    BUNN-O-MA TIC CORPORA TION TW TWF POST OFFICE BOX 3227 SPRINGFIELD, ILLINOIS 62708-3227 TELEPHONE: (217) 529-6601 FAX: (217) 529-6644 10510.0000 11/00 © 1990 Bunn-O-Matic Corporation OPERA TING & SER VICE MANU AL BU N N ® ...

  • Bunn TWF - page 2

    Page 2 CONTENTS Introduction ............................................................. 2 Warranty .................................................................. 2 User Notices ............................................................ 3 Electrical Requirements ........................................... 4 Plumbing Requirements ........... ...

  • Bunn TWF - page 3

    Page 3 #00831.0000 ...

  • Bunn TWF - page 4

    Page 4 ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power sour ce until specified in Initial Set-Up. 120V model brewers require 2-wire, grounded service rated 120 volt ac, 15 amp, single phase, 60 Hz. 120/208V model brewers require 3-wire, grounded service rated 120/ 208 volt, 20 amp, single phase, 60 Hz. Electrical Ho ...

  • Bunn TWF - page 5

    Page 5 I NITIAL SET -UP CAUTION – The brewer must be unplugged throughout the initial set-up, except when specified in the instruc- tions. 1. Remove the top lid from the brewer . 2. Rotate the control thermostat knob fully counter clockwise to the “OFF” position and replace the top lid. 3. Insert the funnel (empty) into the funnel rails. 4. P ...

  • Bunn TWF - page 6

    Page 6 ADJUSTING BREW VOLUMES CAUTION - Disconnect the power sour ce from the brewer prior to the removal of any panel for the replacement or adjustment of any component. NOTE: Prior to setting or modifying batch sizes, check that the brewer is connected to water supply , the tank is properly filled, and a funnel and server are in place. 1. Modifyi ...

  • Bunn TWF - page 7

    Page 7 OPERA TING CONTROLS A. TEA/OFF/COFFEE Switch TEA– Placing the switch in the left position allows the start switch to activate a timed brew cycle delivering .5 gallon of tea concentrate and 2.5 gallons of dilution water into the dispenser . OFF – Placing the switch in the center position stops the brew cycle. Stopping a brew cycle after i ...

  • Bunn TWF - page 8

    Page 8 TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic T echnical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only b ...

  • Bunn TWF - page 9

    Page 9 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Brew cycle(s) will not start (cont.) Brew water is not hot Dilution (Iced T ea) cycle will not start 6. Brew Timer A) Iced T ea B) Hot Coffee 7. Brew Solenoid Valve A) Iced T ea B) Hot Coffee 8. Internal Flow control (.195 GPM) (Hot Coffee Only) 1. Limit Thermostat CAUTION - Do not elimin ...

  • Bunn TWF - page 10

    Page 10 TROUBLESHOOTING (cont.) PROBLEM PROBABLE CAUSE REMEDY Dilution (Iced T ea) cycle will not start (cont.) Inconsistent beverage level in dis- penser (Hot Coffee) Consistently high or low beverage level in the dispenser 2. Start Switch 3. Brew T imer (Iced T ea) 4. Brew Solenoid Valve (Iced T ea) 5. Dilution Solenoid Valve 1. Internal Flow Con ...

  • Bunn TWF - page 11

    Page 11 TROUBLESHOOTING (cont.) PROBLEM Consistently high or low beverage level in the dispenser . (cont.) Spitting or excessive steaming Drip-out time too long Dripping from sprayhead PROBABLE CAUSE 2. External Strainer/Flow Control (.750 GPM) 1. Lime Build-up CAUTION - T ank and tank compo- nents should be delimed regularly depending on local wat ...

  • Bunn TWF - page 12

    Page 12 TROUBLESHOOTING (cont.) Water flows into tank continuously (TEA/OFF/COFFEE Switch in the "TEA or "COFFEE" position) Water flows into tank continuously (TEA/OFF/COFFEE Switch in the "OFF" position) Beverage overflows dispenser 1. Brew Timer A) Iced T ea B) Hot Coffee 1. Brew Solenoid Valve A) Iced T ea B) Hot Coffee ...

  • Bunn TWF - page 13

    Page 13 BUNN ® paper filters must be used for proper extraction. A sufficient quantity of fresh tea leaves or coffee should be used for proper extraction. A six-hole (or seven-hole for Mod- els with 90 oz concentrate option) stainless steel sprayhead must be used for proper extraction. The BUNN ® paper filter must be cen- tered in the funnel and ...

  • Bunn TWF - page 14

    Page 14 SERVICE This section provides procedures for testing and replacing various major components used in this brewer should ser vice become necessary . Refer to T roubleshooting for assistance in determining the cause of any problem. WARNING - Inspection, testing, and repair of electri- cal equipment should be performed only by qualified ser vic ...

  • Bunn TWF - page 15

    Page 15 Location: Viewing the brewer from the, rear the hot coffee brew solenoid valve is mounted on the left side of the mounting bracket. Test Procedures: 1. Disconnect the brewer from the power sour ce. 2. Disconnect the white/red and white/green wires from the hot coffee solenoid valve. With the TEA/ OFF/COFFEE switch in the "COFFEE" ...

  • Bunn TWF - page 16

    Page 16 P2198.50 FIG. 4 ICED TEA BREW SOLENOID V AL VE Location: Viewing the brewer from the rear, the iced tea brew solenoid valve is mounted in the center of the mount- ing bracket. Test Procedures: 1. Disconnect the brewer from the power sour ce. 2. Disconnect the white/violet and white/blue wires from the iced tea brew solenoid valve. With the ...

  • Bunn TWF - page 17

    Page 17 ...

