Manuale per l’uso Dayton 5S1792

24 pagine 0.56 mb
Scarica

Vai alla pagina of 24

Summary
  • Dayton 5S1792 - page 1

    Operating Instructions & Parts Manual Dayton Portable Oil-Fir ed Heaters ® Form 5S1792 Please read and save these instructions. Read car efully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failur e to comply with instructions could result in ...

  • Dayton 5S1792 - page 2

    Dayton Operating Instructions and Parts Manual 2 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Product Identification Figure 4 – Models 3E218F and 3E219F Power Cord Fuel Cap Fan Guard Figure 3 – Models 2E510F and 2E511F Hot Air Outlet Fan Guard Fuel T ank Fuel Cap Power Cord Side Cover Fuel T ank Air Fil ...

  • Dayton 5S1792 - page 3

    3 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® General Safety Information Make certain you read and understand all warnings. Keep these instructions for reference. They are your guide to safe and proper operation of this heater . Safety information appears through- out these instructions. ...

  • Dayton 5S1792 - page 4

    Dayton Operating Instructions and Parts Manual 4 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F General Safety Information (Continued) Figure 5 - Cr oss Section Operational View Clean Heated Air Out Air For Fuel System Air For Combus- tion and Heating Fuel Fuel Filter Air Line T o Burner Ignition Control Asse ...

  • Dayton 5S1792 - page 5

    5 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® Assembly (For Models 3E218F and 3E219F Only) These models are furnished with wheels and handles. Wheels, handles, and the mounting hardware are found in the shipping carton. TOOLS NEEDED • Medium Phillips Screwdriver • 3/8" Open or A ...

  • Dayton 5S1792 - page 6

    Dayton Operating Instructions and Parts Manual 6 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Never service heater while it is plugged in, operating, or hot. Sever e burns and electrical shock can occur . Maintenance UPPER SHELL REMOV AL 1. Remove screws along each side of heater using 5/16" nut-driver ...

  • Dayton 5S1792 - page 7

    7 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® Maintenance (Continued) 5. Remove pressure gauge. Replace pressure gauge plug in filter end cover . Pump Model Pressur e 2E510F 3.0 psi 2E511F 3.4 psi 3E218F 5.1 psi 3E219F 5.9 psi Figure 12 - Pr essure Gauge Plug Removal Pressure Gauge Plug ...

  • Dayton 5S1792 - page 8

    Dayton Operating Instructions and Parts Manual 8 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Maintenance (Continued) IGNITOR 1. Remove upper shell and fan guard (See page 6). 2. Remove fan (See page 6). 3. Remove 4 side cover screws with a 5/16" nut driver . Remove side cover (See Figures 14 and 15). ...

  • Dayton 5S1792 - page 9

    9 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® Maintenance (Continued) NOZZLE 1. Remove upper shell (See page 6). 2. Remove fan (See page 6). 3. Remove fuel and air line hoses from nozzle assembly (See Figure 18 or 19). 4. T urn nozzle assembly 1/4 turn to left and pull toward motor to re ...

  • Dayton 5S1792 - page 10

    Dayton Operating Instructions and Parts Manual 10 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Figure 25 - Gap Adjusting Scr ew Locations Maintenance (Continued) 5. Remove pump plate. 6. Remove rotor , insert, and blades. 7. Check for debris in pump. If debris is found, blow out with com- pressed air . 8. I ...

  • Dayton 5S1792 - page 11

    11 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® Never service heater while it is plugged in, operating, or hot. Sever e burns and electrical shock can occur . Pr eventative Maintenance Schedule Fuel tank Flush every 150-200 hours of operation or as needed See Storing, T ransporting, or Sh ...

  • Dayton 5S1792 - page 12

    Dayton Operating Instructions and Parts Manual 12 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P .O. Box 3074 1657 Shermer Road Nort ...

  • Dayton 5S1792 - page 13

    13 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® Ref. Part 2E510F 2E511E No. Description Number Qty . Qty. Ref. Part 2E510F 2E511F No. Description Number Qty . Qty. Ref. Part 2E510F 2E511F No. Description Number Qty . Qty . 11 Pressure Relief Spring M10993-1 1 1 12 Plug M22997 1 1 13 1/4&q ...

  • Dayton 5S1792 - page 14

    Dayton Operating Instructions and Parts Manual 14 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P .O. Box 3074 1657 Shermer Road Nort ...

  • Dayton 5S1792 - page 15

    15 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® 1 Handle M51104-01 1 1 2 Upper Shell 098511-67 1 1 3 #10-16 x 3/4" Screw * M11084-29 2 2 4 #10-16 x 1/2" Screw * M15823-27 6 6 5 Combustion Chamber 098512-58 1 — 098512-50 — 1 6 #6-32 x 3/8" Screw * M10908-2 2 2 7 Photocel ...

