    Page 1 Ser vice & P ar ts Man ual AMERICA’S BEST AIR CONDITIONER 1998 QuietMaster ® J Series KS10J10 KS12J10 KS12J30A KM18J30A KM21J30 KL25J30 RA C-K (1/98) ...

  • Friedrich KS12J30A - page 2

    Page 2 T ABLE OF CONTENTS PA G E GENERAL F riedrich Room Model Number Code ............................................................................................... ........ 3 Application and Sizing ......................................................................................................... ..................... 4 Instructions f ...

  • Friedrich KS12J30A - page 3

    Page 3 FRIEDRICH R OOM MODEL NUMBER CODE K S 10 G 1 0 D 1st DIGIT - FUNCTION S = Straight Cool, V alue Ser ies C = Straight Cool, Budget Series Y = Heat Pump E = Electric Str ip K = Straight Cool, Challenger or QuietMaster Series W = Thru-The-W all, WallMaster Series 2nd DIGIT - TYPE C = Casement P = P owerMiser “P ortable” Q = QStar , KStar or ...

  • Friedrich KS12J30A - page 4

    Page 4 APPLICA TION AND SIZING In the application and sizing of room air conditioners f or cooling, it is most impor tant to giv e full consideration to all f actors which may contrib ute to the heat loss or gain of the space to be conditioned. It is theref ore necessar y to make a sur v e y of the space to be conditioned and calculate the load req ...

  • Friedrich KS12J30A - page 5

    Page 5 INSTR UCTIONS FOR USING COOLING LO AD ESTIMA TE FORM FOR ROOM AIR CONDITIONERS (AHAM PUB. NO . RA C-1) A. This cooling load estimate f or m is suitable f or estimating the cooling load f or comfort air conditioning installations which do not require specific conditions of inside temperature and humidity . B . The f or m is based on an outsid ...

  • Friedrich KS12J30A - page 6

    Page 6 COOLING LO AD ESTIMA TE FORM ...

  • Friedrich KS12J30A - page 7

    Page 7 SPECIFICA TIONS KS10J10 KS12J10 KS12J30A KM18J30A KM21J30 KL25J30A BTUH 12500 18000 21000 25000 10000 12000 12500 18000 20500 24700 E.E.R. 10.0 9.6 9.0 8.3 10.3 9.5 10.0 9.6 9.0 8.2 V olts 230 230 230 230 115 115 208 208 208 208 Amperes 5.8 8.3 10.5 13.5 9.1 10.8 6.2 9.1 11.3 15.0 T otal W atts 1250 1875 2335 3010 970 1265 1250 1875 2280 301 ...

  • Friedrich KS12J30A - page 8

    Page 8 COMPONENTS OPERA TION & TESTING W ARNING DISCONNECT ELECTRICAL PO WER T O UNIT BEFORE SER VICING OR TESTING COMPRESSORS Compressors are single phase, 15 or 230/208 v olt, de- pending on the model unit. All compressor motors are per manent split capacitor type using only a running ca- pacitor across the star t and r un ter minal. All comp ...

  • Friedrich KS12J30A - page 9

    Page 9 The ov erload is wired in ser ies with the common motor ter minal. The ov erload senses both major amperage and compressor temperature . High motor temperature or amperage heats the disc causing it to open and break the circuit to the common motor ter minal. Figure 3: External Overload Heat generated within the compressor shell is usually du ...

  • Friedrich KS12J30A - page 10

    Page 10 Figure 5: F an Motor 5. Apply “live” test cord probes on each of the re- maining wires from the speed s witch or system s witch to test intermediate speeds. CAP A CIT OR, R UN A run capacitor is wired across the auxiliar y and main winding of a single phase per manent split capacitor motor such as the compressor and f an motor . A singl ...

  • Friedrich KS12J30A - page 11

    Page 11 Figure 7: System Control P anel THERMOST A T (Figure 9) A cross ambient ther mostat is used on all standard chas- sis units. In addition to cycling the unit in a heating or cooling operation, the thermostat will ter minate the cool- ing cycle in the e vent ice f or ms on the ev aporator coil, in this case the ther mostat functions as a de-i ...

  • Friedrich KS12J30A - page 12

    Page 12 RESIST OR (Heat Anticipator) F ailure of the resistor will cause prolonged “off ” and “on” cycles of the unit. When replacing a resistor , be sure and use the e xact replacement. Resistor ratings are as f ollows: 115 V olt - 5,000 ohms 3 watt 230 V olt - 20,000 ohms 3 watt Figure 10 RESIST OR FIGURE 11 R OCKER SWITCH MONEYSA VER ® ...

  • Friedrich KS12J30A - page 13

    Page 13 a. Balance Scales - 1/2 oz. accuracy b . Charging Board - 1/2 oz. accuracy 9. High Pressure Gauge - (0 - 400 lbs.) 10. Low Pressure Gauge - (30 - 150 lbs .) 11. V acuum Gauge - (0 - 1000 microns) EQ UIPMENT MUST BE CAP ABLE OF: 1. Recovering CFCs as low as 5%. 2. Evacuation from both the high side and lo w side of the system simultaneously ...

  • Friedrich KS12J30A - page 14

    Page 14 R O T AR Y COMPRESSOR SPECIAL TROUBLESHOO TING AND SER VICE Basically , troubleshooting and servicing rotar y compres- sors is the same as on the reciprocating compressor with only a fe w exceptions. 1. Because of the spinning motion of the rotar y , the mounts are critical. If vibration is present, chec k the mounts carefully . 2. The elec ...

