    A gilen t E361x A 60W B ENCH SERIES DC POWER SUPPLIES OPERA TING A N D SER VICE M A NUA L FOR M ODELS: A gilent E361 4A , Serials KR835 03035 and above A gilent E361 5A , Serials KR835 06197 and above A gilent E361 6A , Serials KR835 02651 and above A gilent E361 7A , Serials KR835 02522 and above For instruments with higher Serial Numbers than abo ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 2

    1-2 SA FETY SUMMARY The following gener al safety precaut i ons must be observed during all phas es of operation, service, and repair of t his instrumen t. Failure to c omply with these precautions or with s pecific warnings elsewhere in this manual violates sa fety standards of design , manufactur e, and intended use of the instrument . Agilent T ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 3

    1-3 T able of Contents SAFETY SUMMARY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2 GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 -4 INTRODUCTION . . . . . . . . . . . . . . . . ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 4

    1-4 GENERA L INFORMA TION INTRODUC TION This manual describes all models in the Agilent E 361xA 6 0W Bench Power Supply family and unless stated other wise, the information in this manual applies to all models. SA FET Y REQU IREM ENTS This product is a Safety Class I instrument, which means that it is provided with a protective earth ground termina ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 5

    1-5 b e g rounded or the power suppl y can be operated float- in g at up to a maximum of 240 V olts o f f g round. T otal out- put voltage to g round must not exceed 240 Vdc. LINE FUSE Line V oltage Fuse Agilent Part No. 100/ 1 15 V ac 2.0 A T 2 1 10-0702 230 V ac 1.0 A T 2 1 10-0457 SPECIFIC A TIONS Detailed specifications for the power suppl y ar ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 6

    1-6 T able 1. Specifications and Operati n g Characteristics (Cont’d) *REMOTE PROGRAMMING SPEED Maximum time required for output volta g e to chan g e from initial value to within a tolerance band (0.1%) of the new l y pro g rammed value followin g the onset of a step chan g e in the pro g rammin g input volta g e. Full load No load Up: E3614A: 3 ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 7

    1-7 e . Replace the cover and mark the suppl y clearl y with a ta g or label indicatin g the correct line volta g e and fuse that is in use. Fig ure 2. Line V olta g e Selector (set for 1 15 V ac) Power Cord T o protect operatin g personnel, the instrument should be g rounded. This instrument is equipped with a three conductor power cord. The third ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 8

    1-8 that the current limit value can be set from zero to maximum rated value. OPERA TING MODES The settin g of the rear panel switch determines the operatin g modes of the power suppl y . The local operatin g mode is set so the power suppl y senses the output volta g e directl y at the output terminals (local sensin g ) for operation usin g the fro ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 9

    1-9 REMOTE OPERA TING MODES Remote operatin g modes discussed below are remote volta g e sensin g and remote volta g e pro g rammin g . Y ou can set up the unit for remote operatin g modes b y chan g in g the settin g s of the rear panel switch and connectin g the leads from the rear panel termi- nals to the load or the external volta g e. Solid co ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 10

    1-10 pl y above 100% rated output. Limit y our pro g rammin g volta g e to 10 Vdc. Remote Pro g rammin g Connections. Remote pro g rammin g requires chan g in g settin g s of the switch and connectin g external volta g es to + and - terminals of "CV" or "CC" on the rear panel. An y noise picked up on the pro g rammin g leads wil ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 11

    1-11 Settin g V olta g e and Current. T urn the slave unit's CURRENT control full y clockwise. Adjust the master unit's controls to set the desired output volta g e and current. The master suppl y operates in a completel y normal fashion and ma y be set up for either con- stant volta g e or constant current operation as required. V erif y ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 12

    1-12 AUTO-SERIES OPERA TION Auto-series operation permits equal or proportional volta g e sharin g , and allows control of output volta g e from one master unit. The volta g e of the slaves is determined b y the settin g of the front panel VOL T AGE control on the master and volta g e divider resistor . The master unit must be the most positive sup ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 13

    1-13 Remote Sensin g . T o remote sense with auto-series operation, set SENSE switch of the master unit and set SENSE switch of the slave unit to remote. Remote Analo g V olta g e Pro g rammin g . T o remote analo g pro- g ram with auto-series operation, connect pro g ram (external) volt- a g es to the "CV" or "CC"" termina ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 14

    1-14 LOAD CONSIDERA TIONS This section provides information on operatin g y our suppl y with various t y pes of loads connected to its output. PULSE LOADING The power suppl y will automaticall y cross over from constant- volta g e to constant current operation in response to an increase (over the preset limit) in the output current. Althou g h the ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 15

