Manuale per l’uso Fisher & Paykel DD605

28 pagine 7.2 mb
Scarica

Vai alla pagina of 28

Summary
  • Fisher & Paykel DD605 - page 1

    DishDra wer Installation instructions NZ A U GB IE DD605 and DS605 models ...

  • Fisher & Paykel DD605 - page 2

    Safety and warnings Impor tant safety precautions! Installation of this DishDrawer® requires basic mechanic al and electrical skills. Be sure to leave these Instructions with the Customer . Installation must comply with your loc al building and electricity regulations. At the completion of the DishDrawer® installation, the Installer m ust per for ...

  • Fisher & Paykel DD605 - page 3

    1 Contents DOUBLE MODELS Product and cabinetry dimensions 2 Installation Cavity prepar ation 4 Route the hoses and mov e into the cavity 5 Removing the tub and levelling the pr oduct 6 Securing the product and refitting the tub 7 Plumbing and drainage - OPTION 1 8 Plumbing and drainage - OPTION 1 (connection) 9 Plumbing and drainage - OPTION 2 10 P ...

  • Fisher & Paykel DD605 - page 4

    2 Pr oduc t dimensions O B C E D F G H J N P Pr oduct dimensions (mm) Pre nished L CD DD605 Pre nished Flat door DD605 Integrated DD605 A overall height* of product 819.5 - 879.5 819.5 - 879.5 819.5 - 879.5 B overall width of product 595 595 595 C overall depth of product (excl. curvature/handle) 570 570 570 D depth of drawer (open) (excl. cu ...

  • Fisher & Paykel DD605 - page 5

    3 Cabinetry dimensions A B C D Cabinetry dimensions (mm) Pre nished LC D DD605 Pre nished Flat door DD605 Integrated DD605 A inside height of cavity 820 - 882.5 820 - 882.5 820 - 882.5 B inside width of cavity 600 600 600 C inside depth of cavity (inside) 580 580 580 D height of adjacent cabinetry 720 720 720 E height of kickstrip 70 - 120 70 ...

  • Fisher & Paykel DD605 - page 6

    4 Note: Services can be located either side of DishDr awer®. Ca vity preparation Parts supplied These marks indicate mounting tab screw locations Pref erred position. If adequate clearance, services hole can be higher to clear toe kick space. If hole is higher , ensure drain hose(s) are r outed straight into the waste connection. Clamp (1) Wire cl ...

  • Fisher & Paykel DD605 - page 7

    5 Route the hoses and mov e into the ca vity DOUBLE MODELS 2 1 1 1 2 3 3 optional 1 b 2 optional 1 a Tie together to a void kink ing If top two tabs are being used, ensure they’r e securely fitted before sliding pr oduct into cavity . Ensure hoses and cord are not kinked or twisted. Loosen feet first, but do not fully extend until product is in c ...

  • Fisher & Paykel DD605 - page 8

    6 Removing the tub and lev elling the product 30 mm x 4 1 2 3 4 5 5 1 2 3 4 5 3 DOUBLE MODELS 4 Ensure the tub is remov ed and then rotated counter-clockwise to prevent kinked hoses. Ensure product is level. U sing the most appropriate length Hexagonal socket supplied, and a screw driver , fully extend levelling feet up to r equired distance. Hexag ...

  • Fisher & Paykel DD605 - page 9

    7 Securing the product and re tting the tub DOUBLE MODELS A 1 2 4 5 4 3 C C BB A 5 6 optional The mounting tabs are in pairs, one on each side of the product. At least two sets of tab pairs must be used. A and B tab pairs OR B and C tab pairs or all three pairs. Ensure the sound insulation is repositioned correctly . Before r efitting the tub, e ...

  • Fisher & Paykel DD605 - page 10

    8 DishDraw er® and Standpipe Ø 38 mm W ater Pr essure Max Min W ater softener models 1 MPa (145 psi) 0.1 MP a (14.5 psi) Other models 1 MP a (145 psi) 0.03 MPa (4.3 psi) Drains will need to be separated to satisfy Kosher requir ements. W e suggest you confirm acceptability with your local Rabbi in respect to Kosher installations. Plumbing and dra ...

  • Fisher & Paykel DD605 - page 11

    9 Plumbing and drainage - OPTION 1 (c onnec tion) DOUBLE MODELS 2 750- 882.5 mm 38 mm max. 120 mm 4 3 2 1 1 180 o 7 If space is limited for fixing, push hose through drain hose support to required height DishDraw er® and Standpipe Ø 38 mm 8 Fit supplied washer ...

  • Fisher & Paykel DD605 - page 12

    10 DishDraw er® using sink trap with drain hose joiner Plumbing and drainage - OPTION 2 DOUBLE MODELS 750 - 882.5 mm Wa st e Va lv e Wa te r supply (COLD) Supplied drain hose joiner min. R200 mm HIGHL OOP min. 150 mm ...

  • Fisher & Paykel DD605 - page 13

    11 Plumbing and drainage - OPTION 2 (c onnec tion) DOUBLE MODELS 2 3 750- 882.5 mm 1 4 3 2 1 180 o DishDraw er® using sink trap with drain hose joiner If space is limited for fixing, push hose through drain hose support to required height 7 8 Fit supplied washer Ensure hoses are rout ed straight to joiner . Remove excess hose material if necessary ...

  • Fisher & Paykel DD605 - page 14

    12 F itting the toekick 1 2 3 4 5 6 7 8 9 10 19 9 10 DOUBLE MODELS Impor tant! D o not overtighten screw . ...

  • Fisher & Paykel DD605 - page 15

    13 ...

