    GENERA C POWER SYSTEMS, INC. R R Installation and Owner’ s Man ual Air -cooled A utomatic Standb y Generators Models: 04758-1 (6 kW NG, 7 kW LP) 04759-1 (12 kW NG, 12 kW LP) 04760-1 (13 kW NG, 15 kW LP) DEADL Y EXHAUST FUMES. OUTDOOR INST ALLA TION ONL Y!! D ANGER Not intended f or use as Primary P o wer in place of utility or in life-support app ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 2

    I NTRODUCTION Thank you for purchasing this model by Generac P ower Systems Inc.. This model is a compact, high performance, air - cooled, engine - driven generator designed to automatically supply electrical power to operate critical loads during a utility power failure. This unit is factory installed in an all-weather , metal enclo- sure that is ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 3

    Generac® Pow er Systems, Inc. 1 T able of Cont ents Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Introduction ........................Inside F ront Cover Read This Manual Thoroughly ........................IFC Contents ..........................................................IFC Operation and Maintenance ............................IFC ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 4

    2 Generac ® Pow er Systems, Inc. Study these SAFETY RULES carefully before installing, operating or servicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , efficiently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing to fo ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 5

    ELE CTR ICAL HA Z AR DS • All generators covered by this manual produce dangerous electrical voltages and can cause fatal electrical shock. Utility power delivers extremely high and dangerous voltages to the transfer switch as does the standby generator when it is in opera- tion. A void contact with bare wires, terminals, con- nections, etc., whi ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 6

    Only qualified electricians or contractors should attempt such installations, which must comply strictly with applicable codes, standards and regulations. 1.1 U N P ACKING/I NSP ECTION After unpacking, carefully inspect the contents for damage. • This standby generator set has been factory sup- plied with a weather protective enclosure that is in ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 7

    Section 1 — General Information Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1.4 TH E GEN ER A T OR Control P anel Battery Compartment Fuel Inlet Air Filter Exhaust Enclosure Oil Filter Data Decal Fuel Regulator Oil Check/Fill Control Pan e l Air Filter Exhaust Enclosure Battery Compartment Fuel Inlet Oil Filter Oil Dipstick Data Decal ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 8

    Section 1 — General Information Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1.5 SP E CI F ICA TIONS 1.5.1 GEN ERA T OR Model 04758 Model 04759 Mo de l 04760 Rated Max. Continuous P ower Capacity (W atts*) 6,000 NG/7,000 LP 12,000 NG/12,000 LP 13,000 NG/15,000 LP† Rated V oltage 120/240 120/240 120/240 Rated Max. Continuous Load Curr ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 9

    1 . 6 FUE L RE QUIRE MEN T S AN D R E C OM M EN D A TIONS W ith LP gas, use only the vapor withdrawal system. This type of system uses the vapors formed above the liquid fuel in the storage tank. The engine has been fitted with a fuel carburetion system that meets the specifications of the 1997 California Air Resources Board for tamper -proof dual ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 10

    3. Remove the small hose clamp and hose from the fuel regulator . It may be necessary to pry the hose off of the brass fitting using a screw driver to gen- tly lift up the hose edge. 4. Remove the brass hose fitting screwed into the fuel regulator . 5. Locate and identify the brass idle jet. This will be located in the fuel regulator casting facing ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 11

    1.1 0 B A TTER Y INST ALLA TION Fill the battery with the proper electrolyte fluid if nec- essary and have the battery fully charged before installing it. Before installing and connecting the battery , complete the following steps: 1. Set the generator's A UTO/OFF/MANU AL switch to OFF . 2. T urn off utility power supply to the transfer switch ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 12

    The following procedur es are to be observed: • Wear full eye pr otection and protective clothing; • Where electr olyte contacts the skin, wash it of f immediately with water; • Where electr olyte contacts the eyes, immediately flush thoroughly with water and seek medical attention; and • Spilled electrolyte is to be washed down with an aci ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 13

    8. Connect an accurate AC voltmeter and a frequen- cy meter across transfer switch terminal lugs E1 and E2. V oltage should be 242-252 volts; fre- quency should read about 61-63 Hertz. 9. Connect the AC voltmeter test leads across termi- nal lug E1 and neutral; then across E2 and neu- tral. In both cases, voltage reading should be 121- 126 volts AC ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 14