    A-1 SERVICE INFORMA TION Figure A-1. Block D iagram PRINCIPLES OF OPE R A TION (Block Diagram Overview ) Throughout t his discussion, refer t o both the block d i agram of Figure A-1 and t he schemat ic diagrams at the rear of the manual. The input ac line voltage is first applied to the prereg- ulator w hich operate s in c onj unction with t he SC ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 16

    A-2 series pass transistors. Whenever the output volta g e is below the slopin g V1 line, the control circuit inhibits four SCRs and the input capacitors char g e to a volta g e determined b y N1. Fi g ure A-2 indicates the windin g s that are connected as a result of the other volta g e decisions. Fi g ure A-2. Output Power Plot The series re g ul ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 17

    A-3 a . Perform turn-on checkout procedure g iven in pa g e 1-7. b . Perform the CV and CC Load Re g ulation perfor- mance tests g iven in the followin g para g raphs respectivel y . PERFORMANCE TESTS The followin g para g raphs provide test procedures for verif y- ing the power suppl y 's compliance with the specifications of T able 1. Please ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 18

    A-4 CONST ANT VOL T AGE (CV) TESTS CV Setup. For all CV tests set the output current at full rated output to assure CV operation. The onset of constant current can cause a drop in output volta g e, increased ripple, and other performance chan g es not properl y ascribed to the con- stant volta g e operation of the suppl y . Load Regulation (Load Ef ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 19

    A-5 Fi g ure A-5. Load T ransient Response Time W aveform P ARD(Ripple and Noise) Definition: P ARD is the Periodic and Random Deviation of the dc output volta g e from its avera g e value, over a specified bandwidth and with all other parameters maintained constant. Constant volta g e P ARD is measured in the root-mean- square(rms) or peak-to-peak ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 20

    A-6 a. Connect the test equipment as shown in Fi g ure A-7. b. T urn the suppl y 's power on and turn CURRENT con- trol full y clockwise. c. T urn up output volta g e to the full rated value. Check that the suppl y 's CV indicator remains li g hted. Reduce VOL T AGE control if not li g hted. d. Set the oscilloscope to AC mode and bandwidt ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 21

    A-7 e. Record output volta g e across Rs and convert it to current b y dividin g this volta g e b y Rs. f. Adjust autotransformer to the hi g h line volta g e (127 V ac for nominal 1 15 V ac, 1 10 V ac for nominal 100 V ac, and 253 V ac for nominal 230 V ac). g . When the readin g settles, record the volta g e across Rs a g ain and convert it curre ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 22

    A-8 Ammeter and CC Set Calibration T o calibrate ammeter and CC set, proceed as follows: a. Connect test setup on Fi g ure A-9. b. T urn VOL T AGE and CURRENT control full y clock- wise. c. T urn on the suppl y and to calibrate ammeter adjust R5 on the displa y board until front panel AMPS dis- pla y reads exactl y DVM value divided b y Rs. d. T o ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 23

    A-9 After the trouble has been isolated to one of the feedback loops, troubleshootin g can proceed as described in T ables A- 4, A-5, or A-6. Series Re g ulatin g Feedback Loop. When troubleshootin g the series re g ulatin g loop, it is useful to open the loop since measurements made an y where within a closed loop ma y appear abnormal. With a loop ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 24

    A-10 SYMPTOM CHECKS AND PROBABLE CAUSES Poor Load Re g ulation (Constant V olta g e) a. Refer to "Measurements T echniques" para g raph. b. Check +10 V reference volta g e. c. Ensure that the suppl y is not g oin g into current limit. Poor Load Re g ulation (Constant Current) a. Check +10 V reference volta g e. b. CR1, CR19, CR20, C2, C31 ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 25

    A-11 STEP ACTION RESPONSE PROBABLE CAUSE 4 Check volta g e from pin 13 to pin 12 of U9. a. Measured volta g e is positive. b. Measured volta g e is ne g ative. a. Check U9A is defective. b. Check U10 and U9D is defective. Check R85 is open. 5 Check volta g e from pin 6 to pin 5 of U9. a. Measured volta g e is positive. b. Measured volta g e is ne g ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 26

    A-12 REPL A CEA B LE P A R TS IN TROD UCTI ON This section contains informat ion for ordering replacement parts. T able A-10 lists p arts by reference designators and pro- vides the following inf ormation: a. Reference designat ors. Refer to T able A-8. b. Agilent T echnologies Part Number . c. T otal quantity used in that assembly. d. Description. ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 27

