Manuale per l’uso Clarion UNGO MS5500

32 pagine 0.02 mb
Scarica

Vai alla pagina of 32

Summary
  • Clarion UNGO MS5500 - page 1

    installation_MS5500.qxd 12/6/99 11:59 AM Page 1 ...

  • Clarion UNGO MS5500 - page 2

    installation_MS5500.qxd 12/6/99 11:59 AM Page 2 ...

  • Clarion UNGO MS5500 - page 3

    1. Before Y ou Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 1 2. Installation T ips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 2 3. Mounting Components Main Unit . . . . . . . . . . . . . . . . ...

  • Clarion UNGO MS5500 - page 4

    installation_MS5500.qxd 12/6/99 11:59 AM Page 4 ...

  • Clarion UNGO MS5500 - page 5

    MS5500 Installation Manual - Page 1 1. Be sure to read the manual thoroughly before beginning the installation to ensure a proper understanding of the MS5500 and its functions. 2. V erify system contents: ❑ Main Unit ❑ Two 3-Button Remote T ransmitters ❑ Siren ❑ Logic Sensor II ❑ Harnesses • 14-Pin main harness • 4-Pin auxiliary funct ...

  • Clarion UNGO MS5500 - page 6

    Page 2 - MS5500 Installation Manual 1. Use a V olt / Ohm meter to test all wires. Do not use a test light. 2. Good power and ground connections are essential for proper operation. 3. Route all wires from the engine compartment to the interior of the vehicle through a grommet and use electrical tape and split loom tubing for protection. 4. When addi ...

  • Clarion UNGO MS5500 - page 7

    MS5500 Installation Manual - Page 3 Main Unit The main unit should be mounted in the interior of the vehicle. Do not mount the main unit in the engine compartment. For maximum security , avoid mounting the main unit where it will be easily accessible to a thief. If you are mounting the unit under the dash board, be sure to mount the unit as high as ...

  • Clarion UNGO MS5500 - page 8

    Page 4 - MS5500 Installation Manual EXT2 Extended Range Antenna (optional) The optional EXT2 is a tuned, coaxial antenna, designed to be used with the MS5500 security system to increase transmitter range. When properly installed, the EXT2 will add greater installation flexibility to the system, allowing the antenna to be placed high in the vehicle ...

  • Clarion UNGO MS5500 - page 9

    MS5500 Installation Manual - Page 5 Mounting For Shock and Motion Sensitivity Mounting For Shock Sensitivity Only Motion Sensitivity Front/Rear Side to Side Position Best Best Good Least Least Good Good Good Override Switch Mount the Override Switch in a location near the driver where it is easily accessible but not plainly visible. Plug the blue o ...

  • Clarion UNGO MS5500 - page 10

    Page 6 - MS5500 Installation Manual Logic Sensor II Override Switch S tatus LED Wiring Diagram installation_MS5500.qxd 12/6/99 11:59 AM Page 6 ...

  • Clarion UNGO MS5500 - page 11

    MS5500 Installation Manual - Page 7 14-Pin Main Harness Pin 1 - BLACK: Ground. Connect to a solid chassis ground. Be sure to use a ring connector of proper size. Scrape away the paint at the grounding point. Pin 2 - RED: Main Power (+12v) input [3A fuse] Connect to constant +12v . A clean source of power is essential. This connection can be made at ...

  • Clarion UNGO MS5500 - page 12

    Page 8 - MS5500 Installation Manual Pin 1 1 - BLUE: Starter Defeat Normally Closed (-) output Provides a negative output while the alarm is Armed and during alarming to disable the vehicle’s st arter circuits. Connect to the provided S tarter Kill Relay socket as shown. In this configuration, the vehicle’s st arter will be disabled only when th ...

  • Clarion UNGO MS5500 - page 13

    MS5500 Installation Manual - Page 9 Pin 14 - YELLOW/white: Auxiliary Function 1 negative output Provides negative (-) output. Output will stay on for as long as the Button is pressed. 4-Pin Auxiliary Function Harness Pin 1 - YELLOW/black: Auxiliary Function 2 (-) output (resets with arm and disarm). Provides a negative output to activate a relay . ...

  • Clarion UNGO MS5500 - page 14

    Page 10 - MS5500 Installation Manual Jumper Selections Parking Light Polarity . Selects the polarity (+/-) for the output of the on-board Parking Light relay . Pin 1 + Pin 2 = positive Pin 2 + Pin 3 = negative Dome Light Polarity . Select s the polarity (+/-) for the output of the on-board Illuminated Entry/Exit relay . Pin 1 + Pin 2 = positive Pin ...

  • Clarion UNGO MS5500 - page 15

    MS5500 Installation Manual - Page 11 Accessing the Jumpers Using a flathead screwdriver , carefully press in on the access tabs on the sides of the case until the hooks release. T ake care not to push the t abs in too far or they may break. Once you have made your selections, close the case by aligning the top and button halves of the case, making ...

  • Clarion UNGO MS5500 - page 16

    Page 12 - MS5500 Installation Manual Remote T ransmitter Layout Each system comes with 2 Remote T ransmitters, pre-programmed to operate in the Ungo St andard Mode and will Arm and Disarm the system with chirp confirmation using Button 1 . T ransmitter Operating Modes The MS5500 can be configured to work with the remote transmitters in one of three ...

  • Clarion UNGO MS5500 - page 17

    MS5500 Installation Manual - Page 13 The Mode Button will change the function of Buttons 1 and 2 each time it is pressed, allowing Buttons 1 and 2 to control the system’s Auxiliary Function Outputs. Note also that the LED on the transmitter changes color each time the Mode Button is pressed to indicate the current function of Buttons 1 and 2. The ...

  • Clarion UNGO MS5500 - page 18

    Page 14 - MS5500 Installation Manual Button 1 Arms the system. This Button also locks the doors when the system is in V alet Mode. Button 2 Disarms the system and at the same time activates Auxiliary Function 1 (which unlocks the driver ’s door). This Button also unlocks the doors when the system is in V alet Mode. If the system is Armed, pressin ...

  • Clarion UNGO MS5500 - page 19

    MS5500 Installation Manual - Page 15 Adding a New T ransmitter into the System 1. T urn on the ignition. 2. Press and hold the Override switch. • The st atus LED will turn on red. 3. Within 5 seconds: Continue holding the Override switch and Press T ransmitter Button 1* For remote arming with chirp confirmation. --- or --- Release the Override sw ...

  • Clarion UNGO MS5500 - page 20

    Page 16 - MS5500 Installation Manual System Initialization and Default Reset Following this procedure will set all System Programming Parameters to factory default settings. 1. T urn on ignition. 2. After 4 seconds, press and hold Buttons 1 and 2 together for 5 seconds. The siren will emit one chirp, indicating that the reset signal was received. 3 ...

  • Clarion UNGO MS5500 - page 21

    MS5500 Installation Manual - Page 17 Programmable System Parameters 1. Ignition Controlled Door Locking. Selects whether or not the system automatically locks the doors when the ignition is turned on. When selected, the Ignition Controlled Door Locking feature will automatically lock the doors 10 seconds after the ignition key is turned on. T o pre ...

  • Clarion UNGO MS5500 - page 22

    Page 18 - MS5500 Installation Manual 2 chirps = Logic Sensor II 3 chirps = Optional sensor 4 chirps = hood/trunk When Audible T amper Alert report is turned off, the siren will emit a long chirp on disarming to indicate the system was triggered, but the zone indication will be from the status LED only . 5. Door Unlock Pulse - Single/Double. Select ...

  • Clarion UNGO MS5500 - page 23

    MS5500 Installation Manual - Page 19 the 30 seconds, the output will turn off. When the Latched or T imed outputs are activated: • Arming the system will turn off the Aux. 2 output if it was turned on while the system was disarmed. • Disarming the system will turn off the Aux. 2 output if it was turned on while the system was armed. 11 . Logic ...

  • Clarion UNGO MS5500 - page 24

    Page 20 - MS5500 Installation Manual Because of its advanced design, the Logic Sensor II can be set for Shock and Motion detection or Shock detection only . The way the sensor is mounted and the Motion Sensitivity jumper is set determines if motion is detected. See Mounting Components and Jumper Selections. Adjustment The shock sensitivity of the L ...

  • Clarion UNGO MS5500 - page 25

    MS5500 Installation Manual - Page 21 Remote Logic Sensor II Byp ass In case of extreme weather conditions such as high winds, the Logic Sensor II can be temporarily bypassed from the Remote Transmitter while the system is armed to prevent the system from false alarming. T o Bypass the Logic Sensor II: 1. With the system armed, press the Mode Button ...

  • Clarion UNGO MS5500 - page 26

    Page 22 - MS5500 Installation Manual Y ou can use this chart to quickly identify and interpret the MS5500 system’s chirp indications and LED flashes. Reference Chart 1 chirp arming normal arming 1 + 3 chirps arming Logic Sensor II sensitivity is off 1 + 4 chirps arming door , hood, or trunk is open Double chirps while armed system triggered (Pass ...

  • Clarion UNGO MS5500 - page 27

    MS5500 Installation Manual - Page 23 Door Lock Diagrams Negative T rigger Positive T rigger V oltage Reversal Aftermarket Actuators V acuum Lock System White/green = (-) Lock / +12v Unlock White/blue = (-) Unlock / +12v Lock installation_MS5500.qxd 12/6/99 11:59 AM Page 23 ...

  • Clarion UNGO MS5500 - page 28

    Page 24 - MS5500 Installation Manual DRIVER DOOR ACTU AT OR Yello w/white wire (-) AUX. 1 output CUT P ASSENGER DOOR ACTU AT ORS FA CTOR Y DOOR LOCK MODULE White/blue wire (-) UNLOCK White/green wire (-) LOCK (-) Door Lock wire (-) Door Unlock wire 15A FUSE CONNECT TO +12V LOCK/UNLOCK SWITCH DRIVER DOOR ACTU AT OR Yello w/white wire (-) AUX. 1 outp ...

  • Clarion UNGO MS5500 - page 29

    MS5500 Installation Manual - Page 25 The following are some suggested uses for the programmable Auxiliary Function 2 Output. T ech Tip s Remote Control of Audio System (Latched Operating Mode) This enables the user to listen to the vehicle’s audio or video system for extended periods without need of the vehicle’s ignition key . When the Aux 2 f ...

  • Clarion UNGO MS5500 - page 30

    Page 26 - MS5500 Installation Manual Notes installation_MS5500.qxd 12/6/99 11:59 AM Page 26 ...

  • Clarion UNGO MS5500 - page 31

    MS5500 Installation Manual - Page 27 installation_MS5500.qxd 12/6/99 11:59 AM Page 27 ...

  • Clarion UNGO MS5500 - page 32

    Ungo Security Corporation A Clarion Company 661 West Redondo Beach Blvd. Gardena, CA 90247 800-Go-Clarion www .clarionmultimedia © Ungo Security Corporation, Gardena, CA 98-MS5500-00 Rev . 1 (1 1/98) MS5500 Wiring Diagram installation_MS5500.qxd 12/6/99 11:59 AM Page 28 ...

Fabbricante Clarion Categoria Automobile Alarm

I documenti che otteniamo dal fabbricante del dispositivoClarion UNGO MS5500 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Clarion
- manuali per l’uso UNGO MS5500
- schede prodotto Clarion
- opuscoli
- o etichette energetiche Clarion UNGO MS5500
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Clarion UNGO MS5500.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Clarion UNGO MS5500, manuali di manutenzione, brevi manuali o manuali utente Clarion UNGO MS5500. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Clarion UNGO MS5500.

Manuali per l’uso simili

Manuale completo del dispositivo Clarion UNGO MS5500, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Clarion UNGO MS5500 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Clarion UNGO MS5500.

Il manuale per l’uso completo Clarion, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Clarion UNGO MS5500 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Clarion UNGO MS5500, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Clarion UNGO MS5500 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Clarion UNGO MS5500 - che ci dovrebbe aiutare nei primi passi durante l'uso Clarion UNGO MS5500
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Clarion UNGO MS5500
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Clarion UNGO MS5500 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Clarion UNGO MS5500?

Utilizza il modulo sottostante

Se non hai risolto il problema con Clarion UNGO MS5500 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Clarion UNGO MS5500 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)