    2.6 ADJ US TI NG TH E R E GU L A T OR (NA TUR AL GAS ONL Y) Although the generator has been factory set to pro- vide maximum power , it may be necessary in some areas to adjust this setting . Because natural gas has different BTU or power content across the country the engine may not perform as designed. If experiencing engine problems at high or f ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 15

    Section 3 — Operation Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Figure 2.3 — Engine Governor Adjustment 2.7 .2 1 2 KW AND 15 KW UN IT S 1. Loosen governor clamp bolt (See Figure 2.3). 2. Completely remove the idle spring . 3. W ith governor arm at wide open throttle position, rotate governor shaft fully clockwise. Tighten clamp bo ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 16

    Section 3 — Operation Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 8. T urn ON the utility power supply to the transfer switch, which will allow the transfer switch to transfer back to utility power . The unit will con- tinue to run for one minute and then shut down. 9. Allow the unit to cool. 10. Drain the oil and remove the oil filte ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 17

    D . Utility V oltage Pickup Sensor • This sensor monitors utility power supply volt- age. When that voltage is restored to above 70 percent of the nominal source voltage, a retrans- fer time delay starts timing . E. Retransfer Time Delay • This timer runs for about 15 seconds. • At end of a 15- second delay , circuit board action de - energiz ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 18

    3.6 SE T TI NG TH E EXERCISE TI M ER The generator is equipped with an exercise timer . Once it is set, the generator will start and exercise once every seven days, on the day of the week and at the time of day the following sequence is completed. During this exercise period, the unit runs for approx- imately 12 minutes and then shuts down. Transfe ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 19

    4.1 F USE The generator panel’s 15 amp fuse (Figure 4.1) protects the DC control circuit against overload. The fuse is wired in series with the battery output lead to the panel. If the fuse element has melted open, the engine cannot crank or start. Replace the fuse using only an identical 15-amp replacement. The generator panel’s 5 amp fuse pro ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 20

    4.3.2 OI L CHANGE PROCEDU R E T o change the oil, proceed as follows: 1. Run the engine until it is thoroughly warmed up then shut OFF the engine. 2. Immediately after the engine shuts OFF , pull the oil drain hose (Figure 4.4) free of its retaining clip. Remove the cap from the hose and drain the oil into a suitable container . Figure 4.4 – Oil ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 21

    4.6 SP AR K P L UG(S) Reset the spark plug(s) gap or replace the spark plug(s) as necessary . See Section 4.13 for mainte- nance requirements. 1. Clean the area around the base of the spark plug(s) to keep dirt and debris out of the engine. Clean by scraping or washing using a wire brush and commercial solvent. Do not blast the spark plug(s) to cle ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 22

    4.8 ADJ US TI NG V AL VE CLEAR ANCE After the first 50 hours of operation, adjust the valve clearance in the engine. Important: If feeling uncomfortable about doing this procedure or the proper tools are not available, please contact the Generac Authorized dealer for service assis- tance. This is a very important step to insure longest life for the ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 23

    4.1 0 A TTENTION AF TER S U B M ERSION If the generator has been submerged in water , it MUST NOT be started and operated. F ollowing any sub- mersion in water , have a Generac Authorized Dealer thor- oughly clean and dry the generator . 4.1 1 C OR ROSION P RO TECTION P eriodically wash and wax the enclosure using automo- tive type products. F requ ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 24

    Section 4 — Maintenance Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 4.1 3 SERVICE S CH EDU LE A TTENTION: It is recommended that all service work be performed by the nearest Generac Authorized Dealer . SYSTEM/COMPONENT PROCEDURE FREQUENCY X = Action Inspect Change Clean W = W eekly R = Replace as Necessary M = Monthly * = Notify Deale ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 25

    Section 5 — T roubleshooting Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 5.1 TROU B LE SHOO TI NG GU I DE P ROB LEM CAUSE C OR R E CTION The engine will not crank. 1. F use blown 1. Replace 15A fuse on generator control panel. 2. Loose, corroded or defective 2. Tighten, clean or replace battery cables as necessary . 3. Defective start ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 26

    Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 1 2 & 15 kW – Drawing No. 0D85 00-B TX - TRANSFORMER , 16 Va c 56 V A & 16 Va c 1 V A ( DUAL SEC . ) 0 CUS T O MER SU PPLIE D BLA CK BATTERY 12 V L OP HT O 0 S P 2 S P 1 IM2 86 85 IM1 D D DIA G RAM KE Y D S W - P C B M OU NTED DIP S WI ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 27

    Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Wiring Diagram – 1 2 & 15 kW – Drawing No. 0D85 00-B C L OS E S T T O BEARIN G G R D 0 4 S TAT OR 1 94 224 224 22 5 1 5 224 17 4 22 5 224B 22 5 0 0 OU TP U T T O TRAN S FE R 22 22 MAN U A L F2 0 1 5A 66A 2 39 1 3 1 5 1 3 1 3 0 F1 1 5 17 17 V O LTA GE RE GU ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 28

    Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 1 2 & 1 5 kW – Drawing No. 0D85 0 1 -B IM1 - IGNITION MODULE , CYLINDER # 1 IM2 - IGNITION MODULE , CYLINDER # 2 L O P - L O W O IL PRE SSU RE S WIT CH SP1 , SP2 - SPARK PLUG S S W1 - A U T O / O FF / MAN U AL S WIT CH S W2 - S ET EX ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 29

    Section 6 — Electrical Data Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Electrical Schematic – 1 2 & 1 5 kW – Drawing No. 0D85 0 1 -B 2 39 IM2 1 5 1 8 S P 2 24 0 V IM1 0 1 94 17 1 5 2 3 1 5 2 39 S W 1 1 94 1 5A 22 11 2 3 11 22 11 S P 1 44 WINDIN G 12 0 V 12 0 V 33 NEUTRAL N2 N1 2 3 CUS T O ME R CO NNE C TI O N S 1 94 0 0 SC F ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 30

    TX - TRANSFORMER , 16 Va c 56 V A & 16 Va c 1 V A ( DUAL SEC . ) CB2 - CIRCUIT BREAKER , ALTERNATOR EXCITATIO N BLA CK CUS T O MER SU PPLIE D BATTERY 12 V L OP HT O SP 86 85 IM D D S W - P C B M OU NTED DIP S WIT CH C B1 - MAIN OU TP U T BREAKE R BA - BR US H A SS EMBL Y B C R - BATTERY C HAR G E RELA Y D - DI O D E SC - S TARTER CO NTA C T OR ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 31

    0 4 C L OS E S T T O BEARI N G R D S TAT OR OU TP U T T O TRAN S FE R 24 0 V G ENERAT OR S WIT C H CO NTA C T OR 8 2 0 66A 1 94 1 5 0 66A 1 5A 2 39 2 3 1 5 1 5A F2 1 3A 1 3 0 1 3 F1 1 3 351 14 N2 0 22 4 22 5 0 351 1 3 224 4 0 22 5 14 N2 N1 1 3A N1 V O LTA GE RE GU LAT OR 0 66A 0 1 62 2 2 0 4 6 11 4 4 11 2 2 4 MAN U A L A U T O 1 7 1 5 S W 1 2 39 S ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 32

    CB1 - CIRCUIT BREAKER , MAIN OUTPU T HT O - HI G H O IL TEMPERAT U RE S WIT CH S W1 - A U T O / O FF / MAN U AL S WIT CH CB2 - CIRCUIT BREAKER , ALT . EXCITATIO N TX - TRANSFORMER , 16 Va c 56 V A & 16 Va c 1 V A ( DUAL SEC . ) B C R - BATTERY C HAR G E RELA Y BA - BR US H A SS EMBL Y F1 - F US E 1 5 AM P F2 - F US E 5 AM P S P - S PARK PL UG F ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 33

    INP UT 12 V d c U TILIT Y CO I L RELAY TRAN S FE R NE U TRA L 120 V 24 0 V A C CUS T O ME R SU PPLIE D 2 3 S W 1 2 39 C 1- 6 0 1 5 17 0 1 8 C 1- 5 0 1 8 0 17 56 1 8 14 1 5A 17 0 1 5 0 C 1- 1 56 2 39 1 3 1 5 SC 14 1 5A 1 94 2 3 1 5 IM 0 D BLA CK SP P O WE R WINDIN G ( STATOR ) F S 14 C 1- 2 1 94 22 RED SC SM 24 0 V 44 11 C B 1 33 12 0 V C 2- 5 N2 22 ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 34

    2 3 36 24 37 4 9 35 2 6 4 6 4 9 2 4 3 4 9 4 3 32 34 1 8 50 7 4 35 25 51 1 5 4 8 21 1 90 91 93 1 3 42 39 1 0 3 93 2 5 35 14 88 54 9 8 27 35 1 49 4 9 11 50 1 6 17 1 5 47 1 9 12 6 31 44 30 2 9 2 8 87 86 41 4 0 55 57 56 58 52 49 20 52 72 60 44 62 64 66 59 71 69 68 71 68 69 38 7 3 7 5 4 6 7 4 76 82 77 80 82 7 9 80 81 4 8 44 85 84 72 91 63 92 4 9 PRE PA ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 35

