Manuale per l’uso Bradford White 238-16152-00F

23 pagine 1.34 mb
Scarica

Vai alla pagina of 23

Summary
  • Bradford White 238-16152-00F - page 1

    238 - 16152 - 00F REV 12/03 COMMERCIAL ELECTRIC WATER HEATER La version espanola de estas instrucciones se puede obtener al escribirle a la fábrica cuyo nombre aparece in la placa de especificaciones. A Spanish language version of these instructions is a vailable by contacting the manufacturer listed on the rating plate. THE WARRANTY ON THIS WATER ...

  • Bradford White 238-16152-00F - page 2

    2 CONGRATULATIONS! You have just purchased one of the finest water heaters on the market toda y! This installation, operation and instruction manual will explain in detail the installation and maintenance of your new Commercial Electric Water Heater. We at Bradford White strongly recommend that you contact a plumbing professional for the installa t ...

  • Bradford White 238-16152-00F - page 3

    3 TABLE OF CONTENTS General Information ................................................................... 4 Installation .................................................................................... 5 Locating The Water Heater .................................................... 5 Water Connections ......................................... ...

  • Bradford White 238-16152-00F - page 4

    4 GENERAL INFORMATION The design of this electric water has been listed with Underwriters’ Laboratories, Inc. (UL) as complying with UL standard UL1453. This water heater must be installed in accordance with local codes. In the absence of local codes, install this water heater in accordance with the N.E.C. Reference Book (latest edition). The war ...

  • Bradford White 238-16152-00F - page 5

    5 General Information continued - A sacrificial anode(s) is used to extend tank life. Removal of any anode, for any reason, will nullify the warranty. In areas wh ere water is unusually active, an odor may occur at the hot water faucet due to a reaction between the sacrificial anode and impurities in the water. If this should happen, an alternative ...

  • Bradford White 238-16152-00F - page 6

    6 INSTALLATIO N Locating The Water Heater This water heater must NOT be installed in any location where gasoline or flammable vapors are likely to be present, unless the installation is such to eliminate the ignition of gasoline or flammable vapors. The location for the installation of this water hea ter is of utmost importance. Before installing t ...

  • Bradford White 238-16152-00F - page 7

    7 valve will not result in damage to the area adjacent to the water heater or to lower floors of the structure. When such locations cannot be avoided, a suitable drain pan must be installed under the water heater. The drain pan must be no greater than 1 1/2 in. (3.8 cm) deep and have a minimum length and width of at least 4 in. (10.2 cm) measured f ...

  • Bradford White 238-16152-00F - page 8

    8 the water connections to the water heater. After the pressure has been relieved, close the faucet. The cold water inlet line connects to the inlet nipp le at the base of the water heater. The hot water outlet line connects to the nipple on top of the water heater. The fittings at the cold water inlet and hot water outlet are dielectric waterway f ...

  • Bradford White 238-16152-00F - page 9

    9 Water Connections continued - WARNING For protect ion against excessive temperatures and pressure, install temperature and pressure protective equipment required by local codes, but not less than a combination temperature and pressure relief valve certified by a nationally recognized testing laboratory th at maintains periodic inspection of produ ...

  • Bradford White 238-16152-00F - page 10

    10 Water Connections continued - WARNING Hydrogen gas can be produced in a hot water system served by this water heater that has not been used for a long period of time (generally two weeks or more). Hydrogen gas is extremely flammable. To reduce the risk of injury under these co nditions, it is recommended that the hot water faucet be opened for s ...

  • Bradford White 238-16152-00F - page 11

    11 This water heater can deliver scalding temperature water at any faucet in the system. Be careful whenever using hot w ater to avoid scalding injury. Certain appliances, such as dishwashers and automatic clothes washers, may require increased temperature water. By setting the thermostat on this water heater to obtain increased temperature water r ...

  • Bradford White 238-16152-00F - page 12

    12 Figure 1 (Dual Temperature System With Mixing Valve) Figure 2 (Single Installation With Storage Tank Gravity Circulation) INTERNET VERSION FOR REFERENCE ONLY ...

  • Bradford White 238-16152-00F - page 13

    13 Water Connections continued - Figure 3 (Dual Water Heater Installation) INTERNET VERSION FOR REFERENCE ONLY ...

  • Bradford White 238-16152-00F - page 14

    14 Electrical Connections Before any electrical connections are made, be sure that the water heater is full of water and that the manual shut - off valve in the cold water supply line is open. If the heating elements are not completely immersed in w ater at all times, they will be damaged (burned - out) if energized for even a short period of time. ...

  • Bradford White 238-16152-00F - page 15

    15 kW 208V 240V 277V 380V 415V 480V Input 1Ø 3Ø 1Ø 3Ø 1Ø 3Ø 3Ø 1Ø 3Ø 6 29 17 25 14 22 9 8 12 7 9 43 25 38 22 32 14 13 19 11 12 58 33 50 29 43 19 17 25 14 13.5 65 38 56 32 49 21 19 28 16 15 72 42 63 36 54 23 21 31 18 18 87 50 75 43 65 28 25 38 22 24 115 67 100 58 87 37 34 50 29 27 130 75 113 65 97 41 38 56 32 30 144 83 125 72 108 46 42 63 3 ...

  • Bradford White 238-16152-00F - page 16

    16 Before closing the switch to allow electric current to flow to the water heater, make certain that the water heater is full of water and that the cold water inlet valve is open. Complete failure of the heating elements will result if they are not totally immersed in water at all times. When the switch is closed, the operation of this electric wa ...

  • Bradford White 238-16152-00F - page 17

    17 directly contacts the water heater tank surface (see Figure 4). The second type, immersed type are immersed within the water heater tank and uses contactor type rel ays. Before any work is done on the water heater, disconnect all power to the water heater by opening the switch at the main electrical circuit breaker or fuse box. Before adjusting ...

  • Bradford White 238-16152-00F - page 18

    18 Figure 4 Figure 5 MAINT ENANCE INTERNET VERSION FOR REFERENCE ONLY ...

  • Bradford White 238-16152-00F - page 19

    19 Shut off the electric power whenever the water supply to the water heater is off. Shut off the electric power and water supply, drain the heater completely to prevent freezing whenever the building is left unoccupied during the cold weather months. In order to insure efficient operation and long tank life, drain the water heater at least once a ...

  • Bradford White 238-16152-00F - page 20

    20 3. At least once a year, check the combination temperature and pressur e relief valve to insure that the valve has not become encrusted with lime. Lift the lever at the top of the temperature - pressure relief valve several times until the valve seats properly without leaking and operates freely. 4. If the combination tempera ture and pressure r ...

  • Bradford White 238-16152-00F - page 21

    21 For faster and be tter service, please provide the part name, model, and serial number(s) of the water heater(s) when ordering parts. READ THE WARRANTY FOR A FULL EXPLANATION OF THE LENGTH OF TIME THAT PARTS AND THE WATER HEATER ARE WARRANTED. Complete the following information and retain for future reference: Model No: Serial No: Service Phone ...

  • Bradford White 238-16152-00F - page 22

    22 NOTES INTERNET VERSION FOR REFERENCE ONLY ...

  • Bradford White 238-16152-00F - page 23

    23 NOTES INTERNET VERSION FOR REFERENCE ONLY ...

Fabbricante Bradford White Categoria Water Heater

I documenti che otteniamo dal fabbricante del dispositivoBradford White 238-16152-00F possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Bradford White
- manuali per l’uso 238-16152-00F
- schede prodotto Bradford White
- opuscoli
- o etichette energetiche Bradford White 238-16152-00F
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Bradford White 238-16152-00F.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Bradford White 238-16152-00F, manuali di manutenzione, brevi manuali o manuali utente Bradford White 238-16152-00F. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Bradford White 238-16152-00F.

Manuali per l’uso simili

Manuale completo del dispositivo Bradford White 238-16152-00F, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Bradford White 238-16152-00F dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Bradford White 238-16152-00F.

Il manuale per l’uso completo Bradford White, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Bradford White 238-16152-00F - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Bradford White 238-16152-00F, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Bradford White 238-16152-00F che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Bradford White 238-16152-00F - che ci dovrebbe aiutare nei primi passi durante l'uso Bradford White 238-16152-00F
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Bradford White 238-16152-00F
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Bradford White 238-16152-00F in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Bradford White 238-16152-00F?

Utilizza il modulo sottostante

Se non hai risolto il problema con Bradford White 238-16152-00F con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Bradford White 238-16152-00F è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)