  • Friedrich KS12J30A - page 15

    Page 15 Troubleshooting Cooling PROBLEM POSSIBLE CA USE T O CORRECT Check for voltage at compressor. 1115 volt and 230 volt units will operate at 10% voltage variance. Set thermostat to coldest position. Test thermostat and replace if inoperative. Hard start compressor. Direct test compressor. If com- pressor starts, add starting components. Check ...

  • Friedrich KS12J30A - page 16

    Page 16 PROBLEM POSSIBLE CA USE T O CORRECT Replace fuse, reset breaker. If repeats, check fuse or breaker size. Check for shorts in unit wiring and compo- nents Plug in power cord Set switch correctly. Test for continuity in each switch position. Check wiring and connections. Reconnect per wiring diagram. Fuse blown or circuit tripped. Power cord ...

  • Friedrich KS12J30A - page 17

    Page 17 PROBLEM POSSIBLE CA USE T O CORRECT Compressor attempts to start, or runs for short periods only. Cycles on overload. Check operation of unit. Replace overload if system operation is satisfactory. Allow a minimum of two (2) minutes for pressures to equalize before attempting to restart. Instruct customer of waiting period. Check voltage wit ...

  • Friedrich KS12J30A - page 18

    Page 18 PROBLEM POSSIBLE CA USE T O CORRECT Thermostat short cycles. Thermostat differential too narrow. Plenum gasket not sealing, allowing discharge air to short cycle the thermostat. Restricted coil or dirty filter. Thermostat bulb touching thermostat bulb support bracket. Replace thermostat. Check gasket, reposition or replace. Clean and advise ...

  • Friedrich KS12J30A - page 19

    Page 19 ...

  • Friedrich KS12J30A - page 20

    Page 20 ...

  • Friedrich KS12J30A - page 21

    Page 21 ...

  • Friedrich KS12J30A - page 22

    Page 22 * Not Shown QUIETMASTER "KS" - "KM" SERIES P AR TS LIST REF . P AR T NO . DESCRIPTION APPLICA TION KKK K K SSS M M 111 1 2 022 8 1 JJJ J J 113 3 3 000 0 0 ELECTRICAL P AR TS AA 1 615-628-09 Compressor , T ecumseh, 115 V ., 60 Hz., 1 Ph., Model RK5510E .................................. 1 1 615-628-00 Compressor , T ecums ...

  • Friedrich KS12J30A - page 23

    Page 23 QUIETMASTER "KS" - "KM" SERIES P AR TS LIST REF . P AR T NO . DESCRIPTION APPLICA TION KKKK K REFRIGERA TION SYSTEM COMPONENTS (Cont.) SSS M M 1111 2 0228 1 JJJJ J 1133 3 0000 0 AA 13 618-027-00 Panel Assemb ly , Left Side .......................................................................................... ... 1 1 ...

  • Friedrich KS12J30A - page 24

    Page 24 QUIETMASTER "KS" - "KM" SERIES P AR TS LIST REF . P AR T NO . DESCRIPTION APPLICA TION KK KKK SS S M M 11 112 02 281 JJ J JJ 11 333 00 000 AA CHASSIS P AR TS (Cont.) 34 914-004-00 Bolt, Compressor Mounting ............................................................................................... 3 3 3 3 3 35 618-102 ...

  • Friedrich KS12J30A - page 25

    Page 25 ...

  • Friedrich KS12J30A - page 26

    Page 26 ...

  • Friedrich KS12J30A - page 27

    Page 27 QUIETMASTER "KL" SERIES P AR TS LIST REF . P AR T NO . DESCRIPTION APPLICA TION K L 2 5 J 3 0 ELECTRICAL P AR TS A 1 615-935-47 Compressor , T ecumseh, 230/208 V ., 60 Hz., 1 Ph., Model A WR5524EXN ........................................ 1 2 610-714-85 Motor , F an ................................................................. ...

  • Friedrich KS12J30A - page 28

    Page 28 QUIETMASTER "KL" SERIES P ARTS LIST REF . P AR T NO . DESCRIPTION APPLICA TION K L 2 5 J 3 0 CHASSIS P AR TS (Cont.) A 23 606-106-02 Blower Wheel ........................................................................................................................... 1 24 618-066-00 Inner W all .................................. ...

  • Friedrich KS12J30A - page 29

    Page 29 Use F actor y Cer tified P ar ts . . . Printed in U.S .A. Friedrich Air Conditioning Co. 4200 Nor th P an Am Expressw ay • P .O . Bo x 1540 San Antonio , T e xas 78295-1540 • U .S.A. Phone: (210) 357-4400 F ax: (210) 357-4480 RA C-K (1/98) ...

Fabbricante Friedrich Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoFriedrich KS12J30A possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Friedrich
- manuali per l’uso KS12J30A
- schede prodotto Friedrich
- opuscoli
- o etichette energetiche Friedrich KS12J30A
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Friedrich KS12J30A.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Friedrich KS12J30A, manuali di manutenzione, brevi manuali o manuali utente Friedrich KS12J30A. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Friedrich KS12J30A.

Manuali per l’uso simili

Manuale completo del dispositivo Friedrich KS12J30A, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Friedrich KS12J30A dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Friedrich KS12J30A.

Il manuale per l’uso completo Friedrich, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Friedrich KS12J30A - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Friedrich KS12J30A, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Friedrich KS12J30A che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Friedrich KS12J30A - che ci dovrebbe aiutare nei primi passi durante l'uso Friedrich KS12J30A
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Friedrich KS12J30A
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Friedrich KS12J30A in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Friedrich KS12J30A?

Utilizza il modulo sottostante

Se non hai risolto il problema con Friedrich KS12J30A con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Friedrich KS12J30A è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)