    ITEM P ART NO .QTY . DESCRIPTION 1 0C6140 1 ASS E M B LY, E N CLO S U R E B AS E 0D1 9 01 1 ASS E M B LY, E N CLO S U R E B AS E (7K W ) 2 0C67 3 52 S UPPO R T, R OOF FOLDI N G 3 0C7061 1 E N CLO S U R E, F R O N T 4 0C7062 1 E N CLO S U R E, EXH A U S T S IDE 0C7062 A 1E N CLO S U R E, EXH A U S T S IDE (7K W ) 5 0C706 3 1E N CLO S U R E, S IDE &a ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 36

    31 19 3 7 38 22 8, 9 27 45 46 44 48 47 10 3 49 35 13 17 5 21 35 23 49 29 21 17 4 2 38 6 7 2 20 27 15 40 41 39 4 5 44 43 1 30 15 11 47 4 5 24 45 47 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Control Panel – Drawing No. 0E7 97 4-C 34 Generac ® Pow er Systems, Inc. ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 37

    ITEM P ART NO . QTY . DESCRIPTION 1 0E7886 A 1C I R CUIT B R E A KE R 3 0 A X 2P 240V (7K W ) 0E7886C 1 CI R CUIT B R E A KE R 40 A X 2P 240V (8.5K W ) 0E7886D 1 CI R CUIT B R E A KE R 45 A X 2P 240V (11K W ) 0E7886E 1 CI R CUIT B R E A KE R 50 A X 2P 240V (12K W ) 0E7886F 1 CI R CUIT B R E A KE R 60 A X 2P 240V (1 3 K W ) 0E7886G 1 CI R CUIT B R E ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 38

    1 4 3 53 46 48 47 49 50 5 1 5 2 40 38 42 45 44 43 29 143 3 7 26 3 24 1 4 0 3 2 35 55 33 36 20 5 7 58 59 6 1 60 6 4 6 2 63 65 1 2 6 3, 32 , 33 , 34 , 35 , 36 , 40 , 72 2 7 , 28 , 29 2, 5 , 19 , 20 , 39 , 40 , 47 , 64 , 93 , 140 16B 56 54 23 25 30 16 A 3 4 3 4 15 16 A 17 18 22 71 73 72 66 8 14 13 12 10 7 9 4 5 Section 7 — Exploded Views and P arts ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 39

    ITEM P ART NO . QTY . DESCRIPTION 1 0C572 9 1 ASS E M BL Y , C RAN KC AS E HOU S I N G W ITH S LEEVE 20 C 3 008 1 S E A L, 3 8 I.D . C RAN K S H A FT 3 0 9 0 3 88 3S C R E W , T A PTITE M 6-1.0 X 12 YC 4 0C5 3 72 1 ASS E M BL Y , B R E A THE R 50 C 3 005 1 G AS KET , B R E A THE R CO VE R 60 E 33 72B 3S EP ARA TO R , OIL B R E A THE R 7 0D8067 A 1 ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 40

    1 112 8 11 0 1 33 91 84 88 87 86 89 85 90 89 74 80 83 81 7 9 11 102 99 92 1 01 11 3 112 1 05 1 07 1 08 103 111 141 1 09 12 5 123 , 14 5 96 95 14 3 1 30 114 7 5 7 8 77 7 6 99 11 8 8 97 121 124 124 11 9 122 12 5 1 37 12 0 127 12 6 11 5 11 6 1 36 1 38 32 142 2 9 1 34 1 39 1 35 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 41

    ITEM P ART NO . QTY . DESCRIPTION 74 0C51 3 6 A 2K N OB , A I R CLE AN E R 75 0C 3 024 1 CO VE R , A I R BO X N G/LP 76 0C 3 040 1 P R E-CLE AN E R , 77 0C8127 1 ELE M E N T, A I R CLE AN E R 78 0D8564 A 1 ASS E M BL Y , M IXE R / A I R BO X 99 0 0D8564B 1 ASS E M BL Y , M IXE R / A I R BO X 760 7 9 0D25 9 54 S C R E W S HOULDE R (8 MM ) M 6-1.0 X ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 42

