Manuale per l’uso SPX Cooling Technologies Marley Sigma Steel

28 pagine 1.32 mb
Scarica

Vai alla pagina of 28

Summary
  • SPX Cooling Technologies Marley Sigma Steel - page 1

    / Mar le y Sigma St eel Cooling T ower / Engineer ing Data & Specifications ...

  • SPX Cooling Technologies Marley Sigma Steel - page 2

    ...

  • SPX Cooling Technologies Marley Sigma Steel - page 3

    Mar ley / Sigma St eel Cooling T ower / T able of Contents Engineer ing Data Sc hematic 6 Support 7 Concrete Basin 8 Piping 9 Environmental 1 0 Energy Management 1 1 Specifications / Base Base 12 Thermal P erformance 13 Construction 1 4 Fan Dec k and F an Cylinder 15 Mec hanical Equipment 15 Fill, Louvers and Drift Eliminator s 17 Hot W ater Distri ...

  • SPX Cooling Technologies Marley Sigma Steel - page 4

    ...

  • SPX Cooling Technologies Marley Sigma Steel - page 5

    Mar ley / Sigma St eel Cooling T ower / 5 only accomplish the specified thermal performance— but whic h will include normal operation- and mainte- nance-enhancing accessories and f eatures. It will also incorporate those standard materials whic h testing and experience has pro ven to pro vide best results in normal operating conditions. P ages 2 ...

  • SPX Cooling Technologies Marley Sigma Steel - page 6

    Mar ley / Sigma St eel Cooling T ower / Engineer ing D ata : Schematic 6 Use this data for preliminary layouts only . Obtain current drawing from your Marley sales representative. The UPDA TE web-based selection sof tware —available at spxcooling.com—provides Sigma Steel model recommendations based on customer's specific design requiremen ...

  • SPX Cooling Technologies Marley Sigma Steel - page 7

    Mar ley / Sigma St eel Cooling T ower / Engineer ing D ata : Support 7 Plan A SP ACES AT 4'-0" = L 6" W OVERALL OF BASIN SUMP OVERFLOW AIR INLET F ACE AIR INLET F ACE CASED ENDW ALL F ACE CASED ENDW ALL F ACE PRIMARY SUPP ORT BEAM INTERMEDIA TE BEAM N O T E 1 Use this bulletin for preliminary layouts only . Obtain cur - rent drawings ...

  • SPX Cooling Technologies Marley Sigma Steel - page 8

    Mar ley / Sigma St eel Cooling T ower / Engineer ing D ata : Concret e Basin 8 Plan 6" MIN. 5" 6" MIN. 5" ANCHOR BOL TS (SEE NOTE 5) 6" MIN. 6" MIN. A SP ACES A T 4'-0" = L PER CELL CASED ENDW ALL F ACE CASED ENDW ALL F ACE AIR INLET F ACE AIR INLET F ACE SUMP W IN T O IN OF BASIN N O T E 1 Use this bulletin ...

  • SPX Cooling Technologies Marley Sigma Steel - page 9

    Mar ley / Sigma St eel Cooling T ower / Engineer ing D ata : Inlet Piping 9 C C COLUMN AND ANCHOR BOL T TYP . SINGLE CELL D TYP . MUL TICELL C L COLUMN AND ANCHOR BOL T C L F AN C L INLET C L INLET C L F AN C L F MIN REQUIRED CLEARANCE C L E G C OF FLANGE T O BASE OF T OWER COLUMNS (USE FOR ST A TIC LIFT) F AN F ACE OF A DIA INLET FLANGE MARLEY PIP ...

  • SPX Cooling Technologies Marley Sigma Steel - page 10

    Mar ley / Sigma St eel Cooling T ower / Engineer ing D ata: Envir onmental 10 Sound Control Sound produced by a Sigma Steel to wer operating in an un- obstructed en vironment will meet all but the most restrictive noise limitations—and will react fav orably to natural at tenu- ation. Where the tower has been siz ed to operate within an enclosure, ...

  • SPX Cooling Technologies Marley Sigma Steel - page 11

    Mar ley / Sigma St eel Cooling T ower / Engineer ing D ata: Energ y Management 11 Cooling tow ers are usually selected to produce a specific cold water temperat ure at the higher summertime wet-bulb temperatures. During the remainder of the y ear , the cooling tow er is capable of producing much colder w ater . Unless your system will benefit fro ...

