  • Acu-Rite 2007 - page 1

    Instruction Manual SAVE THIS MANU AL FOR FUTURE REFERENCE. Questions? Contact Cust omer Suppor t at ( 8 77) 22 1 - 1 25 2 or visit www . AcuRite .com. CONTENTS Unpac king Instr uctions ........... 2 P ackage Contents .................. 2 Product R egistration ............... 2 Features & Benets: Sensor ..... 2 Features & Benets: Displ ...

  • Acu-Rite 2007 - page 2

    2 Congratulations on y our new A cuRite product. T o ensure t he best possible product perf ormance, please read t his manual in its entirety and retain it for future ref erence. Unpac king Ins tructions Remo v e the protective lm t hat is applied to the LCD screen prior to using this product. Locate the t ab and peel of f to remov e. Pac kage C ...

  • Acu-Rite 2007 - page 3

    3 Features & Benets BACK OF DISPL AY UNIT 6. A-B-C Switc h ID code that must matc h sensor ’s A -B-C switc h to ensure units synchronize. 7 . Batter y Compartment 8. RESET Button Full reset to factor y defaults. 9. Integr ated Hang Hole for easy mounting. 1 0. GEO Button Set geographic region preference. 1 1 . ZONE Button Set time zone pre ...

  • Acu-Rite 2007 - page 4

    4 24 20 23 19 21 17 18 22 Features & Benets 1 3 6 2 7 4 9 8 5 10 11 12 14 15 13 16 28 29 31 30 27 26 25 ...

  • Acu-Rite 2007 - page 5

    5 DISPL AY UNIT 1 . Day of t he Week 2. Current Outdoor Temperature Arrow icon indicates direction temperature is trending. 3. Outdoor High T emperature Record Indicates highest outdoor tem perature recorded since midnight. 4. Outdoor Low T emperature Record Indicates lowest outdoor temperature recorded since midnight. 5. Current Outdoor Humidity A ...

  • Acu-Rite 2007 - page 6

    6 SETUP Set the A-B-C Switc h The A -B-C switc h is located inside the batt er y compar tment. It can be set to A , B or C. How ev er , you must select the same letter c hoices for bot h the sensor and the displa y unit in order for the units to sync hronize. Install or Replace Batteries AcuRite recommends high quality alkaline or lithium batter ie ...

  • Acu-Rite 2007 - page 7

    7 PLEASE DISPOSE OF OLD OR DEFECTIVE BATTERIES IN AN ENVIRONMENT ALL Y SAFE WAY AND IN ACCORDANCE WITH Y OUR LOCAL LAWS AND REGUL ATIONS. BA TTERY SAFETY : Clean the battery contacts and also those of the device prior to battery installation. Remove batteries from equipment which is not to be used for an extended period of time. Follow the polarity ...

  • Acu-Rite 2007 - page 8

    8 Setup: Geog raphic Region Select your geogr aphic region according to the map (pictured r ight) by pr essing the “GEO” button, located on t he bac k of the unit in the batt er y compar tment. The letters f or eac h corresponding GEO region are sho wn on the display screen. Geographic region must be set in order for Precision Forecasting to fu ...

  • Acu-Rite 2007 - page 9

    9 AUTO DIM MODE: Automatically adjusts display br ightness based on time of day & year . MARCH 1 1- NO VEMBER 4 6:00 a.m. - 9:00 p.m. = 1 00% br ightness 9:0 1 p.m. - 5:59 a.m.= 30% brightness NOVEMBER 5 - MAR CH 1 0 7 :30 a.m. - 7 :00 p.m.= 1 00% brightness 7 :0 1 p.m. - 7 :29 a.m. = 30% br ightness Display Bac klight Settings This weather sta ...

  • Acu-Rite 2007 - page 10

    10 Placement for Maximum Accuracy AcuRite sensors are sensitive to surrounding envir onmental conditions. Proper placement of bot h the display unit and outdoor sensor are cr itical to the accuracy and perf ormance of t his product. Display Unit Placement Place display unit in a dr y area free of dir t and dust. Display stands upright f or tablet o ...

