Manuale per l’uso Uniden USC 2500XL T

36 pagine 2.17 mb
Scarica

Vai alla pagina of 36

Summary
  • Uniden USC 2500XL T - page 1

    , , ,--- "--",.,,- ,, ,,- USC 2500XL T I I I I j I I I' i , , I 400-Channel Programmable Hand-Held Auto Scanner OPERATING GUIDE : ==~- ,-, .. --- " ...

  • Uniden USC 2500XL T - page 2

    - .---..- ---.-. 1 PRECAUTIONS Before you read anything else, please observe the following: WARNING! Uniden DOES NOT represent this unit to be waterproof. To reduce the risk of fire or electrical shock, DO NOT expose this unit to rain or moisture. NICKEL-CADMIUM BATTERY WARNING . This equipment contains a Nickel-Cadmium Battery . . The Nickel-Cadmi ...

  • Uniden USC 2500XL T - page 3

    I -- t-. Table of Contents AboutYourNewUBC2500XLT... 2 WhatisScanning? 2 Types of Communication 2 Where to Obtain More Information. . . . . . . . . . . . . . . . . . . . 3 Unpacking 3 Optional Accessories 3 FeatureHighllghts 4 Controls and Indicators 5 TopView 5 FrontView 6 LCDDisplay 12 I I I I I I I Setup 13 Installing the Battery Pack 13 Charg ...

  • Uniden USC 2500XL T - page 4

    - ~- c --------.------.----.----.. About Your New UBC 2500XLT The UBC 2500XL T is a brand new state-of-the-art information radio with automatic scanning capabilities. It can store frequencies such as police, fire/emergency, marine, air, weather frequencies, and other broadcasts into 20 banks of 20 channels each. The new Rotary Tuner feature enables ...

  • Uniden USC 2500XL T - page 5

    - ---. Unpacking Carefully check the contents against this list: . UBC 2500XL T Auto Scanner . Rubber Antenna . AC Adaptor/Charger (AAD-2500U) . Earphone . Leather-like Carrying Case . Belt Clip . This Operating Guide If any items are missing or damaged, contact your place of purchase immediately. Please read this Operating Guide thoroughly before ...

  • Uniden USC 2500XL T - page 6

    -.., Feature Highlights . Turbo Scan This lightning-fast technology enables the UBC 2500XL T to scan and search nearly 100 channels or steps per second. Because the frequency coverage is so large (see "Technical Specifications" section for band listing), a very fast scanning system is essential. That is why we combined our latest technolo ...

  • Uniden USC 2500XL T - page 7

    --"---'-- Controls and Indicators Top View Emmal Speaker I Channel! Frequencyl Lock Earphone Antenna Connec1Dr OriOlf Volume Rotary Tuner Squelch EXTERNAL When using an optional External Speaker SPEAKER JACK system, connect the External Speaker plug here. EARPHONE JACK ANTENNA CONNECTOR Plug the earphone into this jack for private listeni ...

  • Uniden USC 2500XL T - page 8

    Front View leD DltpIIy SCAN Kay MAMlAL Kay WX (WelCherMode) Key DLY (DelIY) Key LJO(Lock Out) Kay PAl (PrIority) Key a D 0000000 0000000 0000000 0000000 0000000 6 =r: ~ -.- =- ..= L - 0 ICAH J (jj' (ti (:'" -,...- ',.., :> (Y i$'::" ... 0-1 " , :..::!.i '.". -"":...,, ,".," ,....&q ...

  • Uniden USC 2500XL T - page 9

    ------ Press [SCAN] to start scanning all programmed channels that are not locked out. ("SCAN" appears on the display during scanning.) In Scan or Search Mode, press [MANUAL] to stop scanning or searching, and to select a channel. After you stop the scanner, press f MANUAL] again to STEP UP a channel or requency. Press and holdto rapidly ...

  • Uniden USC 2500XL T - page 10

    SPD (SpIed) Key LCK (Keypad LocII) Key CNT (COIIII) Key LHT (Ughl) Key - a D - n- n _u -u - - -_n-. ,~M"'"~', ! 0) 11 @ '1 @ 13: i o~,'n. ~ : 1 2 3: ~ , ' ,~ : @ 'C @ 1I @ '8! ~ o...">~.,, i : 4 5 6' '., " . 4 r"" ~"-, : ~ '7 t:;{. @ ": !""::" ...

  • Uniden USC 2500XL T - page 11

    SPEED KEY Press rSPD] to select the scanning speed, normar or Turbo Scan. (In Turbo Scan Mode, "TURBO" appears next to "SCAN" on the display.) At normal speed, the scanner scans 16 to 20 channels per second. In Turbo speed, the scanner scans nearly 100 channels per second. Use [CNT] to indicate the number of times the scanner st ...

  • Uniden USC 2500XL T - page 12

    LMT (LInt) K'V SIP (Slep) Key a , . : ':"':'." : , . , ::E::::::::;;::) F::,) f:::] C;:'j E::J F::~'j L;::::.J """. ,""'. 1.,.;,:: :,..:d '...,' :' ' {j)' (:~i'f (:~::;" '.' (:;f;: (;:~)' {:;~;) (~:.:: :::~;)' G~);' D SR ...

  • Uniden USC 2500XL T - page 13

    LIMIT KEY STEP KEY ENTER KEY SEARCH KEY HOLD KEY AUTO KEY I =-=-===== This key has two functions in Search Mode: (a) to step down a frequency; and (b) to set the search band limits. To manually step down, press and hold [LMT]. Press and hold for more than one second to rapidly move down the frequencies. To set the lower and upper limits of the sear ...

  • Uniden USC 2500XL T - page 14

    - ---..----------- - SEND KEY LCD Display ~ when Auto Store is activated.) To stop Auto Store, press [HLD], [MANUAL], or [AUTO]. Press [SND] to transfer a displayed frequency to any open (empty) bank channel. When the bank Indicators start flashing, press the numeric keys for the selected bank. Then press [E) to complete the transfer. BANK 1 2 3 4 ...

  • Uniden USC 2500XL T - page 15

    '- Setup The UBC 2500XL T comes with a rechargeable Nickel-Cadmium Battery Pack. When fully charged, this Battery Pack will supply up to 5 hours of dependable use. Before using the UBC 2500XL T for the first time, or whenever the LOW BATTERY Indicator appears on the LCD display, you should fully charge the Battery Pack. Note: When the Battery ...

  • Uniden USC 2500XL T - page 16

    To fully charge the battery, leave the Adaptor/Charger connected for 14 to 16 hours. Note: You can operate the unit while the battery is charging. 3. When charging is complete, disconnect the Adaptor/ Charger from the AC outlet and from the Battery Pack. Note: Disconnect the AC Adaptor/Charger from the unit during a power failure. Mounting the Flex ...

  • Uniden USC 2500XL T - page 17

    ..-----..---- Scanning Overview Note: Before operating the uac 2500XL T for the first time, make sure you have fully charged the Battery Pack. 1. Before turning on the scanner, rotate the Squelch Control fully clockwise. 2. Turn the scanner on by rotating the On-OttNolume Control clockwise until you hear a click. 3. Adjust the volume to a comfortab ...

  • Uniden USC 2500XL T - page 18

    Programming Channels Before you can scan, you must program the channels within a bank. You can store one frequency per channel, up to 400 channels. Each time you store a frequency, the list of scanning frequencies in the bank is automatically sorted by frequency number. This unique Auto Sort feature enables faster scanning. When you manually step t ...

  • Uniden USC 2500XL T - page 19

    -- 6. Press [E] to store the entry. . If the frequency is already stored in another channel, the other channel will appear on the display. To resolve the conflict, just enter another frequency for the cu"ently selected channel. (Later, we'll discuss how to delete a stored frequency.) . Any frequency already stored in a channel will automa ...

  • Uniden USC 2500XL T - page 20

    6. Press [E]. The frequency is now programmed into the current channel. 7. You are finished, and may now skip to the next section. Press [SND] twice. When the channel number blinks, enter the new channel number using the numeric keys. Press [HLD] to see if the selected channel is already programmed. 8. If the selected channel already has a stored f ...

  • Uniden USC 2500XL T - page 21

    --~- ~----.--- ~ramming With SEARCH 'ch feature enables you to rapidly search for active jes within the specified band limits. When an Ig frequency is found, you can store it into a channel t procedure below. ress [MANUAL] to stop scanning. Jse the numeric keypad to enter the lower limit and Ipper limit of the band to be searched. (See "T ...

  • Uniden USC 2500XL T - page 22

    ,,---------- "" '"'.". "- " -- 5. To store the displayed frequency into: (a) the current channel (b) another selected channel (c) another bank's open (empty) channel Please refer to Step 5 of the previous section. The procedures are the same. To leave the Search Mode, press [MANUAL] or [SCAN]. D. Program ...

  • Uniden USC 2500XL T - page 23

    Select the bank(s) to be programmed. The indicators of the selected banks stop flashing. Note: If the selected bank is full, that is, all 20 channels are programmed, "FULL:' appears on the display. In this case, select another bank. Press [SRC] to start programming. On the display, only the indicators of the selected banks remain. The ind ...

  • Uniden USC 2500XL T - page 24

    ---- Deleting a Stored Frequency To delete a frequency from a channel: 1. Display the channel and frequency that is to be deleted. 2. Press [0] on the numeric keypad. 3. Press [E]. The current channel is erased, and the display shows "000.000". 22 -- ...4~~ ===-==-= =--.- i&i :; r --L... ..-.............- ...

  • Uniden USC 2500XL T - page 25

    Scann ing 1. Turn on the power, or press [SCAN] to start scanning. Note: When the scanner is turned on, it is automati- cally in Scan Mode. The indicators for the selected banks (1 through 20) appear on the display. The indicator of the bank currently being monitored flashes. While the UBC 2500XL T is scanning, the "SCAN" message moves ac ...

  • Uniden USC 2500XL T - page 26

    Weather Channel Scanning The USC 2500XL T allows you to search for your local weather channel. Press [WX] to find the active weather channel in your area from 7 preprogrammed channels. "wx" appears on the display. To exit Weather Mode, press [SRC], [SCAN], or [MANUAL]. It is possible that your area is covered by more than one weather stat ...