  • SPX Cooling Technologies Marley Sigma Steel - page 12

    Specifications Specification V alue Mar ley / Sigma St eel Cooling T ower / Specifications: Base 12 1.0 Base: 1.1  F urnish andinst allan induced-draf t, crossflow -type, field-erected, steel- framed, PVC-fill, industrial-duty cooling tow er of _____ cell(s), as sho wn on Plans. The limiting ov erall dimensions of the tower sha ...

  • SPX Cooling Technologies Marley Sigma Steel - page 13

    Specifications Specification V alue Mar ley / Sigma St eel Cooling T ower / Specifications: Base 13 2.0 Ther mal P erfor mance: 2.1 The tow er shall be capable of cooling _____GPM of waterfrom ____°F to _____°F at adesign entering airwet- bulbtemperature of_____ °F . Thecool - ing to ...

  • SPX Cooling Technologies Marley Sigma Steel - page 14

    Specifications Specification V alue Mar ley / Sigma St eel Cooling T ower / Specifications: Base 14 3.0 Constr uction: 3.1 The tow er shall be capable of with- standing water having a pH of 6.5 to 8.0; a c hloride content (NaCl) up to 300 ppm; a sulfate content (SO 4 ) up to 250 ppm; a calcium content (CaCO 3 ) up to 50 0 ppm; silica (SiO 2 ) up to ...

  • SPX Cooling Technologies Marley Sigma Steel - page 15

    Specifications Specification V alue Mar ley / Sigma St eel Cooling T ower / Specifications: Base 15 4.0 F an Deck and F an Cylinder: 4.1 The fan dec k shall act as a working platform for maintenance personnel. It shall be fabricated of no less than 1 2 gauge steel, and shall be designed for a uniform live load of 60 psf . 4.2  Fancylinders ...

  • SPX Cooling Technologies Marley Sigma Steel - page 16

    Specifications Specification V alue Mar ley / Sigma St eel Cooling T ower / Specifications: Base 16 5.3 Motor shall be located outside the fan cylinder at the fan dec k, and shall be connected to the speed reducer by a tubular stainless steel, dynamically balanced driveshaf t equipped with neo- prene flexible coupling elements. 5.4 A galvaniz ed o ...

  • SPX Cooling Technologies Marley Sigma Steel - page 17

    Specifications Specification V alue Mar ley / Sigma St eel Cooling T ower / Specifications: Base 17 6.0 Fill, Louv ers and Drif t Eliminators: 6.1  Fillshall be lm-type, 1 5 milthick, thermoformed PV C, with louvers formedas partof eac h ll sheet.Fill shall be suspended from st ainless steel str ...

  • SPX Cooling Technologies Marley Sigma Steel - page 18

    Specifications Specification V alue Mar ley / Sigma St eel Cooling T ower / Specifications: Base 18 7.0 Hot W ater Distribution Syst em: 7.1 The mec hanical equipment support/ crossov er pipe shall deliver water to two open hot water basins per cell at the fan deck elev ation. W ater shall exit these basins to the fill by gravity through metering ...

  • SPX Cooling Technologies Marley Sigma Steel - page 19

    Specifications Specification V alue Mar ley / Sigma St eel Cooling T ower / Specifications: Base 19 9.2 The top of the tow er shall be equipped with a sturdy 42" high guardrail sys- tem, complete with top rails, interme- diate rails and toeboards, conforming to OSHA st andards. Guardrails and posts shall consist of 1 .66" O.D . x 1 5 gaug ...

  • SPX Cooling Technologies Marley Sigma Steel - page 20

    Specifications Specification V alue Mar ley / Sigma St eel Cooling T ower / Specifications: Options 20 Control Options Control Syst em: 5.7: Add the following paragraph in the Mechanical Equipment section: Eac h cell of the cooling tower shall be equipped with a UL listed control system in a NEMA 3R or 4X outdoor enclosure capable of controlling si ...

  • SPX Cooling Technologies Marley Sigma Steel - page 21

    Specifications Specification V alue Mar ley / Sigma St eel Cooling T ower / Specifications: Options 21 Basin Heaters: 10.2 Add the following paragraph in the Cold W ater Basin section: Provide a system of electric immersion heaters and controls for each cell of the tow er to prevent freezing of water in the collection basin during periods of shut- ...

  • SPX Cooling Technologies Marley Sigma Steel - page 22

    Specifications Specification V alue Mar ley / Sigma St eel Cooling T ower / Specifications: Options 22 temperature and cold-fluid temperature on t wo separate lines. The bypass shall include a complete magnetic bypass circuit and with capability to isolate the VFDwhen in thebypass mode. T ransfer to the bypass mode shall be ma ...

