    309362 Re v . E Related manuals U.S. Patent Pending . . 309342 309092, 308438 . . . . . . . 309340 . . . . . . . .. 307049 OPERA TION Zinc Sprayer List of Models, page 2 For Maximum Working Pressure see page 2 INSTRUCTIONS IMPORTANT W ARNINGS AND INFORMA TION. Read and keep for reference. GRACO INC. P .O. BOX 1441 MINNEAPOLIS, MN 55440–1441 E COP ...

  • Graco Inc. 245116 - page 2

    2 309362 List of Models HD = Heavy Duty Cart L W = Light Weight Cart Part No. Series Ratio / Pump Pump No. Gun Hose HD LW Maximum Fluid Working Pressure Maximum Air Input Pressure 244463 A 33:1 Bulldog 2451 17 X X X 20.7 MPa (207 bar) (3000 psi) .7 MPa (7.0 bar) (100 psi) 2451 13 A 24:1 Bulldog 2451 16 X X X 23.4 MPa (234 bar) (3400 psi) .7 MPa (7. ...

  • Graco Inc. 245116 - page 3

    3 309362 Symbols When you see a symbol in the manual, for example refer to the W ARNINGS on pages 3–4. W ARNING INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result in serious injury . D Read all instruction manuals, tags, and labels before operating the equipment. ...

  • Graco Inc. 245116 - page 4

    4 309362 Symbols W ARNING FIRE AND EXPLOSION HAZARD Solvent and paint fumes can ignite or explode. T o help prevent a fire and explosion: D Ground the equipment and the object being sprayed. See Grounding on page 7. D Use in extremely well ventilated area. D Hold gun firmly to side of grounded pail when triggering into pail. D Use only electrically ...

  • Graco Inc. 245116 - page 5

    5 309362 ...

  • Graco Inc. 245116 - page 6

    6 309362 Overview Pump Air Regulator ON OFF 1 2 3 Loosen nut Tighten nut Adjust Air Air Supply V alve (Must be Bleed T ype) Grounding Wire Return System ...

  • Graco Inc. 245116 - page 7

    7 309362 Grounding Use only electrically conductive hoses. 1. Connect ground wire clamp to a true earth ground. 2. Ground object being sprayed, fluid supply containers, solvent pails, waste pails, and all other equipment in spray area. Use only metal pails. Do not place on non-conductive surface such as paper , cardboard, or plastic. P AINT TINT A ...

  • Graco Inc. 245116 - page 8

    8 309362 Setup Complete before using the equipment for the first time. 1. 2. 3. 4. 5. T ools Required: 1. T wo adjustable wrenches 2. Non–sparking hammer or plastic mallet 3. T orque wrench 4. Grounding wires and clamps for pails 5. T wo 5 gallon metal pails 1. Ground sprayer . See page 7. 2. Check packing nut. Fill with Throat Seal Liquid (TSL). ...

  • Graco Inc. 245116 - page 9

    9 309362 Setup 3. Attach electrically conductive fluid hose to pump and tighten. 4. Attach electrically conductive fluid hose to gun and tighten. 5. Connect main air supply to air supply valve. 6. Flush. See page 1 1. FLUSH W ASTE 7. Prime. See page 14. W ASTE P AINT ...

  • Graco Inc. 245116 - page 10

    10 309362 Pressure Relief Follow steps 1–3 when you stop spraying and before cleaning, checking, or servicing the equipment. 1. Close bleed type air supply valve. 2. Hold gun firmly against a grounded metal pail and trigger gun. 3. Open return valve. ...

  • Graco Inc. 245116 - page 11

    11 309362 Flush Flush before using for the first-time, changing colors, before fluid can dry or settle out, and before storing the system. 1. Relieve pressure. See page 10. 2. Remove tip and guard. ...... 309092, 308438 TI1 114 3. Place suction tube in solvent. FLUSH ...

  • Graco Inc. 245116 - page 12

    12 309362 Flush 4. Adjust air regulator by turning handle counter–clockwise. 5. Open air valve. Always use lowest air pressure possible when flushing. 6. Flush hose and gun. W ASTE 309092, 308438 . . . . . . . 7. Put recirculation tube in a grounded w a s te p a i l . Slowly open return valve. W ASTE ...

  • Graco Inc. 245116 - page 13

    13 309362 Flush 8. When clean solvent flows from tube, close return valve. Pump will stall. W ASTE 9. Relieve pressure. See page 10. TI1217 10. Store sprayer with solvent inside, or prime with another fluid to continue spraying. ...

  • Graco Inc. 245116 - page 14

    14 309362 Prime 1. Shut off bleed type air supply valve. 2. Adjust air regulator by turning handle counter–clockwise. 3. Replace tip and guard. ...... 309092, 308438 TI1 114 4. Place suction tube in fluid. P AINT ...

  • Graco Inc. 245116 - page 15

    15 309362 Prime 5. Place recirculation tube in a grounded fluid pail. Open return line valve. P AINT 6. Open air valve. 7. Adjust air regulator by turning handle clockwise until pump starts. Use lowest air pressure to run pump. ...

  • Graco Inc. 245116 - page 16

    16 309362 Prime 8. Close return valve when material starts flowing. 9. Hold gun firmly against a grounded metal pail and trigger gun until fluid flow is steady . Release trigger . Place recirculation tube into fluid to be sprayed. Equip- ment is ready to spray . ....309092, 306686, 308438 ...

  • Graco Inc. 245116 - page 17

    17 309362 Spraying 1. Replace tip and guard. TI1 114 2. Set air pressure regulator . 3. Slowly open bleed type air valve. 4. T est spray pattern. Read fluid manufacturer ’s recommendations. Adjust as necessary . . . 309092, 306686, 308438 ...

  • Graco Inc. 245116 - page 18

    18 309362 Spraying 5. When not spraying, reduce air pressure to 30 psi. Open recir- culation tube and close gun valve. P AINT 6. Flush and relieve pressure when done spraying. See page 10 and 1 1. ...

  • Graco Inc. 245116 - page 19

    19 309362 Maintenance Daily 1. FLUSH 2. Relieve pressure. See page 10. 3. Check packing nut. Adjust packings and replace TSL as necessary . T orque to 25–30 ft–lb (34–41 N S m). ...

  • Graco Inc. 245116 - page 20

    20 309362 Maintenance 4. Drain water from air filter . 5. Clean suction tube using a compatible solvent. Clean outside of sprayer using a cloth and compatible solvent. ...

  • Graco Inc. 245116 - page 21

    21 309362 Maintenance 6. Check hoses, tubes, and cou- plings. T ighten all fluid connec- tions before each use. T roubleshooting . . . 309340 ...

  • Graco Inc. 245116 - page 22

    22 309362 Dimensions (For mounting hole layout see air pump manual ) A B C Pump Model A mm (in.) B mm (in.) C mm (in.) Weight (approx.) kg (lbs) Bulldog 33:1 1257 (49.5) 795 (31.3) 660 (26) 236 (107) Bulldog 24:1 1257 (49.5) 795 (31.3) 660 (26) 236 (107) ...

  • Graco Inc. 245116 - page 23

    23 309362 ...

  • Graco Inc. 245116 - page 24

    24 309362 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by a n authorized Graco distributor to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for ...

Fabbricante Graco Inc. Categoria Paint Sprayer

I documenti che otteniamo dal fabbricante del dispositivoGraco Inc. 245116 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Graco Inc.
- manuali per l’uso 245116
- schede prodotto Graco Inc.
- opuscoli
- o etichette energetiche Graco Inc. 245116
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Graco Inc. 245116.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Graco Inc. 245116, manuali di manutenzione, brevi manuali o manuali utente Graco Inc. 245116. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Graco Inc. 245116.

Manuali per l’uso simili

Manuale completo del dispositivo Graco Inc. 245116, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Graco Inc. 245116 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Graco Inc. 245116.

Il manuale per l’uso completo Graco Inc., dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Graco Inc. 245116 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Graco Inc. 245116, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Graco Inc. 245116 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Graco Inc. 245116 - che ci dovrebbe aiutare nei primi passi durante l'uso Graco Inc. 245116
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Graco Inc. 245116
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Graco Inc. 245116 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Graco Inc. 245116?

Utilizza il modulo sottostante

Se non hai risolto il problema con Graco Inc. 245116 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Graco Inc. 245116 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)