    OUTDOOR GAS FIREPLACE IMPORTANT: Read this owner's manual carefully and completely before trying to assemble, operate, or service this heater . FOR YOUR SAFETY : Do not store or use gasoline or other flammable vapors and liquids in the vici nity of this or any other appliance. WHA T T O DO IF YOU SMELL GAS:  Do not try to light any applianc ...

  • Procom AL500HYLA - page 2

    2 AL058-01 SAFETY INFORMA TION PRODUCT IDENTIFICA TION 1. Check the heater completely and thoroughly fo r damage. DO NOT run a damaged heater . 2. DO NOT alter the heater or operate a heater that has been modified from its original condition. 3. Use only propane gas. 4. Use only vapor with drawal prop ane gas. If any question, contact your LP deale ...

  • Procom AL500HYLA - page 3

    3 AL058-01 INST ALLA TION TOOLS REQUIRED: ● Philips screwdriver ● Wrench Check if you have the items listed below before installation. ● Logs: 10 ● 4 × 14 self-tapping screw: 5 ● M4 × 10 screw: 32 ● M5 × 1 0 s c r e w : 4 ● C o l u m n : 4 ● Log grate: 1 ● Fixing hoop: 1 ● Hex head screw: 2 ● Handle: 1 ● Screen: 4 Caution ...

  • Procom AL500HYLA - page 4

    4 AL058-01 7. Attach the four columns to the burne r plate with M4 × 10 screws provided. Do not tighten at this time. (See FIG .7) INST ALLA TION INSTRUCTIONS Continued Fi g ure 7 -Column installation 5. Install log s 1,2,3,4,5 by inserting each log screw into holes of corresponding grate branch . Make sure e ach log is placed in proper sequence.( ...

  • Procom AL500HYLA - page 5

    5 AL058-01 8. Set the top p anel in place on the columns and secure with M4 × 10 screws provided. Do not tighten at this time. (See FIG .8) 12. From the outer side, use M5 × 10 screws to fasten the fixing hoop on the right and left support. Fasten the other side of the fixing hoop af ter the cylinder is in place. (See FIG .1 1) Note: The installe ...

  • Procom AL500HYLA - page 6

    6 AL058-01 CONNECTING TO GAS SUPPL Y C o n t i n u e d FUEL REQUIREMENTS:  Connect reg ulator/hose with sta ndard 20-pound LP cylinder coupler .  Call the LP gas supplier to inspe ct the cylinder . Do not use a damaged LP gas cylinder .  Do not use LP gas without proper decompression.  Do not connect irregul ar LP gas supply with heater ...

  • Procom AL500HYLA - page 7

    7 AL058-01 11. S piders and insects can nest a nd live in outd oor appliances, especially in the bu rners and orifice s. This will interrupt the normal flow of LP gas to the heater and can be a very dangerous situation. Inspect for insect infiltration of burner/orifice when one of the following occurs: A. The smell of gas along with predomin ating ...

  • Procom AL500HYLA - page 8

    8 AL058-01 PARTS NOT UNDER WARRANTY: Contact authorized dealers of this product or Parts Central if they can't supply original replacement part(s) Call P RO-COM's Parts Department at 1-877-886-5989 for referral information. When calling PRO-COM, have ready  Model number of your heater  The replacement part number ACCESSORIES Purchas ...

  • Procom AL500HYLA - page 9

    9 AL058-01 PARTS LIST HP500MA This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 7 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 AB01001 Top Panel 1 2 AB29001 Mesh Screen 2 3 AB29002 Mesh Screen 2 4 AL002-01 Column 6 5 AL009-01 Burner Fixing Plate 6 ...

  • Procom AL500HYLA - page 10

    10 AL058-01 ILLUSTRATED PARTS BREAKDOWN AL500HYLA ...

  • Procom AL500HYLA - page 11

    11 AL058-01 PARTS LIST HP500MA This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 7 of this manual. KEY NO. PART NUMBER DESCRIPTION QTY. 1 NBY50-200A1 Burner 1 2 NDW-L600×4 Safety Pilot 1 3 AB31002 Safety Pilot Inlet Tube ASM 1 4 NV2020-1217 Control Valve 1 ...

  • Procom AL500HYLA - page 12

    12 AL058-01 ILLUSTRATED PARTS BREAKDOWN AL500HYLA ...

  • Procom AL500HYLA - page 13

    13 AL058-01 This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 7 of this manual. LOGS LIST AL500HYLA KEY NO. PART NUMBER DESCRIPTION QTY. 1 AL057-01 Log 1 1 2 AL057-02 Log 2 1 3 AL057-03 Log 3 1 4 AL057-04 Log 4 1 5 AL057-05 Log 5 1 6 AL057-06 Log 6 1 7 AL057 ...

  • Procom AL500HYLA - page 14

    1 4 AL058-01 LOGS LIST AL500HYLA NANJING PRO-COM ELECTR IC APPLIANCE CO.,LTD. #6 CHUANGYE ROAD, HIGH NEW TECH. ZONE, NANJING, 210061, CHINA PRO-COM T o ll-F r ee number : 1-877-886-5989 ...

Fabbricante Procom Categoria Outdoor Fireplace

I documenti che otteniamo dal fabbricante del dispositivoProcom AL500HYLA possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Procom
- manuali per l’uso AL500HYLA
- schede prodotto Procom
- opuscoli
- o etichette energetiche Procom AL500HYLA
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Procom AL500HYLA.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Procom AL500HYLA, manuali di manutenzione, brevi manuali o manuali utente Procom AL500HYLA. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Procom AL500HYLA.

Manuali per l’uso simili

Manuale completo del dispositivo Procom AL500HYLA, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Procom AL500HYLA dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Procom AL500HYLA.

Il manuale per l’uso completo Procom, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Procom AL500HYLA - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Procom AL500HYLA, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Procom AL500HYLA che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Procom AL500HYLA - che ci dovrebbe aiutare nei primi passi durante l'uso Procom AL500HYLA
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Procom AL500HYLA
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Procom AL500HYLA in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Procom AL500HYLA?

Utilizza il modulo sottostante

Se non hai risolto il problema con Procom AL500HYLA con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Procom AL500HYLA è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)