Empire Comfort Systems SR-30 - page 1
Page 1 INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL UNVENTED ROOM HEA TER MODELS SR-6-3 SR-10-3 SR-18-3 SR-30-3 SR-30 SHOWN This appliance may be installed in an aftermarket, permanently located, manufactured (mobile) home, where not pr ohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. T ...
-
Empire Comfort Systems SR-30 - page 2
16942-5-0907 Page 2 Important Safety Information ............................................................................... 3 Safety Information for Users of LP Gas ............................................................... 4 Introduction ..................................................................................................... ...
-
Empire Comfort Systems SR-30 - page 3
16942-5-0907 Page 3 • An unvented room heater having an input rating of more than 6,000 Btu per hour shall not be installed in a bathroom. • An unvented room heater having an input rating of more than 10,00 0 Btu pe r ho ur sh all no t be ins talle d in a be dro om or bathr oom. • Due to high temperatures, the appliance should be located out ...
-
Empire Comfort Systems SR-30 - page 4
16942-5-0907 Page 4 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor . Sometimes other odors in the area ...
-
Empire Comfort Systems SR-30 - page 5
16942-5-0907 Page 5 Instructions to Installer 1. Installer must leave instruction manual with owner after installation. 2. Installer must have owner fill out and mail warranty card supplied with unvented room heater . 3. Installer should show owner how to start and operate unvented room heater . Always consult your local Building Department regard ...
-
Empire Comfort Systems SR-30 - page 6
16942-5-0907 Page 6 W ater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour . Unvented room heaters must be used as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplemental h ...
-
Empire Comfort Systems SR-30 - page 7
16942-5-0907 Page 7 The gas line can be routed either through the floor or wall. The gas line opening should be made at this time. Location of the opening will be determined by the position of floor joists and the valve and union used for servicing. Gas Supply Check all local codes for requirements, especially for the size and type of gas supply ...
-
Empire Comfort Systems SR-30 - page 8
16942-5-0907 Page 8 Figure 3 (SR-6) When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 6 inches (152mm). Right side 6 inches 152mm). Do not install in alcove or closet. Rear wall 0 (0mm) inches. Ceiling 24 inches (610mm). Minimum vertical clearance from a projection abov ...
-
Empire Comfort Systems SR-30 - page 9
16942-5-0907 Page 9 Figure 5 (SR-10) CEILING WINDOW SILL OR SHELF 24” MIN (610mm) 14” MIN (356mm) 12” MAX (305mm) 0” (0mm) CLEARANCE TO REAR W ALL SIDE VIEW 2” MIN (51mm) FLOOR Figure 6 (SR-10) FLOOR CEILING SIDE W ALL 24” MIN (610mm) 14” MIN (356mm) 6” MIN (152mm) 6” MIN (152mm) 2” MIN (51mm) When facing the front of the applia ...
-
Empire Comfort Systems SR-30 - page 10
16942-5-0907 Page 10 When facing the front of the appliance the following minimum clearances to combustible construction must be maintained. Left side 8 inches (203mm). Right side 8 inches (203mm). Do not install in alcove or closet. Rear wall 0 inches (0mm). Ceiling 36 inches (914mm). Minimum vertical clearance from a projection above the applianc ...
-
Empire Comfort Systems SR-30 - page 11
16942-5-0907 Page 1 1 On Solid W all 1. After locating mounting holes, attach (4) #10 x 1" (25mm) screws provided into the wall. Do not completely tighten screwheads to the wall, leave a 1/8" (3mm) gap between screwheads and wall. 2. Mount heater onto the (4) screwheads and complete tightening screwheads into the wall. Attention! Use the ...
-
Empire Comfort Systems SR-30 - page 12
16942-5-0907 Page 12 1. Align clearance holes on floor stand with screw holes on bottom of heater , as shown in Figure 14. 2. Attach floor stand to heater with (4) screws provided with floor stand. 3. Connect the gas line. *Floor stand can not be used in a bathroom or bedroom installation. SR-6 must be wall mounted in a bathroom or bedroom insta ...
-
Empire Comfort Systems SR-30 - page 13
16942-5-0907 Page 13 FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result caus- ing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly . B. BEFORE LIGHTING ...
-
Empire Comfort Systems SR-30 - page 14
16942-5-0907 Page 14 SR-6 Main Burner Flame (Figur e 15) The main burner flame will have a red-orange glow over the sur- face of the ceramic plaque. The red-orange glow on the surface of the ceramic plaque will have a pattern in the shape of a number 1. The perimeter of the ceramic plaque [approximately the out- side 1/4"(6mm)] will not glow ...
-
Empire Comfort Systems SR-30 - page 15
16942-5-0907 Page 15 The correct flame will be blue and will extend beyond the thermocouple. The flame will surround the thermocouple just below the tip. A slight yellow flame may occur where the pilot flame and main burner flame meet. Figure 17 Oxygen Depletion Sensor Pilot (Figur e 16) When the pilot has a lar ge yellow tip flame, clean the ...
-
Empire Comfort Systems SR-30 - page 16
16942-5-0907 Page 16 1. Spark electrode does not produce spark. a. Spark electrode broken - replace. b. Ignitor wire may not be attached to spark electrode - attach. c. Ignitor wire damaged - replace. d. Piezo ignitor defective - replace. 2. Spark electrode produces spark but pilot does not light. a. No gas to heater - turn on gas. b. PILOT positio ...
-
Empire Comfort Systems SR-30 - page 17
16942-5-0907 Page 17 USE ONL Y MANUF ACTURER'S REPLACEMENT P AR TS. USE OF ANY OTHER P AR TS COULD CAUSE INJUR Y OR DEA TH. Parts can be ordered only through your service person or dealer . For best results, the service person or dealer should order parts through the distributor . Parts can be shipped directly to the service person/dealer . Al ...
-
Empire Comfort Systems SR-30 - page 18
16942-5-0907 Page 18 USE ONL Y MANUF ACTURER’S REPLACEMENT P AR TS. USE OF ANY OTHER P AR TS COULD CAUSE INJUR Y OR DEA TH. SR-18 INDEX NUMBER P ART NUMBER DESCRIPTION 1 13346 CASING SIDE ASSEMBL Y – LEFT 2 SR-068 CASING BACK 3 R-2313 PIEZO IGNITOR 4 R-2324 CONTROL KNOB 5 SR-036 CONTROL ROD 6 SR-008 CASING SIDE ASSEMBL Y – RIGHT 7 SR-119 ORIF ...
-
Empire Comfort Systems SR-30 - page 19
16942-5-0907 Page 19 SR-6 P AR TS VIEW ...
-
Empire Comfort Systems SR-30 - page 20
16942-5-0907 Page 20 SR-10 P AR TS VIEW ...
-
Empire Comfort Systems SR-30 - page 21
16942-5-0907 Page 21 SR-18 P AR TS VIEW ...
-
Empire Comfort Systems SR-30 - page 22
16942-5-0907 Page 22 SR-30 P AR TS VIEW ...
-
Empire Comfort Systems SR-30 - page 23
16942-5-0907 Page 23 INST ALLING OPTIONAL BLOWER SRB-18 OR SRB-30 If heater is installed onto the wall, in order to install the optional blower, the heater must be removed from the wall. If heater is installed on op - tional floor stand there is adequate access area available to install the optional blower . 1. T urn “OFF” gas supply to the he ...
-
Empire Comfort Systems SR-30 - page 24
16942-5-0907 Page 24 Wiring The appliance, when installed , must be electr ically grounde d in accordance with local codes or , in the absence of local codes, with the National Electri - cal Code, ANSI/NFP A 70, if an external electrical source is utilized. This appliance is equipped with a three-prong [grounding] plug for your protec - tion agains ...
Hai una domanda su Empire Comfort Systems SR-30?
Utilizza il modulo sottostante
Se non hai risolto il problema con Empire Comfort Systems SR-30 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Empire Comfort Systems SR-30 è probabile che voglia condividere il modo di risolverlo.