  • SPX Cooling Technologies Marley Sigma Steel - page 23

    Specifications Specification V alue Mar ley / Sigma St eel Cooling T ower / Specifications: Options 23 circuitwith capabilit yto isolate the VFD when in the bypass mode. T ransf er to the bypass mode shall be automatic in theeventof VFDfailure orforspecic trip conditions allowing safe transf er of uti ...

  • SPX Cooling Technologies Marley Sigma Steel - page 24

    Specifications Specification V alue Mar ley / Sigma St eel Cooling T ower / Specifications: Options 24 Conv enience and Saf ety Options Stairwa y: 9.3 Replace paragraph 9.3 with the fol- lowing: A 30" wide, 45° steel st air wa y with 8" rise and run, shall be provided at the tower endwall rising from grade (roof) to the fan dec k elev at ...

  • SPX Cooling Technologies Marley Sigma Steel - page 25

    Specifications Specification V alue Mar ley / Sigma St eel Cooling T ower / Specifications: Options 25 Oil Level Sight Glass: 5.4 Replace paragraph 5.4 with the fol- lowing: A galv anized oil gauge and drain line shall extend from the gear reducer to the vicinity of the motor , and shall be equipped with a bronze- bodied oil level sight glass. Misc ...

  • SPX Cooling Technologies Marley Sigma Steel - page 26

    Specifications Specification V alue Mar ley / Sigma St eel Cooling T ower / Specifications: Options 26 Low Noise T ow er: 1.1 Add the following at the end of this paragraph: The cooling tow er shall be quiet operating, and shall produce an ov erall level of sound no higher than ____ dBA at the critical location indicated on the Plans. ■ Sound pro ...

  • SPX Cooling Technologies Marley Sigma Steel - page 27

    Specifications Specification V alue Mar ley / Sigma St eel Cooling T ower / Specifications: Options 27 Service Lif e-Related Customization: ■ Some adver se water conditions, unsatisfactory air quality, and/or pro- cesses that produce corrosive contaminants, may dictate the use of stainless steel for materials of construction in the tower . Refer ...

  • SPX Cooling Technologies Marley Sigma Steel - page 28

    7 4 01 WEST 1 29 STRE ET OVER LAN D P AR K, KANSAS 6 621 3 U N ITE D ST A TES 913 6 64 7 400 spxcooling@spx.com spxcooling.com In the interest of techno logical progr ess, all products are subject to design and/or material change without notice. ©2008 SPX Cooling T ech nologies , Inc. Printed in USA | SSI G- TS-08A ...

Fabbricante SPX Cooling Technologies Categoria Ventilation Hood

I documenti che otteniamo dal fabbricante del dispositivoSPX Cooling Technologies Marley Sigma Steel possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici SPX Cooling Technologies
- manuali per l’uso Marley Sigma Steel
- schede prodotto SPX Cooling Technologies
- opuscoli
- o etichette energetiche SPX Cooling Technologies Marley Sigma Steel
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso SPX Cooling Technologies Marley Sigma Steel.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione SPX Cooling Technologies Marley Sigma Steel, manuali di manutenzione, brevi manuali o manuali utente SPX Cooling Technologies Marley Sigma Steel. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto SPX Cooling Technologies Marley Sigma Steel.

Manuale completo del dispositivo SPX Cooling Technologies Marley Sigma Steel, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare SPX Cooling Technologies Marley Sigma Steel dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti SPX Cooling Technologies Marley Sigma Steel.

Il manuale per l’uso completo SPX Cooling Technologies, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale SPX Cooling Technologies Marley Sigma Steel - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice SPX Cooling Technologies Marley Sigma Steel, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per SPX Cooling Technologies Marley Sigma Steel che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo SPX Cooling Technologies Marley Sigma Steel - che ci dovrebbe aiutare nei primi passi durante l'uso SPX Cooling Technologies Marley Sigma Steel
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del SPX Cooling Technologies Marley Sigma Steel
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio SPX Cooling Technologies Marley Sigma Steel in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su SPX Cooling Technologies Marley Sigma Steel?

Utilizza il modulo sottostante

Se non hai risolto il problema con SPX Cooling Technologies Marley Sigma Steel con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con SPX Cooling Technologies Marley Sigma Steel è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)