    5 1 23 11 5 3 1 21 53 7 30 13 33 5 2 1 38 3 2 17 28 3 1 3 1 20 14 19 10 17 15 32 2 10 19 16 39 8 6 3 3 2 3 4 30 40 46 45 47 36 1 3 2 4 25 26 34 3 4 48 10 28 27 28 3 2 3 1 18 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 7 kW Generator – Drawing No. 0D35 04-D 40 Generac ® Pow er Systems, Inc ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 43

    Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 7 kW Generator – Drawing No. 0D35 04-D ITEM P ART NO . QTY . DESCRIPTION 1 0C6 93 41 A D A PT O R , E N GI N E 20 C 993 5H 1 S T A TO R 3 0C 993 4H 1 R OTO R 4 0C604 3A 1C ARR IE R , R E AR BE AR I N G 5 0C80 9 61 F AN , 8" CU R VED BL A DE ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 44

    29 3 4 11 2 5 24 43 21 7 13 33 12 38 17 3 2 3 1 28 3 1 20 19 10 17 15 32 16 22 39 8 6 37 14 3 2 40 1 32 24 25 10 30 19 26 28 27 28 3 2 3 1 41 10 18 36 8 35 29 36 36 35 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1 2 kW and 1 5 kW Generator – Drawing No. 0D3 4 1 7-J 42 Generac ® Pow er Sys ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 45

    Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators 1 2 kW and 1 5 kW Generator – Drawing No. 0D3 4 1 7-J ITEM P ART NO . QTY . DESCRIPTION 1 0C6 93 41 A D A PT O R , E N GI N E 2 0C7 93 01 S T A TO R 12K W 0D2 3 5 9S T A TO R 1 3 K W / 15K W 3 0C7 9 44 1 R OTO R 12K W 0D2 3 56 R OTO R 1 3 K W / 1 ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 46

    3 2 23 3 4 35 36 45 39 33 20 19 18 43 44 46 11 4 9 29 3 7 2 7 28 30 3 1 17 5 2 47 48 24 38 26 22 40 41 25 25 50 14 12 5 1 13 5 4 16 1 6 1 2 11 10 4 2 5 7 9 8 3 4 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GN4 1 0 Engine – Drawing No. 0E9 1 80-A Part 1 44 Generac ® Pow er Systems, Inc. ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 47

    ITEM P ART NO . QTY . DESCRIPTION 10 E 3 221 1 ASS E M BL Y , CO NN ECTI N G R OD 2 0E1466 1 PI N , PI S TO N D20 3 0215 33 1 S ET , PI S TO N R I N G 9 0 MM 40 E 2 9 85 1 PI S TO N , HC 5 071 9 8 3 2 R ET A I N E R , PI S TO N PI N 20 6 0E8440 1 ASS E M BL Y , C RAN K S H A FT GH410 SMA LL T A PE R 70 A 7628 1 ARM , GO VE RN O R R C45 8 078658 1 P ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 48

    19 20 41 42 21 6 40 3 39 28 24 6 12 7 6 6 6 14 18 17 16 15 3 1 30 27 2 45 5 29 13 8 10 11 9 18 18 25 3 2 3 4 1 33 3 4 4 6 36 3 7 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GN4 1 0 Engine – Drawing No. 0E9 1 80-A Part 2 46 Generac ® Pow er Systems, Inc. ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 49

    ITEM P ART NO . QTY . DESCRIPTION 1 0C106 9 5 S C R E W , T A PTITE M 6-1.0X8 YELLO W CH R O M E 2 0D2 9 22 1 HOU S I N G, BLO W E R 3 0C84 3 5 1 TUBE, DIP S TICK 40 C 999 71 G U AR D, F AN 5 0884 3 41 WRA PPE R , BO TT O M 6 045756 11 S C R E W , T A PTITE M 6-1X10 YELLO W CH R O M E 7 0C4176 A 1 WRA PPE R , T OP 80 D 9 004 A 1 ASS Y, S T AR TE R ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 50

    1 2 5 4 10 3 6 7 8 12 11 28 26 15 14 17 1 3 22 2 3 24 25 1 9 20 18 2 9 16 21 3 1 18 2 9 16 26 14 15 17 1 3 21 20 1 9 24 22 25 2 3 10 9 28 11 12 27 3 7 3 5 3 2 10 33 3 4 3 7 3 6 FO R GT 760 E N GI N E O N LY 3 2 Section 7 — Exploded Views and P arts Lists Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Gas Regulator – Drawing No. 0D8 7 2 ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 51

