    PO WER SY STEMS, INC. ® Owner’ s Manual GTS “HS” T ype A utomatic T ransfer Switc h Models: 004635-3 (200 Amp, 250 V olts) and 004678-2 (100 Amp, 250V olts) This manual should remain with the unit. ...

  • Generac 004635-3 - page 2

    Generac ® Pow er Systems, Inc. Generac cannot possibly anticipate every possible circumstance that might involve a hazard. The warn- ings in this manual, and on tags and decals affixed to the unit are, therefore, not all-inclusive. If using a procedure, work method or operating tech- nique Generac does not specifically recommend, ensure that it is ...

  • Generac 004635-3 - page 3

    T able of Contents Generac ® Pow er Systems, Inc. 1 Safety Rules..........................................Inside Front Cover Section 1 — General Information ..................................2 1.1 Introduction ............................................................2 1.2 Equipment Description ............................................2 1.3 ...

  • Generac 004635-3 - page 4

    2 Generac ® Pow er Systems, Inc. Section 1 — General Information Generac GT S “HS” T ype T ransfer Switch 1.1 I NTRODUCTION This manual has been prepared especially for the purpose of familiarizing personnel with the design, application, installation, operation and servicing of the applicable equipment. Read the manual carefully and comply w ...

  • Generac 004635-3 - page 5

    Generac ® Pow er Systems, Inc. 3 2.1 I NTRODUCTION T O I NST ALLA TION This equipment has been wired and tested at the fac- tory . Installing the switch includes the following pro- cedures: • Mounting the enclosure. • Connecting power source and load leads. • Connecting the generator start circuit. • Connecting any auxiliary contact (if ne ...

  • Generac 004635-3 - page 6

    4 Generac ® Pow er Systems, Inc. Section 3 — Operation Generac GT S “HS” T ype T ransfer Switch Connect power source load conductors to clearly marked transfer mechanism terminal lugs as follows 1. Connect UTILITY (NORMAL) power source cables to switch terminals N1, N2. 2. Connect EMERGENCY (ST ANDBY) source power cables to transfer switch t ...

  • Generac 004635-3 - page 7

    Generac ® Pow er Systems, Inc. 5 3.2.2 CL OSE T O EM ERGENCY SOURCE SI DE Before proceeding, verify the position of the switch by observing the position of the manual operation han- dle in Figure 3.1. If the handle is DOWN, the contacts are closed in the EMERGENCY (ST ANDBY) position. No further action is required. If the handle is UP, pro- ceed w ...

  • Generac 004635-3 - page 8

    6 Generac ® Pow er Systems, Inc. PROCEED WITH CAUTION. GENERA TOR OUT- PUT VOL T AGE IS NOW BEING DELIVERED TO TRANSFER SWITCH TERMINALS. CONT ACT WITH LIVE TERMINALS RESUL TS IN EXTREMEL Y DANGEROUS AND POSSIBL Y FA T AL ELECTRI- CAL SHOCK. 7. W ith an accurate AC voltmeter and frequency meter , check the no -load, voltage and frequency . Single ...

  • Generac 004635-3 - page 9

    Section 4 — Notes Generac GT S “HS” T ype T ransfer Switch Generac ® Pow er Systems, Inc. 7 ...

  • Generac 004635-3 - page 10

    8 Generac ® Pow er Systems, Inc. Section 4 — Notes Generac GT S “HS” T ype T ransfer Switch ...

  • Generac 004635-3 - page 11

    Generac ® Pow er Systems, Inc. 9 Section 4 — Notes Generac GT S “HS” T ype T ransfer Switch ...

  • Generac 004635-3 - page 12

    Section 5 — Installation Diagram Generac GT S “HS” T ype T ransfer Switch Drawing No. 0E7 08 1 3 77mm [ 14.84" ] 5 08.5mm [ 20.02" ] KN OC K OU T SU ITABLE F OR 1 " , 1-1/2" AND 2" CONDUIT SIZE 3 PLA C E S 1 79.5mm [ 7.07" ] 4 20mm [ 16.54" ] 4 5mm [ 1.77" ] 4 1.5mm [ 1.63" ] 2 94mm [ 11.57" ] ...

  • Generac 004635-3 - page 13

    Generac ® Pow er Systems, Inc. 11 - O PEN S WIT C H T O TE S T - 2A @ 2 50 Vac MIN . SWITCH TYPE , SPS T ELECTRICAL RATINGS , U TILITY 1 U TILITY 2 1 94 C B 1 NE U TRA L CO NNE C TI ON N1 N2 T1 T2 E1 E2 NE U TRA L L UG TRAN S FE R S WIT CH U TILIT Y SU PPL Y L O A D CUS T O ME R 19 4 23 U TILITY 2 U TILITY 1 A C G ENERAT OR CO NTR O L PANE L N O T ...

  • Generac 004635-3 - page 14

    N O N C N C N O XA1 COM C1 VR1 COM XB1 C2 VR2 ALL CO NTA C T S S H O WN WIT H TRAN S FER S WIT C H IN U TILIT Y P OS ITI O N . N O TE : LIMIT SWITCHES , ACTUATO R TERMINAL STRIP ( CUSTOMER CONNECTION ) NB - NEUTRAL BLOC K VARI S T OR FUSE , 5 A XA1 , XB 1 VR1 , VR 2 F1 , 2 , 3 & 4 NB TB TR A 1 94 2 3 1 94 TB7 TB 6 2 3 A TR B B A B E1 12 6 1 N2A ...

