletron Systems FDDI Repeater - page 8

    Introduction 1-2 LANVIEW LEDs The 9F206-02 uses LANVIEW: the Cabletr on Systems built-in visual diagnostic and status monitoring system for at-a-glance diagnosis of the network. W ith LANVIEW LEDs, you can quickly identify the device, port, and physical layer status. Hot Swapping The 9F206-02 can be installed or removed fr om the chassis while the ...

  • Cabletron Systems FDDI Repeater - page 9

    1-3 F eatures Figure 1-1. The 9F206-02 Module SMB CPU MMAC PLUS ...

  • Cabletron Systems FDDI Repeater - page 10

    Introduction 1-4 Related Manuals The manuals listed below should be used to supplement the procedur es and technical data contained in this manual. MMAC-Plus Installation Guide MMAC-Plus Operations Guide MMAC-Plus 9C300-1 Environmental Module User ’ s Guide MMAC-Plus 9C214-AC Power Supply User ’ s Guide MMAC-Plus Module Local Management User ? ...

  • Cabletron Systems FDDI Repeater - page 11

    2-1 Chapter 2 Installing the Micr oLAN Module This module uses FPIMs for the front panel connections. They ar e not shipped with the module and must be purchased separately . For more information on FPIMs see Appendix A . Unpac king the Module 1. Carefully r emove the module from the shipping box. (Save the box and packing materials in the event th ...

  • Cabletron Systems FDDI Repeater - page 12

    Installing the MicroLAN Module 2-2 Figure 2-1. Installing an FPIM ...

  • Cabletron Systems FDDI Repeater - page 13

    2-3 User-Accessible Components User -Accessible Components Figure 2-2 shows the various components that ar e accessible to the user . These consist of an eight position dip switch (explained in the next section) and sockets for replaceable PROMs. These will be used for futur e upgrades. Instructions for installing the components will be supplied wi ...

  • Cabletron Systems FDDI Repeater - page 14

    Installing the MicroLAN Module 2-4 Setting the Module Car d DIP Switch An eight switch DIP switch is located on the module car d as shown in Figure 2-2 and Figure 2-3. The functions of the switches ar e listed in T able 2-1. Figure 2-3. Location of Module DIP Switch 1 2 3 4 5 6 7 8 ...

  • Cabletron Systems FDDI Repeater - page 15

    2-5 Setting the Module Card DIP Switch T able 2-1. Function of DIP Switch Switch Function Description On Off Factory Default 1 None Not Used. N/A N/A N/A 2 None Not Used. N/A N/A N/A 3 FNB-1 External Ring Specifies which ring is externalized for FNB-1. Primary Secondary Primary 4 FNB-2 External Ring Specifies which ring is externalized for FNB-2. P ...

  • Cabletron Systems FDDI Repeater - page 16

    Installing the MicroLAN Module 2-6 Installing the Module into the MMA C-Plus Chassis MMAC-Plus MicroLAN Modules can be installed in any of the 14 slots that ar e available. T o install, follow the steps below: 1. Switch off the power supplies and r emove all power from the MMAC-Plus chassis. 2. Remove the blank panels, covering the slots that the m ...

  • Cabletron Systems FDDI Repeater - page 17

    2-7 Installing the Module into the MMA C-Plus Chassis Figure 2-4. Installing the MicroLAN Module 7 FLNK 8 FLNK FLNK 10 FLNK INS 11 FLNK INS 12 RX TX RX TX RX Circuit Card Card Guides Metal Back-Panel Jack for ESD wrist strap W arning: Ensure that the circuit card is between the card guides . Lock do wn the top and bottom plastic tabs at the same ti ...

  • Cabletron Systems FDDI Repeater - page 18

    Installing the MicroLAN Module 2-8 The Reset Switch The Reset switch is located on the front panel, under the top plastic tab as shown in Figure 2-5. It serves two functions: • Pressing the Reset switch twice within thr ee seconds causes the main CPU to reset. • Pressing and holding the switch on for thr ee or more seconds causes the module to ...

  • Cabletron Systems FDDI Repeater - page 19

    3-1 Chapter 3 Operation The 9F206-02 module, as shown in Figure 3-1, pr ovides two repeater ports that extend the FNB bus outside the MMAC-Plus chassis. No bridging or routing is done in this module. Each port connects to both rings (Primary and Secondary) on each FNB (FNB-1 and FNB-2). Figure 3-1. 9F206-02 Block Diagram Fle xible Netw ork Bus (FNB ...

  • Cabletron Systems FDDI Repeater - page 20

    Operation 3-2 System Management Bus There ar e two management channels within the MMAC-Plus system: the SMB-1 and the SMB-10. These buses provide out-of-band management and inter -module management communication. The 9F206-02 uses only the SMB-1 bus. The SMB-1 is a 1 Mbps management bus located within the MMAC-Plus. This bus is utilized by all diag ...

  • Cabletron Systems FDDI Repeater - page 21

    3-3 CPU CPU The CPU handles all low level SMT functions as well as module configuration requests. The CPU is also r esponsible for all environmental, power and system level communication between modules in the MMAC-Plus chassis. ...