  • Fisher & Paykel DD605 - page 16

    14 Pr oduc t dimensions A B C E D F G H J K L Pr oduct dimensions (mm) Pre nished L CD DS605 Pre nished Flat door DS605 Integrated DS605 A overall height* of product 409 409 409 B overall width of product 595 595 595 C overall depth of product (excl. curvature/handle) 570 570 570** D depth of drawer (open) (excl. curvature/handle) 520 520 520 ...

  • Fisher & Paykel DD605 - page 17

    15 Cabinetry dimensions A B C D Cabinetry dimensions (mm) Pre nished LC D DS605 Pre nished Flat door DS605 Integrated DS605 A inside height of cavity 412 412 412 B inside width of cavity 600 600 600 C inside depth of cavity (inside) 580 580 580 D clearance below benchtop Minimum 3* Minimum 3* Minimum 3* * Clearance is measured from the unders ...

  • Fisher & Paykel DD605 - page 18

    16 Ca vity preparation Cavit y These marks indicate mounting tab screw locations Note: T o align drawer front to adjacent cabinetry , the product to counter top clearance can be increased to 3 mm. Pref erred position. If adequate clearance, services hole can be higher . If hole is higher , ensure drain hose(s) are r outed straight into the waste co ...

  • Fisher & Paykel DD605 - page 19

    17 SINGLE MODELS Route the hoses and mov e into the cavity 1 1 1 2 2 2 Tie together to a void kink ing 1 b 2 1 a Ensure hoses and cord are not kinked or twisted. ...

  • Fisher & Paykel DD605 - page 20

    18 Removing the tub and securing the pr oduc t 2 30 mm 1 5 5 3 4 SINGLE MODELS 3 4 Ensure the tub is remov ed and then rotated counter-clockwise to prevent kinked hoses. The mounting tabs are in pairs, one on each side of the product. Ensure the sound insulation is repositioned correctly . ...

  • Fisher & Paykel DD605 - page 21

    19 Re tting the tub 2 1 4 5 4 3 SINGLE MODELS 5 Before r efitting the tub, ensure the hoses are not twisted and the latches at the rear of each drawer runner are facing forward. Ensure the tub clips on both sides are reset. Ensure the tub is now rotated clockwise back. ...

  • Fisher & Paykel DD605 - page 22

    20 DishDraw er® and Standpipe Ø 38 mm W ater Pr essure Max Min W ater softener models 1 MPa (145 psi) 0.1 MP a (14.5 psi) Other models 1 MP a (145 psi) 0.03 MPa (4.3 psi) Plumbing and drainage - OPTION 1 750 - 882.5 mm Wa st e Wa st e Va lv e Wa te r supply (C OLD) W aste disposal (optional) Do not connect to DishDrawer® min. R200 mm SINGLE MODE ...

  • Fisher & Paykel DD605 - page 23

    21 Plumbing and drainage - OPTION 1 (c onnec tion) 2 1 750- 882.5 mm 38 mm max. 120 mm 4 3 2 1 180 o DishDraw er® and Standpipe Ø 38 mm SINGLE MODELS If space is limited for fixing, push hose through drain hose support to required height 7 8 Fit supplied washer ...

  • Fisher & Paykel DD605 - page 24

    22 Plumbing and drainage - OPTION 2 DishDraw er® using sink trap with drain hose joiner 750 - 882.5 mm Va lv e Wa st e Wa te r supply (COLD) Supplied drain hose joiner min. R200 mm SINGLE MODELS HIGHL OOP min. 150 mm ...

  • Fisher & Paykel DD605 - page 25

    23 Plumbing and drainage - OPTION 2 (c onnec tion) 2 3 750- 882.5 mm 38 mm max. 120 mm 1 4 3 2 1 180 o DishDraw er® using sink trap with drain hose joiner SINGLE MODELS If space is limited for fixing, push hose through drain hose support to required height 7 8 Fit supplied washer ...

  • Fisher & Paykel DD605 - page 26

    24 F inal checklist Check all parts are installed. Ensure product is level, secur ely fastened to the cabinetry and opens and closes freely . The DishDrawer® must be free t o fully close with no resistance from the cabinetry . Ensure inlet hose to water supply has rubber washer fitted and is tight ened a fur ther half turn after seal contact. Ensu ...

  • Fisher & Paykel DD605 - page 27

    ...

  • Fisher & Paykel DD605 - page 28

    Copyright © F isher & Pa ykel 2007. All rights reserved. The product specifications in this booklet apply to the specific products and models described at the date of issue. Under our policy of continuous product improvement, these specifications may change at an y time. Y ou should therefor e check with your Dealer to ensure this booklet corr ...

Fabbricante Fisher & Paykel Categoria Dishwasher

I documenti che otteniamo dal fabbricante del dispositivoFisher & Paykel DD605 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Fisher & Paykel
- manuali per l’uso DD605
- schede prodotto Fisher & Paykel
- opuscoli
- o etichette energetiche Fisher & Paykel DD605
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Fisher & Paykel DD605.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Fisher & Paykel DD605, manuali di manutenzione, brevi manuali o manuali utente Fisher & Paykel DD605. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Fisher & Paykel DD605.

Manuale completo del dispositivo Fisher & Paykel DD605, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Fisher & Paykel DD605 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Fisher & Paykel DD605.

Il manuale per l’uso completo Fisher & Paykel, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Fisher & Paykel DD605 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Fisher & Paykel DD605, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Fisher & Paykel DD605 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Fisher & Paykel DD605 - che ci dovrebbe aiutare nei primi passi durante l'uso Fisher & Paykel DD605
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Fisher & Paykel DD605
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Fisher & Paykel DD605 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Fisher & Paykel DD605?

Utilizza il modulo sottostante

Se non hai risolto il problema con Fisher & Paykel DD605 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Fisher & Paykel DD605 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)