  • Acu-Rite 2007 - page 11

    11 Using t he Weather S tation Precision Weat her Forecas ting AcuRite’s Precision Forecasting pr ovides y our personal forecast of morning, noon & night (4 hour , 4 to 8 hour and 8 to 1 2 hour) weat her conditions. The patent-pending tec hnology combines regional weather patter ns with dat a measured b y a sensor in your y ard. It gener ates ...

  • Acu-Rite 2007 - page 12

    12 Troubleshooting No outdoor sensor reception no bars If the wireless signal indicator shows no bars: • Relocate t he display unit and/or the outdoor sensor . The units must be within 330 f t (1 00 m) of each ot her . • Make sure both units are placed at least 3 fee t (.9 m) away from electronics that may inter f ere with t he wireless communi ...

  • Acu-Rite 2007 - page 13

    13 Troubleshooting Inaccurate for ecast • W eather Forecast icons predict conditions for the future, not current conditions. • Forecast will be blank for rst 4 hours af ter batter y installation. • Make sure y our GEO region is correct. If y ou live close to a region border , tr y t esting both regions to see whic h generates the most appr ...

  • Acu-Rite 2007 - page 14

    14 Replace Intelli-T ime Cloc k Batter y Intelli-T ime tec hnology is pow ered b y a pre-installed coin-cell batter y t hat stores the time and dat e settings. The batter y has a shelf lif e of sev eral y ears. T o replace t he Intelli-T ime batter y: 1 . Locate t he coin cell batter y compar tment door on t he back of t he display unit. Unscrew an ...

  • Acu-Rite 2007 - page 15

    15 Specications TEMPERA TURE RANGE Outdoor: -40 º F to 1 58 º F; -40 º C to 70 º C Indoor: 32 º F to 1 22 º F; 0 º C to 50 º C HUMIDITY RANGE Outdoor: 1% to 99% RH Indoor: 1% to 99% RH WIRELESS RANGE 330 f t / 1 00 m depending on home constr uction materials OPERA TING FREQUENCY 433 MHz POWER Display: 5v power adapter 3 x AA alkaline bat ...

  • Acu-Rite 2007 - page 16

    16 At AcuRite, we proudly uphold our commitment to quality tec hnology . Chaney Instrument Co. warrants that all products it manufactures to be of good material and workmanship, and to be free of defects when properly installed and operated for a period of one year from the date of purchase. W e recommend t hat you visit us at www .AcuRite.com for ...

  • Acu-Rite 2007 - page 17

    17 ...

  • Acu-Rite 2007 - page 18

    ...

  • Acu-Rite 2007 - page 19

    ...

  • Acu-Rite 2007 - page 20

    ©Chaney Instrument Co. All rights reserved. AcuRite is a registered trademark of the Chaney Instrument Co., Lake Geneva, WI 53147. All other trademarks and copyrights are the property of their respective owners. AcuRite uses patented technology . Visit www.AcuRite.com/patents for details. Printed in China 02007 INST 052 1 14 It’ s more than accu ...

Fabbricante Acu-Rite Categoria Weather Radio

I documenti che otteniamo dal fabbricante del dispositivoAcu-Rite 2007 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Acu-Rite
- manuali per l’uso 2007
- schede prodotto Acu-Rite
- opuscoli
- o etichette energetiche Acu-Rite 2007
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Acu-Rite 2007.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Acu-Rite 2007, manuali di manutenzione, brevi manuali o manuali utente Acu-Rite 2007. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Acu-Rite 2007.

Manuali per l’uso simili

Manuale completo del dispositivo Acu-Rite 2007, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Acu-Rite 2007 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Acu-Rite 2007.

Il manuale per l’uso completo Acu-Rite, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Acu-Rite 2007 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Acu-Rite 2007, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Acu-Rite 2007 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Acu-Rite 2007 - che ci dovrebbe aiutare nei primi passi durante l'uso Acu-Rite 2007
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Acu-Rite 2007
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Acu-Rite 2007 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Acu-Rite 2007?

Utilizza il modulo sottostante

Se non hai risolto il problema con Acu-Rite 2007 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Acu-Rite 2007 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)