  • Cabletron Systems FDDI Repeater - page 22

    4-1 Chapter 4 LANVIEW LEDs The front panel LANVIEW LEDs indicate the status of the module and may be used as an aid in troubleshooting. Shown in Figur e 4-1 are the LANVIEW LEDs of the 9F206-02 module. Figure 4-1. 9F206-02 LANVIEW LEDs SMB CPU SMB and CPU FDDI Port Status ...

  • Cabletron Systems FDDI Repeater - page 23

    LANVIEW LEDs 4-2 The functions of the System Management Bus (SMB) and CPU LEDs are listed in T able 4-1. There is one r ow of FDDI Port Status LEDs for each FDDI ring, FNB-1 and FNB-2. The functions of the FDDI LEDs are shown in Figur e 4-2 and T able 4-2. Figure 4-2. FDDI LEDs T able 4-1. SMB and CPU LEDs LED Color State Description Green Function ...

  • Cabletron Systems FDDI Repeater - page 24

    4-3 LANVIEW LEDs The functions of the FDDI Port Status LEDs are listed in T able 4-2. The functions of the FDDI Status LEDs are listed in T able 4-3. T able 4-2. FDDI Port Status LEDs LED Color ST A TE Green Link, Active, Port Enabled Y ellow Link, Not Active, Port Enabled Red Not Link, Port Disabled Red (Flashing) Link, Port Disabled Off No Link, ...

  • Cabletron Systems FDDI Repeater - page 25

    5-1 Chapter 5 General Specifications Safety This equipment meets the following safety requir ements: • UL 1950 • CSA C22.2 No. 950 • EN 60950 • IEC 950 • EMI Requirements of FCC Part 15 Class A • EN 55022 Class A • VCCI Class I • EMC requir ements of the following: EN 50082-1 IEC 801-2 ESD IEC 801-3 Radiated susceptibility IEC 801- ...

  • Cabletron Systems FDDI Repeater - page 26

    General Specifications 5-2 Ph ysical Dimensions: 35.0 D x 44.0 H x 3.0 W centimeters (13.8 D x 17.4 H x 1.2 W inches) W eight: Unit: 1.36 kg. (3 lb) Shipping: 1.81 kg. (4 lb) ...

  • Cabletron Systems FDDI Repeater - page 27

    A-1 Appendix A FPIM Specifications This MMAC-Plus module uses Fiber Port Interface Modules (FPIM) to provide front panel cable connections. The FPIMs ar e user-installable. See the section titled Installing an FPIM on page 2-1. FPIM-00 and FPIM-01 The FPIM-00 and FPIM-01 provide a multimode fiber connection. The FPIM-00 uses a MIC style connector ...

  • Cabletron Systems FDDI Repeater - page 28

    FPIM Specifications A-2 T ransmitter power parameters are listed in T able A-2. The link distance is up to 2 kilometers on the multimode fiber-optic cable as specified by ANSI MMF-PMD. FPIM-02 and FPIM-04 The FPIM-02 has an RJ-45 connector supporting an Unshielded T wisted Pair (UTP) connection. The FPIM-04 has an RJ-45 connector supporting a Sh ...

  • Cabletron Systems FDDI Repeater - page 29

    A-3 FPIM-05 and FPIM-07 FPIM-05 and FPIM-07 The FPIM-05 and FPIM-07 provide a Single-mode fiber connection. The FPIM-05 uses a MIC style connector and the FPIM-07 uses an SC type connector . The specifications for both devices are listed in T able A-4. The link distance is up to 40 kilometers (max) and 25 kilometers (typical) on single mode fibe ...

Fabbricante Cabletron Systems Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoCabletron Systems FDDI Repeater possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Cabletron Systems
- manuali per l’uso FDDI Repeater
- schede prodotto Cabletron Systems
- opuscoli
- o etichette energetiche Cabletron Systems FDDI Repeater
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Cabletron Systems FDDI Repeater.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Cabletron Systems FDDI Repeater, manuali di manutenzione, brevi manuali o manuali utente Cabletron Systems FDDI Repeater. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Cabletron Systems FDDI Repeater.

Manuali per l’uso simili

Manuale completo del dispositivo Cabletron Systems FDDI Repeater, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Cabletron Systems FDDI Repeater dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Cabletron Systems FDDI Repeater.

Il manuale per l’uso completo Cabletron Systems, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Cabletron Systems FDDI Repeater - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Cabletron Systems FDDI Repeater, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Cabletron Systems FDDI Repeater che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Cabletron Systems FDDI Repeater - che ci dovrebbe aiutare nei primi passi durante l'uso Cabletron Systems FDDI Repeater
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Cabletron Systems FDDI Repeater
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Cabletron Systems FDDI Repeater in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Cabletron Systems FDDI Repeater?

Utilizza il modulo sottostante

Se non hai risolto il problema con Cabletron Systems FDDI Repeater con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Cabletron Systems FDDI Repeater è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)