    Table A -10. Replaceable P arts List Reference Designator Number Q'ty Description Model Mfr. P/N Mfr. Code E3614A 1 60W BENCH POWER SUPPLY - E3614A MODEL E3615A 1 60W BENCH POWER SUPPLY - E3615A MODEL E3616A 1 60W BENCH POWER SUPPLY - E3616A MODEL E3617A 1 60W BENCH POWER SUPPLY - E3617A MODEL E3614-60005 1 MAIN BODY ASSY 14 28480 E3615-60005 ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 28

    Table A -10. Replaceable P arts List (Co nt'd) Reference Designator Agilent Part Number Q'ty Description Model Mfr. P/N Mfr. Code C18,21,24,27 0160-7077 4 CAP-FXD .1UF +-10% 630V POLYE-FL 14,15 28480 C19,22 0160-4822 2 CAP-FXD 1000PF +-5% 100V CER COG 14,15 28480 C20,23 0180-3970 2 CAP-FXD 1UF +-20% 50V AL-ELECTLT 14,15 28480 C28 0160-622 ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 29

    Table A -10. Replaceable P arts List (Co nt'd) Reference Designator Agilent Part Number Q'ty Description Model Mfr. P/N Mfr. Code R24,26,27,37,38, 64,88,117,120 0757-0442 9 RESISTOR 10K +-1% .125W TF TC=0+-100 ALL 28480 R25,30,33 0698-8824 3 RESISTOR 562K +-1% .125W TF TC=0+-100 ALL 28480 R28,111 0698-3228 2 RESISTOR 49.9K +-1% .125W TF T ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 30

    R62 0698-4514 1 RESISTOR 105K +-1% .125W TF TC=0+-100 15 28480 R62 0757-0481 1 RESISTOR 475K +-1% .125W TF TC=0+-100 16 28480 Table A -10. Replaceable P arts List (Co nt'd) Reference Designator Agilent Part Number Q'ty Description Model Mfr. P/N Mfr. Code R62 0698-8826 1 RESISTOR 825K +-1% .125W TF TC=0+-100 17 28480 R63 0698-8827 1 RESIS ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 31

    R109 0698-3153 1 RESISTOR 3.83K +-1% .125W TF TC=0+-100 ALL 28480 R115 0757-0462 1 RESISTOR 75K +-1% .125W TF TC=0+-100 14 28480 Table A -10. Replaceable P arts List (Co nt'd) Reference Designator Agilent Part Number Q'ty Description Model Mfr. P/N Mfr. Code R115 0757-0463 1 RESISTOR 82.5K +-1% .125W TF TC=0+-100 15 28480 R115 0757-0462 1 ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 32

    Table A -10. Replaceable P arts List (Co nt'd) Reference Designator Agilent Part Number Q'ty Description Model Mfr. P/N Mfr. Code CR21,22,23,24,25, 26,27,28,29,30 1901-0033 10 DIODE-GEN PRP 180V 200MA DO-35 ALL 1N645 27014 VR1,2,3 1902-0579 3 DIODE-ZNR 5.1V 5% PD=1W IR=10UA ALL 1N4733APL 04713 RT1,2 0837-0261 2 DIODE-VARISTOR ALL V275LA20 ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 33

    Table A-11. Component Val ue Component Model E3614A E3615A E3616A E3617A C2 1000UF 25V +-20% AL-ELECTLT 470UF 50V +-20% AL-ELECTLT 330UF 50V +-20% AL-ELECTLT 220UF 100V +-20% AL-ELECTLT C7,8 39000UF 25V +-20% AL-ELECTLT 12000UF 63V +-20% AL-ELECTLT 5600UF 100V +-20% AL-ELECTLT 2700UF 160V +-20% AL-ELECTLT C11,16,17,25,26 0.01UF 100V +-10% CER X7R 0 ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 34

    Manual Supple ment Suppleme nt Agilent Part Numbe r : 5959-53 36, Edition 4 Supple ment Print Date : 14 A pril, 2000 This supplement update s th e following docume nt: Agilen t E 361XA 60W Serie s Lab Bench DC Power Supplie s Manual Agile nt Part Nu mber : 5959 -5310 What is a manual suppleme nt? A manual suppleme nt keeps your manual up-to-date . ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 35

    1-10-1 Voltage and Current Programming of the E3614A/15A/16A/ 17A with a Voltage and Current Source Remote analog voltage programming permits control of the regulated output voltage or current by means of a remotely varied voltage or current. The stability of the programming voltages directly affects the stability of the output. The voltage control ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 36