  • Generac 004635-3 - page 15

    Generac ® Pow er Systems, Inc. 13 47 8 22- T 19 4 7 TB U TILITY 1 U TILITY 2 LO AD 1 3 ( OPTIONAL ) NEUTRAL * LO AD 2 2 3 4 5 6 CUS T O MER CO NTR OL CO NNE C TI O N S Z Y T2A 1 94 12 6 2 05 2 3 N2A N1A N2A E2 TR N1A N1A 1 94 B 9 6 3 1 N2A 2 3 B N1A N2A N1A A N2 N1 T1 F2 F1 F 3 T2 F4 2 3 T1A 1 94 T2A E2 2 05 E2 B T1A E1 E2 N2A N2A N1A N2A N1A N2A ...

  • Generac 004635-3 - page 16

    14 Generac ® Pow er Systems, Inc. 25 3 8 4 9 6 7 20 19 15 23 2 26 13 21 16 11 10 36 24 3 7 3 1 22 14 13 18 3 2 35 3 4 33 28 29 12 17 3 5 30 2 1 4 30A, 30A, 0735 0735 30A,600V 30A, 600V 073591 - T 073591T ( GROUND LUG ASSEMBLY ) DETAIL A - A E N C L OSU RE N OTE: TOR Q UE ITEM #3 TO 24-30 IN.LBS DETAIL B - B ( POWER TERMINAL LUG ASSEMBLY ) B B B CS ...

  • Generac 004635-3 - page 17

    Generac ® Pow er Systems, Inc. 15 ITEM P ART NO . QTY . DESCRIPTION 1 0C2237 1 TR SW -HSB 100A 2P 250V 2 077033 6 LUG SLDLSS 1/0-#14X9/16 AL/CU 3 036932 6 SCREW PPHM #10-32 X 1/4 4 022152 6 W ASHER LOCK #10 5 066849 4 SCREW HHTT M5-0.8 X 16 BP 6 045771 1 NUT HEX M8-1.25 G8 YEL CHR 7 062684 1 LUG SLDLSS 2/0-#12 X 11/32 CU 8 0C3168 1 W ASHER LOCK SP ...

  • Generac 004635-3 - page 18

    23 3 1 22 15 19 8 9 6 C 10 11 29 7 21 16 13 42 41 30 A LO AD 2 LO AD 1 UTILITY 2 UTILITY 1 194 23 N E U TRAL A A 20 14 13 18 26 27 A 40 A 5 33 17 12 24 1 2 38 3 4 25 36 35 4 3 4 7 8 22-T 05 7 3 2 9 - S E N C L OSU RE ( GROUND LUG ASSEMBLY ) DETAIL A - A A 3 T O 72 ± 1 IN-LB S N OTE: TOR Q UE ITEM CS3-8X16T C 8X16 0 A 95 17 WS34X14S S Y S TEM V O L ...

  • Generac 004635-3 - page 19

    Generac ® Pow er Systems, Inc. 17 Section 7 — Exploded Views and P arts List Generac GT S “HS” T ype T ransfer Switch 200A T ransfer Switch Assembly – Drawing No. 0E57 82$-E ITEM P ART NO . QTY . DESCRIPTION 1 0D9618 1 TR SW -HSB 200A 2P 250V 2 0E3375 6 LUG SLDLSS 250-#6 AL/CU 3 0E6058 6 SCREW SHC 1/4-20X3/8 4 022097 6 W ASHER LOCK M6-1/4 ...

  • Generac 004635-3 - page 20

    Part No. 0E6347 Revision D (02/05/04) Printed in U.S.A. Section 8 — W arranty Generac GT S “HS” T ype T ransfer Switch GEN ERAC PO WER SY S TEMS S T AN D AR D T WO- YEAR LI M ITED W ARR ANT Y FOR GEN ERAC TRANSF ER SWIT CH SY S TEMS NOTE: ALL UNITS MUST HA VE A ST ART -UP INSPECTION PERFORMED BY AN A UTHORIZED GENERAC DEALER. F or a period of ...

Fabbricante Generac Categoria Switch

I documenti che otteniamo dal fabbricante del dispositivoGenerac 004635-3 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Generac
- manuali per l’uso 004635-3
- schede prodotto Generac
- opuscoli
- o etichette energetiche Generac 004635-3
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Generac 004635-3.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Generac 004635-3, manuali di manutenzione, brevi manuali o manuali utente Generac 004635-3. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Generac 004635-3.

Manuali per l’uso simili

Manuale completo del dispositivo Generac 004635-3, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Generac 004635-3 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Generac 004635-3.

Il manuale per l’uso completo Generac, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Generac 004635-3 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Generac 004635-3, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Generac 004635-3 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Generac 004635-3 - che ci dovrebbe aiutare nei primi passi durante l'uso Generac 004635-3
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Generac 004635-3
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Generac 004635-3 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Generac 004635-3?

Utilizza il modulo sottostante

Se non hai risolto il problema con Generac 004635-3 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Generac 004635-3 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)