  • Uniden USC 2500XL T - page 27

    --- ---------- Customizing Scanner Operation Setting the Scanning Speed Press [SPD] to select the scanning speed, normal or Turbo Scan. (In Turbo Scan Mode, "TURBO" appears on the display next to "SCAN".) In Normal Scan Mode, the UBC 2500XL T scans 16 to 20 channels per second. In Turbo Scan Mode, the unit scans nearly 100 chann ...

  • Uniden USC 2500XL T - page 28

    Channel Lock Out You can lock out any programmed channels (including Priority Channels) so they will not be scanned, if desired. Note: Locking out a programmed channel does not erase the frequency in the channel. This feature is active in Manual Mode or Scan Mode. To lock out a channel: Press [LlO] when the scanner is on a channel you do not want t ...

  • Uniden USC 2500XL T - page 29

    --~------- Setting Up Priority Channels When you assign "priority" to a bank channel, you designate one bank channel as your most important channel. During scanning the UBC 2500XL T works like a "dual watch" function. It starts "sampling" or keeping track of the activity on the Priority Channel while listening to other ...

  • Uniden USC 2500XL T - page 30

    Using COUNT to Monitor Channel Activity To determine the amount of channel activity during a scanning session, use the Count feature. It counts the number of times scanning stops on an active channel. To activate the Count feature: 1. Press [SCAN], and allow the scanner to scan for about 5 to 10 minutes, or longer if desired. 2. Press [MANUAL] to s ...

  • Uniden USC 2500XL T - page 31

    .-.--- Care and Maintenance Replacing the Rechargeable Battery Pack When it is time to install a new Battery Pack, use only the one made for this scanner. Any other type of battery may damage yourunit. To replace the Battery Pack: 1. Remove the Belt Clip by lifting the tab and carefully sliding it upward and out. 2. Remove the Battery Pack by press ...

  • Uniden USC 2500XL T - page 32

    ,""."'-- Location . Ifstrong interference or electrical noise is received, relocate the scanner or its antenna away from the source of the noise. A higher elevation, if possible, may provide better reception. . Do not use the scanner in high-moisture environments such as the kitchen or bathroom. . Avoid placing the unit in direc ...

  • Uniden USC 2500XL T - page 33

    .--- ...... Troubleshooting If your UBC 2500XL T is not performing properly, try the steps listed below. If you still cannot get satisfactory results and want additional information, or to return the unit for service, please call or write the Uniden Technical Service Division. The address and phone number are listed in the Warranty (at the end of t ...

  • Uniden USC 2500XL T - page 34

    Technical Specifications Banks: WX: Search Band: Display 25 - 29 29 - 56 56 - 70 70 - 88 88 - 108 108 - 137 137 - 174 174 - 222 222 - 340 400 - 520 520 - 550 760 - 824 824 - 849 849 - 869 869 -894 894-1300 Scan Rate: Total 20 banks 7 programmed (Weather Channel) T otal12 Search bands (N FM, AM, or WFM) Default Steps 5.0 kHz 5.0 kHz 50.0 kHz 5.0 kHz ...

  • Uniden USC 2500XL T - page 35

    WARRANTY +----- I I Uniden UBC 2500XLT Scanning Receiver Australian 1 Year Warranty (Accessories are covered for 90 days only). NOTE: Please keep your sales docket as it provides evidence of warranty. WARRANTOR: Uniden Australia Pty. Limited. ACN 001 865 498 ELEMENTS OF WARRANTY: Uniden warrants to the original retail owner for the duration of this ...

  • Uniden USC 2500XL T - page 36

    unid~n~ GP) @ 1994 Uniden Australia Pty. Limited. All rights reserved. UBUEO1230DZ Printed in the Philippines --- - - -'_..--_.--.- ...

Fabbricante Uniden Categoria Scanner

I documenti che otteniamo dal fabbricante del dispositivoUniden USC 2500XL T possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Uniden
- manuali per l’uso USC 2500XL T
- schede prodotto Uniden
- opuscoli
- o etichette energetiche Uniden USC 2500XL T
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Uniden USC 2500XL T.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Uniden USC 2500XL T, manuali di manutenzione, brevi manuali o manuali utente Uniden USC 2500XL T. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Uniden USC 2500XL T.

Manuali per l’uso simili

Manuale completo del dispositivo Uniden USC 2500XL T, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Uniden USC 2500XL T dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Uniden USC 2500XL T.

Il manuale per l’uso completo Uniden, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Uniden USC 2500XL T - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Uniden USC 2500XL T, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Uniden USC 2500XL T che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Uniden USC 2500XL T - che ci dovrebbe aiutare nei primi passi durante l'uso Uniden USC 2500XL T
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Uniden USC 2500XL T
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Uniden USC 2500XL T in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Uniden USC 2500XL T?

Utilizza il modulo sottostante

Se non hai risolto il problema con Uniden USC 2500XL T con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Uniden USC 2500XL T è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)