    ITEM P ART NO . QTY . DESCRIPTION 1 0D56 9 41 C AS TI N G, T W I N R EGUL A TO R HOU S I N G 2 0C5765 1 S OLE N OID , T W I N R EGUL A TO R 3 0C4647 1 G AS KET , S OLE N OID 4 0C4680 1 PLU N GE R , LP R EGUL A TO R ASS E M BL Y 5 0C6070 1 S P R I N G- S OLE N OID , PLU N GE R 6 022 9 85 4 WA S HE R , FL A T # 6 7 022264 4 WA S HE R , LOCK M 4 8 075 ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 52

    Section 8 — Mounting Dimensions Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Drawing No. 0D3 7 3 9-B T M6PEM-T M6P M6PEM PE REAR VIEW L EFT S IDE VIEW TRANSFER SWITCH R I G HT S IDE VIE W F R O NT VIEW AIR NTAKE ( IF SUPPLIED ) " D O N O T LIFT BY THE R OO F" L IFTIN G H O LE S 4- CO RNER S Ø 3 0.2mm [ Ø 1 .19" ] R OU ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 53

    Section 9 — Notes Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators Generac® Pow er Systems, Inc. 51 ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 54

    Section 1 0 – W arranty Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators NOTE: This Emission Control W arranty Statement pertains to this product only IF the generator size is 15 kW or below . CALIFORNIA AND FEDERAL EMISSION CONTR OL W ARRANTY ST A TEMENT Y OUR W ARRANTY RIGHTS AND OBLIGA TIONS The California Air Resources Board (CARB) and ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 55

    Section 1 0 – W arranty Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators EMISSION CONTROL SYSTEM W ARRANTY Emission Control System Warranty (ECS W arranty) for 1997 and later model year engines: (a) Applicability: This warranty shall apply to 1997 and later model year engines. The ECS Warranty Period shall begin on the date the new engine ...

  • Generac Power Systems 04758-1, 04759-1, 04760-1 - page 56

    Part No. 0E8295 Revision F (04/06/04) Printed in U.S.A. Section 1 0 – W arranty Guardian Air-cooled 7 kW , 1 2 kW and 1 5 kW Generators GENERA C PO WER SYSTEMS “TW O YEAR” LIMITED W ARRANTY FOR GU ARDIAN ® “PREP A CKA GED EMERGENCY A UTOMA TIC ST ANDBY GENERA TORS” F or a period of two years from the date of original sale, Generac P ower ...

Fabbricante Generac Power Systems Categoria Portable Generator

I documenti che otteniamo dal fabbricante del dispositivoGenerac Power Systems 04758-1, 04759-1, 04760-1 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Generac Power Systems
- manuali per l’uso 04758-1, 04759-1, 04760-1
- schede prodotto Generac Power Systems
- opuscoli
- o etichette energetiche Generac Power Systems 04758-1, 04759-1, 04760-1
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Generac Power Systems 04758-1, 04759-1, 04760-1.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Generac Power Systems 04758-1, 04759-1, 04760-1, manuali di manutenzione, brevi manuali o manuali utente Generac Power Systems 04758-1, 04759-1, 04760-1. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Generac Power Systems 04758-1, 04759-1, 04760-1.

Manuale completo del dispositivo Generac Power Systems 04758-1, 04759-1, 04760-1, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Generac Power Systems 04758-1, 04759-1, 04760-1 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Generac Power Systems 04758-1, 04759-1, 04760-1.

Il manuale per l’uso completo Generac Power Systems, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Generac Power Systems 04758-1, 04759-1, 04760-1 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Generac Power Systems 04758-1, 04759-1, 04760-1, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Generac Power Systems 04758-1, 04759-1, 04760-1 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Generac Power Systems 04758-1, 04759-1, 04760-1 - che ci dovrebbe aiutare nei primi passi durante l'uso Generac Power Systems 04758-1, 04759-1, 04760-1
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Generac Power Systems 04758-1, 04759-1, 04760-1
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Generac Power Systems 04758-1, 04759-1, 04760-1 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Generac Power Systems 04758-1, 04759-1, 04760-1?

Utilizza il modulo sottostante

Se non hai risolto il problema con Generac Power Systems 04758-1, 04759-1, 04760-1 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Generac Power Systems 04758-1, 04759-1, 04760-1 è probabile che voglia condividere il modo di risolverlo.