  • Dayton 5S1792 - page 16

    Dayton Operating Instructions and Parts Manual 16 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Please provide following information: -Model number -Serial number (if any) -Part description and number as shown in parts list Address parts correspondence to: Grainger Parts P .O. Box 3074 1657 Shermer Road Nort ...

  • Dayton 5S1792 - page 17

    17 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® (*) Standard hardware item, available locally . ( ∆ ) Not shown. (†) Not available as an assembly , see page 13. Ref. Part 2E510E 2E511E No. Description Number Qty . Qty. Ref. Part No. Description Number Qty . 22 Rubber Bushing M10990-3 ...

  • Dayton 5S1792 - page 18

    Dayton Operating Instructions and Parts Manual 18 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Figure 33 - Repair Parts Illustration for Model 3E219F 1 2 3 23 19 9 10 16 11 12 15 25 26 27 24 28 29 20 22 21 30 31 17 14 14 32 33 34 35 13 18 5 4 6 7 8 38 37 39 36 3E219F Please provide following information: -M ...

  • Dayton 5S1792 - page 19

    19 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® Ref. Part No. Description Number Qty . Ref. Part No. Description Number Qty . 1 Upper Shell (Service part 098511-292 1 will be black) 2 #10-16 x 1/2" Screw * M15823-27 8 3 Combustion Chamber 098512-74 1 4 Photocell Bracket 103971-01 1 5 ...

  • Dayton 5S1792 - page 20

    Dayton Operating Instructions and Parts Manual 20 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Repair Parts List for Handle and Wheel Gr oup Models 3E218F and 3E219F 3 4 5 8 7 6 2 1 Ref. Part Number No. Description 3E218F 3E219F Qty. 1 Front Handle HA2203 HA2204 1 2 Rear Handle HA2203 HA2204 1 3 #10 - 24 x ...

  • Dayton 5S1792 - page 21

    21 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® Wiring Diagram Figure 35 - Wiring Diagram, Models 2E510F and 2E511F Blue Photocell Power Plug 120V/60Hz Ignitor Ignitor Blue White Red Green Motor White Black Gray Gray Photocell Photocell Ignitor Motor Return 120V (L1) Motor Main AC Neutral ...

  • Dayton 5S1792 - page 22

    Dayton Operating Instructions and Parts Manual 22 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F T roubleshooting Chart Possible Cause(s) Corrective Action Never service heater while it is plugged in, operating, or hot. Severe burns and electrical shock can occur . Motor does not start five seconds after heat ...

  • Dayton 5S1792 - page 23

    23 Models 2E510F , 2E511F , 3E218F , and 3E219F Dayton Operating Instructions and Parts Manual 111166-01A ® Heater ignites but ignition control assembly shuts heater off after a short period of time 1. Pump pressure incorrect 2. Dirty air intake, air output, and/or lint filter 3. Dirty fuel filter 4. Obstruction in nozzle assembly 5. Photocell as ...

  • Dayton 5S1792 - page 24

    Dayton Operating Instructions and Parts Manual 24 Dayton Portable Oil-Fir ed Heaters ® 111166-01A 2E510F , 2E511F , 3E218F , and 3E219F Manufactured for Dayton Electric Mfg. Co. Niles, Illinois 60714 111166-01 Rev . A 04/03 Version B - For Reduction G016.J ® NOT A UPC LIMITED WARRANTY DA YTON ONE-YEAR LIMITED WARRANTY . Dayton portable oil-fired ...

Fabbricante Dayton Categoria Water Heater

I documenti che otteniamo dal fabbricante del dispositivoDayton 5S1792 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Dayton
- manuali per l’uso 5S1792
- schede prodotto Dayton
- opuscoli
- o etichette energetiche Dayton 5S1792
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Dayton 5S1792.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Dayton 5S1792, manuali di manutenzione, brevi manuali o manuali utente Dayton 5S1792. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Dayton 5S1792.

Manuali per l’uso simili

Manuale completo del dispositivo Dayton 5S1792, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Dayton 5S1792 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Dayton 5S1792.

Il manuale per l’uso completo Dayton, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Dayton 5S1792 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Dayton 5S1792, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Dayton 5S1792 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Dayton 5S1792 - che ci dovrebbe aiutare nei primi passi durante l'uso Dayton 5S1792
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Dayton 5S1792
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Dayton 5S1792 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Dayton 5S1792?

Utilizza il modulo sottostante

Se non hai risolto il problema con Dayton 5S1792 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Dayton 5S1792 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine