Manuale per l’uso Master Lock E72

21 pagine 0.48 mb
Scarica

Vai alla pagina of 21

Summary
  • Master Lock E72 - page 1

    M:INSINST -E72 Prog. Guide 0701 Visit our website for more information on our complete product line, new product announcements, pricing , installation instructions and templates. www .sdcsecurity .com ...

  • Master Lock E72 - page 2

    For T echnical Support Contact: Introduction Page i Congratulations, you have just purchased the E72 EntryCheck by SDC , the most advanced stand-alone door lock and access control system on the market today . The lock, designed for easy installation, will pro- vide years of reliable service when properly installed and maintained. This manual is des ...

  • Master Lock E72 - page 3

    Before Y ou Begin Page iii KEYP AD INFORMA TION The E72 EntryCheck keypad has two special k eys: the T erminator and the Programming k ey . • T erminator - This key functions lik e the “enter ” k ey on a computer . Once the terminator is pressed, the information entered is saved. The default terminator key for the E72 is “*”. • Programm ...

  • Master Lock E72 - page 4

    RESETTING THE E72 There may be a time when you need to fully reset your E72 and start over . If you reset the E72, all previous information in the lock memory will be lost. (This includes: users, scheduling, GGM code, E72 ID and lock settings.) Here are the steps to perform a full reset. 1. Remove batteries. 2. W ait approximately 5 minutes to allo ...

  • Master Lock E72 - page 5

    Function 03 Add Group Schedule Page vii Day Code Sample Function P rogramming P age V alid User Code Function 03 Group Schedule Level: Master Function schedules OPEN and CLOSE time/day for an established GROUP of users. This function differs from the Basic Schedule (Func. 02) , in that specific GROUPS can be granted access. (Military) Hours Minutes ...

  • Master Lock E72 - page 6

    Factory Code * 9991234 PIN Initialize Great Grand Master Page 2 IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT . BEGIN AT STEP 1. 3 to 6 Alpha-Numeric # Level: Master When the Great Grand Master (GGM) is entered it has the two components that are found in all codes. 1. User ID (UID) 3 to 4 DIGITS 2. Pin Number (PIN) 3 to 6 DIGITS/AL ...

  • Master Lock E72 - page 7

    V alid User Code Level: Master DA TE MUST BE SET PRIOR T O ACTIVA TING SCHEDULING. This function SETS the MONTH, DA Y , YEAR and DA Y OF THE WEEK. Function Number 3 * Note DA TE MUST BE SET PRIOR TO ACTIV A TING SCHEDULING. The DEFAUL T for this function is MM/DD/YY . AL TERNATE D A TE FORMAT can be used by entering: DD/MM/YY “0” “ * ”. ENT ...

  • Master Lock E72 - page 8

    Close Time (Military) Hours Minutes * See Day Code Mgmt. Defined V alid User Code Basic Schedule Function 02 Page 6 IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT . BEGIN AT STEP 1. Level: Master The BASIC SCHEDULE function is a powerful tool that recognizes those scheduling TIMES that GROUPS have in COMMON . It was designed to give ...

  • Master Lock E72 - page 9

    V alid User Code See Day Code Mgmt. Defined User Schedule Function 04 Page 8 IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT . BEGIN AT STEP 1. Level: Master Function schedules OPEN and CLOSE time/day for INDIVIDUAL user . This function is intended to work in conjunction with an existing group schedule. Ex. User “ A” belongs to g ...

  • Master Lock E72 - page 10

    Mgmt. Defined Month Day Mgmt. Defined Month Day Mgmt. Defined (Up to 4 Digits) # V alid User Code End Date * T emporary User Schedule Function 06 Page 10 IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT . BEGIN AT STEP 1. Level: Master Function allows an existing USER to be flagged as a TEMPORARY USER. The TEMPORARY USER will function ...

  • Master Lock E72 - page 11

    V alid User Code User Defined See Note User Defined New PIN Number Change User PIN Function 08 Page 12 IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT . BEGIN AT STEP 1. Level: User Function allows the USER to CHANGE their PIN . The change user PIN function adds overall security to the locks by allowing users to change a compromised ...

  • Master Lock E72 - page 12

    Function Number 0 * V alid User Code Deny/R estore Access T o Selected Groups Function 10 Page 14 IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT . BEGIN AT STEP 1. Level: Master This function allows RESTRICTED ACCESS to SELECTED USER GROUPS without erasing the group/groups from memory . Once access has been denied to a group/groups ...

  • Master Lock E72 - page 13

    IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT . BEGIN AT STEP 1. Clear Memory Function 16 Level: Grand Master This function will CLEAR the MEMORY of the lock and/or CLEAR ALL SCHEDULES, D A TE AND TIME. Enter "0" to CLEAR ALL USERS, DA TE , TIME , SCHEDULES & FUNCTIONS. (EX CEPT GGM and LOCK ID .) Enter "1" ...

  • Master Lock E72 - page 14

    IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT . BEGIN AT STEP 1. Define Open Time Function 18 Page 18 V alid User Code 1 to 9 Seconds Level: Master This function SETS the time the lock will REMAIN OPEN to allow access. The time INTERVAL may vary between 1-9 SECONDS . Shorter open times help to prevent tailgating. If user opens the ...

  • Master Lock E72 - page 15

    IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT . BEGIN AT STEP 1. F irst Super visor to Arrive Function 31 Page 20 V alid User Code Level: Grand Master This function will override the set schedule, denying USERS access until a user with a MINIMUM ACCESS OF SUPERVISOR (02-04) enters their code. After a supervisor enters their code, t ...

  • Master Lock E72 - page 16

    IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT . BEGIN AT STEP 1. Function 34 Lock Audio Page 23 V alid User Code Select One: (0) Audio OFF (1) Audio ON Level: Master LOCK AUDIO is designed to give an audio feedback from internal sounding unit. The lock keypad has an audible click which sounds at all times with every keystrok e. Not ...

  • Master Lock E72 - page 17

    Fail Secure Function 36 Page 24 IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT . BEGIN AT STEP 1. V alid User Code Level: Grand Master THIS FUNCTION IS ONLY INTENDED FOR USE IN BA TTERY POWERED UNITS. In case the low battery warning goes unnoticed, (See Battery Information page iv) and the lock runs out of power , this function ensu ...

  • Master Lock E72 - page 18

    Upload Lock Information Function 14 Page 26 IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT . BEGIN AT STEP 1. V alid User Code Level: Security Guard This function will take the information stored in the IDT and upload and update the E72’s memory . Any changes made at the door via the keypad and not updated in the computer will be ...

  • Master Lock E72 - page 19

    Lock Upgrade Function 20 Page 28 IF ERROR ON ENTRY OR NO ENTRY IN 5 SECONDS, LOCK WILL TIME-OUT . BEGIN AT STEP 1. V alid User Code Level: Master This function is used to upgrade the memory of your E72. Here are the steps. 1. Obtain the lock serial number . The serial number is printed on the exterior backplate of the E72. Or , using the IDT , the ...

  • Master Lock E72 - page 20

    Military Time Conversion Chart P rogramming Category Maximum Quantities* Page 30 Standard Time Military T ime 1:00 a.m..................................0100 2:00 a.m..................................0200 3:00 a.m..................................0300 4:00 a.m..................................0400 5:00 a.m..................................0500 6:00 ...

  • Master Lock E72 - page 21

    Access, Deny/Restore to Selected Groups, F unction 10.........14 Access Level, Set, Function 11 ............................................15 Alternative T erminator , F unction 37.......................................25 Audio, Lock, Function 34 ......................................................23 Audit T rail, Download, Function 5........... ...

Fabbricante Master Lock Categoria Door

I documenti che otteniamo dal fabbricante del dispositivoMaster Lock E72 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Master Lock
- manuali per l’uso E72
- schede prodotto Master Lock
- opuscoli
- o etichette energetiche Master Lock E72
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Master Lock E72.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Master Lock E72, manuali di manutenzione, brevi manuali o manuali utente Master Lock E72. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Master Lock E72.

Manuali per l’uso simili

Manuale completo del dispositivo Master Lock E72, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Master Lock E72 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Master Lock E72.

Il manuale per l’uso completo Master Lock, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Master Lock E72 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Master Lock E72, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Master Lock E72 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Master Lock E72 - che ci dovrebbe aiutare nei primi passi durante l'uso Master Lock E72
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Master Lock E72
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Master Lock E72 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Master Lock E72?

Utilizza il modulo sottostante

Se non hai risolto il problema con Master Lock E72 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Master Lock E72 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)