    1-10-2 Programming V oltage Common to the Minus Output Figure 2 Set the CV switch down on the rear panel, and all others up. V in = 1/A x V out V out = A x V in Where V out is the power supply output voltage. V in is the programming voltage. A is the gain factor and the values of each model are as below . Alternative Voltage Programming Using Resis ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 37

    1-10-3 Programming V oltage Common to the Minus Output Figure 4 The output will always be the same or less than the programming voltage. The M/S2 switch must be in the down position. For best results, place a 0.1 µ F capacitor in parallel with R2. V in = (R1  R2) / R2 x V out V out = R2 /  R1+R2) x V in Where V out is the power supply output ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 38

    1-10-4 Constant Current Mode The E3614A/15A/16A/17A may be programmed for constant current with an analog voltage or current. Constant current with analog voltage programming can only be achieved with a voltage source that is common with the positive output terminal. Constant Current with V oltage Programming Figure 5 Set the CC switch down the rea ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 39

    1-10-5 Figure 6 Set the CC switch down, and all others up. I in = 1/A x I out I out = A x V in Where I out is the power supply output current in amps. I in is the programming current in µ amps. A is the gain. Programming currents can be increased by adding a resistor across the CC+ and CC-. A 10 volts drop across R1 represents full scale current o ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 40

    1-10-6 Voltage and Current Programming of the E3614A/15A/16A/17A with Resistors Remote programming with resistors permits control of the regulated output or current by means of a remotely varied resistor . The sum of the resistance of external programming resistors (R1 + R2) should be more than 40 kohm. T o have mor e pr ecise output voltage , use ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 41

    1-10-7 Remote Resistor Programming, Constant Current Figure 8 Set the CC switch down on the rear panel, and all others up. I out = A x [V REF x {R/(R + R2 + 100)}] Where I out is the power supply output current. A is the gain factor and the values of each model are as below . V REF is between 10.1 1 V and 11.40 V . R = (92800 x R1)/(92800 + R1) R1 ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 42

    CERTIFICATION Agilent T echno l ogies certifies that this product met its pub li shed specificat i ons at t i me of shipmen t fro m t he fa ctory . Agilent T ech nologies furthe r certifies that its calibrat ion meas ureme nts are trac eable to the United St ates Na tional Instit ute of Stan- dards and T echnology (fo rmerly N ational Bureau of S t ...

  • Agilent Technologies Agilent E3617A Serials KR83502522 - page 43

    DECLA RA TION OF CONFORMITY accordi ng to ISO/IEC Guide 22 an d EN 45014 Manufactu rer’s Name: Agilent Tec hnologies, Inc. Manufactu rer’s A ddress : 345-15, Ka san-dong, Kumch on-ku, Seoul 15 3-023 Korea declares, that the products Product Na me: DC Power Supply Model Numbers : E3614A, E3615 A, E3614A, E36 15A, and E3617A Product Opt ions: All ...

Fabbricante Agilent Technologies Categoria Video Gaming Accessories

I documenti che otteniamo dal fabbricante del dispositivoAgilent Technologies Agilent E3617A Serials KR83502522 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Agilent Technologies
- manuali per l’uso Agilent E3617A Serials KR83502522
- schede prodotto Agilent Technologies
- opuscoli
- o etichette energetiche Agilent Technologies Agilent E3617A Serials KR83502522
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Agilent Technologies Agilent E3617A Serials KR83502522.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Agilent Technologies Agilent E3617A Serials KR83502522, manuali di manutenzione, brevi manuali o manuali utente Agilent Technologies Agilent E3617A Serials KR83502522. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Agilent Technologies Agilent E3617A Serials KR83502522.

Manuale completo del dispositivo Agilent Technologies Agilent E3617A Serials KR83502522, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Agilent Technologies Agilent E3617A Serials KR83502522 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Agilent Technologies Agilent E3617A Serials KR83502522.

Il manuale per l’uso completo Agilent Technologies, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Agilent Technologies Agilent E3617A Serials KR83502522 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Agilent Technologies Agilent E3617A Serials KR83502522, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Agilent Technologies Agilent E3617A Serials KR83502522 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Agilent Technologies Agilent E3617A Serials KR83502522 - che ci dovrebbe aiutare nei primi passi durante l'uso Agilent Technologies Agilent E3617A Serials KR83502522
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Agilent Technologies Agilent E3617A Serials KR83502522
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Agilent Technologies Agilent E3617A Serials KR83502522 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Agilent Technologies Agilent E3617A Serials KR83502522?

Utilizza il modulo sottostante

Se non hai risolto il problema con Agilent Technologies Agilent E3617A Serials KR83502522 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Agilent Technologies Agilent E3617A Serials KR83502522 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)