  • Bunn TWF - page 18

    Page 18 Location: The timer is located inside the hood on the left side. Test Procedure. NOTE: Do not remove or install wires while timer board is installed. Pressure applied to one side may cause damage to the board. 1. Disconnect the brewer from the power source and remove the front access panel. 2. Remove the two #8-32 screws securing circuit bo ...

  • Bunn TWF - page 19

    Page 19 TL1 - WHI/RED to Hot Coffee Solenoid and WHI/RED to TEA/OFF/COFFEE Switch TL2 - WHI to Power Cord (120V Models) or WHI to T erminal Block (120/208V Models) TL3 - WHI/ORN to ST ART Switch TL4 - WHI/GRN to Hot Coffee Solenoid TL5 - WHI/YEL to ST ART Switch FIG. 9 DIGIT AL TIMER WIRING P2037 SERVICE (cont.) DIGITAL BREW TIMER (HOT COFFEE - Lat ...

  • Bunn TWF - page 20

    Page 20 ...

  • Bunn TWF - page 21

    Page 21 Location: The timer is located inside the hood, on the right side. Test Procedure. NOTE: Do not remove or install wires while timer board is installed. Pressure applied to one side may cause damage to the board. 1. Disconnect the brewer from the power source and remove the front access panel. 2. Remove the two #8-32 screws securing circuit ...

  • Bunn TWF - page 22

    Page 22 TL1 - WHI/VIO to Iced T ea Solenoid and WHI/VIO to TEA/OFF/COFEE Switch TL2 - WHI to Power Cord (120V Models) or WHI to T erminal Block (120/208V Models) TL3 - ORN to ST AR T Switch TL4 - WHI/BLU to Iced T ea Solenoid TL5 - YEL to ST AR T Switch FIG. 13 DIGIT AL TIMER WIRING P2037 SERVICE (cont.) DIGITAL BREW TIMER (ICED TEA - Late Models)( ...

  • Bunn TWF - page 23

    Page 23 B U N N BUNN O F F OFF HI HI Location: The control thermostat is located inside hood on the right side to the left of the iced tea brew timer. Test Procedures: 1. Disconnect the brewer from the power sour ce. 2. With a voltmeter , check the voltage across the blue wire on the control thermostat and the white wire on the tank heater for 120 ...

  • Bunn TWF - page 24

    Page 24 SERVICE (cont.) DILUTION SOLENOID V AL VE FIG. 16 DILUTION SOLENOID V AL VE P2198.50 Location: Viewing the brewer from the rear the dilution so- lenoid is mounted on the right side of the solenoid mounting bracket which is secured to the trunk base. T est Procedure: 1. Disconnect the brewer from the power sour ce. 2. With a voltmeter , chec ...

  • Bunn TWF - page 25

    Page 25 SERVICE (cont.) LIMIT THERMOST A T FIG. 18 LIMIT THERMOST A T P2198.50 Location: The limit thermostat is located inside the hood on the tank lid. T est Procedure: 1. Disconnect the brewer from the power source and remove the black wire from the limit thermostat. 2. With a voltmeter , check the voltage across the black wire removed from the ...

  • Bunn TWF - page 26

    Page 26 FIG.21 TEA/OFF/COFFEE SWITCH TERMINALS P1367 SERVICE (cont.) TEA/OFF/COFFEE SWITCH FIG. 20 TEA/OFF/COFFEE SWITCH P1959.60 Location: The TEA/OFF/COFFEE switch is located in the front of the hood, above and to the left of the brew funnel. T est Procedure: 1. Disconnect the brewer from the power sour ce. 2 . Remove the black, white/violet and ...

  • Bunn TWF - page 27

    Page 27 SERVICE (cont.) ST ART SWITCH FIG. 22 ST ART SWITCH P1959.60 Location: The start switch is located in the front of the hood, above and to the right of the brew funnel. T est Procedure: 1. Disconnect the brewer from the power sour ce. 2. Remove the wires from all four terminals. 3. Check for continuity across the two terminals on the right s ...

  • Bunn TWF - page 28

    Page 28 ...

  • Bunn TWF - page 29

    Page 29 ...

  • Bunn TWF - page 30

    Page 30 SERVICE (cont.) HALF BA TCH SWITCH (Optional) FIG. 28 HALF BA TCH SWITCH P1959.60 Location: The HALF BA TCH switch is located in the front of the hood, above and to the far left of the brew funnel. T est Procedure: 1. Disconnect the brewer from the power sour ce. 2. With an ohmmeter , check for continuity between the two terminals of the sw ...

  • Bunn TWF - page 31

    Page 31 ...

  • Bunn TWF - page 32

    Page 32 10510 112000 10502.0003A 9/00 ©2000 BUNN-O-MA TIC CORPORA TION READY INDICATOR BLK BLU ...

Fabbricante Bunn Categoria Coffeemaker

I documenti che otteniamo dal fabbricante del dispositivoBunn TWF possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bunn
- manuali per l’uso TWF
- schede prodotto Bunn
- opuscoli
- o etichette energetiche Bunn TWF
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bunn TWF.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bunn TWF, manuali di manutenzione, brevi manuali o manuali utente Bunn TWF. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bunn TWF.

Manuali per l’uso simili

Manuale completo del dispositivo Bunn TWF, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bunn TWF dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bunn TWF.

Il manuale per l’uso completo Bunn, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bunn TWF - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bunn TWF, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bunn TWF che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bunn TWF - che ci dovrebbe aiutare nei primi passi durante l'uso Bunn TWF
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bunn TWF
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bunn TWF in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bunn TWF?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bunn TWF con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bunn TWF è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)