    990-1074B 01/2006 User Manual English APC Smart-UPS ® 1000/1500 VA 100/120/230 V A C 750/1000XL VA 120/230 VA C Tower Uninterr uptible Pow er Supply ...

  • APC UPS - page 2

    ...

  • APC UPS - page 3

    1 Introduction American Po w er Con version Corporation (APC) is the leading national and in ternational manufac- turer of state-of-the- art uninterrupt ible power su pplies, redundant switches, powe r man agement soft- ware, an d related equipment. A PC products protect h ard w ar e, softw are, and data from power distur- banc es in b usine ss and ...

  • APC UPS - page 4

    2 Connecting Equipment and Power to the UPS S MART -UPS R EAR P ANEL 230V M OD ELS 120V/100V M ODELS 1. Plug in the b attery conn ector n . 2. Connect equ ip ment to the UPS. Note: Do not connect a la ser printer to the UPS. A laser printer d raws significantl y more power than other type s of equipm ent and may overload the UPS. 3. Add any option ...

  • APC UPS - page 5

    3 B ASIC C ONNE CTORS Serial Port USB Port Power management s oft ware an d interface kits can be used wi th the UPS. Use only interface kits supplied or appro ved by APC. Use the APC supplied cable to connect to the Serial Port. DO NOT use a standard serial interface cable since it is incompatible with the UPS connector. Both Serial a nd USB Ports ...

  • APC UPS - page 6

    4 2: O PERA TION S MART -UPS F RONT P ANEL Power On Power Off Load Battery Charge Online The online LED illuminates when the UPS is supplying utilit y power to the con- nected equipment. If the LED is not lit, the UPS is eit her not turned ON, or is sup- plying battery power. AVR Tri m This LED illuminates to i ndicate the UPS is compensating for a ...

  • APC UPS - page 7

    5 AVR Boost This LED illuminates to indicate the UPS is compensating for a low utility voltage. On Battery When the on batter y power LED is lit the UPS is supplying battery power to the con nected equipment. When on batter y, the UPS sounds an alarm—four beeps ev er y 30 s econds. Overload The LED illuminates and the UPS emits a sustained alar m ...

  • APC UPS - page 8

    6 3: U SER C ONFIGU RAB LE I TEM S N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HU TE SOFTW ARE OR OPTION AL S MA RT S LOT ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S EL EC TABLE C HOICES D ESCRIPTION Automa tic Self-Tes t Every 14 days (336 hours) Every 7 days (168 hours) , On Startup Only, No Self- Test This func tion sets the i ...

  • APC UPS - page 9

    7 N OTE : S ETTINGS ARE MADE THROUGH SUPPLIED P OWER C HU TE SOFTW ARE OR OPTION AL S MA RT S LOT ACCESSORY CARDS . F UNCTION F ACTORY D EFAULT U SER S EL EC TABLE C HOICES D ESCRIPTION Low B attery Warning . PowerChute in terface softw are provide s auto- matic, unatte nded shut- down w hen appr oxi- mately two minute s (by defa ult) of batter y o ...

  • APC UPS - page 10

    8 4: S TO R AG E , M A INTENA NCE , A ND T R ANSPORTING Storage Store the UPS covered and positioned as for proper functioning, in a cool, dry location, with the bat- teries fully charged. At -15 t o +30 ° C (+5 to +86 ° F), charge the UPS battery every six months. At +30 t o +45 ° C (+86 to +113 ° F), ch arge the UPS batter y every three month ...

  • APC UPS - page 11

    9 1500VA Model Step 3 Pull the battery module out of the compartment until t he back of the modu le is flush with th e outer edg es of the UPS. Disconn ect the battery connector. 1000VA Model Step 3 Disconnect the batter y cable termin a ls before re moving t he batt er y module fr om the UP S. Note: The red cable conn ects to the red color- coded ...

  • APC UPS - page 12

    10 R EPL ACING THE B ATTERY M ODULE To replace the battery module, rev erse the directions above for Removin g the Front Bezel and Bat- tery M odule . Disconnecting the Battery for Transport Alway s DISCONNECT THE B ATTERY before shippin g in compliance with U.S. Departm e nt of Tran sportation (DOT) regu lations. The battery m ay re m a in in the ...

  • APC UPS - page 13

    11 5: T ROUBLESHOOTI NG Use the chart belo w to so lve minor Smart-UPS installatio n and operatio n problems. Refer to the APC web site, www.apc.com , for assistance with com ple x UPS problems. P ROBLEM AND P OSSI B LE C AUSE S OLUTION UPS WILL NOT TURN ON Batter y not conn ected prop- erly. Check that the battery conn ector (rear pan el) is fully ...

  • APC UPS - page 14

    12 P ROBLEM AND P OSSI B LE C AUSE S OLUTION T HE OVERLOAD LED IS LIT AND TH E UPS EMITS A SUSTAINED A LARM TONE The UPS is overloaded. The conn ected equi pment exceed s the speci fied “maximu m load” as de- fine d in Specificati ons at the A PC web site , www.apc .com . The alarm remai ns on un til the overload is removed. Discon nect nonesse ...

  • APC UPS - page 15

    13 P ROBLEM AND P OSSIBLE C AUSE S OLUTION UTILITY CIRCUIT BREAKER T RIPS Utility c ircuit breaker trips dur ing norma l operation. 100V mo dels: In orde r to operate a t the full VA rating of the 1 500VA produ ct, the sup plied 15A pl ug must be replaced with a 20 A plug. This change must be pe rforme d by qualif ied serv ice personnel. UPS OPERAT ...

  • APC UPS - page 16

    14 Service If the UPS requires s er vice do not return it to the dealer. Instead, follow these steps: 1. Revi e w th e problems discuss e d in th e Troubleshooti ng section of th i s manual to eliminate com- mon probl ems. 2. If the problem persists, contact APC Customer Service through the APC web s ite, www.apc.com/su pport .  Note the m odel ...

  • APC UPS - page 17

    15 6: R EGULA TOR Y A ND W ARR AN TY I NF ORMA T I ON Regulatory Agenc y Approvals a nd Radio F reque ncy Warnings 230V MODE LS This is a Class A product. I n a dome stic enviro nment this product m ay cause ra dio int erferenc e, in which cas e the u ser ma y be requi red t o take co rrect ive ac - tions . 120V MODE LS This e quipme nt has been te ...

  • APC UPS - page 18

    16 Declaration of Conformity Limited Warranty America n Power Conversi on (APC) warrant s its produ cts to be free from d efects i n materia ls and workmans hip for a period of two years from th e date of pu rchase. Its obli gation und er this warranty is lim ited to repairin g or replac ing, at its own sole o p- tion, any such defecti ve produ cts ...

Fabbricante APC Categoria Power Supply

I documenti che otteniamo dal fabbricante del dispositivoAPC UPS possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici APC
- manuali per l’uso UPS
- schede prodotto APC
- opuscoli
- o etichette energetiche APC UPS
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso APC UPS.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione APC UPS, manuali di manutenzione, brevi manuali o manuali utente APC UPS. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto APC UPS.

Manuali per l’uso simili

Manuale completo del dispositivo APC UPS, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare APC UPS dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti APC UPS.

Il manuale per l’uso completo APC, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale APC UPS - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice APC UPS, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per APC UPS che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo APC UPS - che ci dovrebbe aiutare nei primi passi durante l'uso APC UPS
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del APC UPS
5. FAQ - domande più frequenti