Manuale per l’uso Watts Industries WM100SM

28 pagine 4.17 mb
Scarica

Vai alla pagina of 28

Summary
  • Watts Industries WM100SM - page 1

    OPERA TING MANU AL WA TER CONDITIONER with WM100SM v alve ® WA TER QU ALITY & CONDITIONING PRODUCTS ...

  • Watts Industries WM100SM - page 2

    2 T ABLE OF CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 General Warnings . . . . . . . . . . . . . . . . . . . . . . . . . .1 Principles Of Softening-Ion Exchange . . . . . . . . . .2 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Quick Ref erence Specifications . . . . . . . ...

  • Watts Industries WM100SM - page 3

    3 INTR ODUCTION General W arnings The control v al v e , fittings and, or b ypass are designed to accommodate minor plumbing misalignments but are not designed to suppor t the weight of a system or the plumbing. Do not use V aseline, oils, other h ydrocarbon lubricants or spra y silicone anywhere. A silicon lubr icant may be used on b lac k o-r ing ...

  • Watts Industries WM100SM - page 4

    4 INTR ODUCTION Minimum/Maximum Oper ating Pressures 20 psi (138 kP a) -125 psi (862 kPa) Minimum/Maximum Oper ating T emperatures 40°F (4°C) -110°F (38°C) Current Dra w & V oltage 0.5 Amperes 110 V olts Other options av ailable Ta b le 2 contains a summar y of specifications for the control v alv e and bypass v alve. Specifications T ABLE ...

  • Watts Industries WM100SM - page 5

    5 CONTR OL V AL VE FUNCTIONS This glass filled No r yl fully automatic control v al v e is designed as the primar y control center to direct and regulate all cycles of a water softener . The control v alve can be set to regenerate on demand (consumption of a predetermined amount of water) and/or as a time clock (passage of a particular number of da ...

  • Watts Industries WM100SM - page 6

    INST ALLA TION Conduct a visual check of all equipment f or any damage that ma y hav e occurred dur ing shipment. Note: If there is obvious damage to an y equipment, it should be noted on the carrier’ s Bill Of Lading. Open and inspect the contents of all closed crates, cartons, etc. and inspect for con- cealed damage. The manufacturer is not lia ...

  • Watts Industries WM100SM - page 7

    7 INST ALLA TION Figure 1: Plumbing with by pass (Standard). Figure 3: Bypass (standard). Figure 6: Figure 2: Plumbing with 3-wa y b pass. Figure 4: 3-wa y b ypass plumbing. When installing sweat copper f ollow state and f ederal codes b y using a lead free solder and flux. Use a joint comp o und to seal threaded pip e . Some home s use the cold wa ...

  • Watts Industries WM100SM - page 8

    8 INST ALLA TION STEP 4: Move brine tank next to softener and connect brine draw line to v alue . With brine tank next to the soft- ener tank connect the brine dra wline to v alv e body . Control v alves that use a regen- erant, come equipped with a 3/8" refill flow control assemb ly . To complete the regene r ant line connections o r ientate ...

  • Watts Industries WM100SM - page 9

    9 INST ALLA TION STEP 5: Connect the Drain Line If the drain line is a 5/8" fle xible poly tube, slide the n ut onto the poly tub e , then place the poly tube inse r t into the end of the poly tube and tighten the nut on to the 3/4" drain line fit- ting. The nut is only designed f or use with flexib le poly tube. Use other nuts if attachi ...

  • Watts Industries WM100SM - page 10

    10 CONTR OL PR OGRAMMING DIR/TIME CLOCK OPTIONS F or DIR Softeners, there are tw o options f or setting the Gallons Capacity . The Gallons Capacity is automatically calculated if set to A UT O . Reser ve Capacity , is automatically estimated based on water usage if A UT O is used. The other option is to set the Gallons Capacity to a specific n umbe ...

  • Watts Industries WM100SM - page 11

    CONTR OL PR OGRAMMING INST ALLER ( I ) Displa ys/Settings STEP 1 I – Press NEXT and arrow up simulta- neously f or 3 seconds. STEP 2 I – Hardness: Set the amount of hard- ness in grains of hardness as calcium carbonate per gallon using, arrow do wn or arrow up b ut- tons. The default is 20 with v alue ranges from 1 to 150 in 1 grain increments ...

  • Watts Industries WM100SM - page 12

    PR OGRAMMING (NO TE) SANITIZING THE SYSTEM 12 SET TIME OF D A Y The user can also set the time of da y . Time of day should only need to be set after e xtended pow er outages or when da y- light savings time begins or ends. If an e xtended power outage occurs, the time of da y will flash on and off which indi- cates the time of da y should be reset ...

  • Watts Industries WM100SM - page 13

    13 CONTENTS DRIVE CAP ASSEMBL Y Main Piston and Regenerant Piston The drive gears turn the main gear of the dr ive cap assemb ly , which mov es the piston. The screw-driv en, horizontally mov- ing piston stops at specific positions to direct the flow of w ater to backw ash, regenerate , rinse or refill. The PC board deter- mines the position of the ...

  • Watts Industries WM100SM - page 14

    14 CONTENTS The drain line flow control can be installed in the standard 1/4" drain line elbow , which accommodates 5/8" poly tube or 3/4" NPT drain line connections. The optional nut and poly tube inser t for the 3/4" dr ain line elbow is designed f or use with fle xible poly tube only . The 3/4" drain line elbo w can be r ...

  • Watts Industries WM100SM - page 15

    15 SYSTEM COMPONENTS DESCRIBED SYSTEM COMPONENTS DESCRIBED DRIVE ASSEMBL Y Remov e the valv e cov er to access the dr ive assemb ly . Disconnect the power source plug (b lack wire) from the PC board prior to disconnecting the motor or water meter plugs from the PC board. The motor plug connects to the two-pin jack on the left-hand side of the PC bo ...

  • Watts Industries WM100SM - page 16

    SER VICE INSTR UCTIONS board. Mo v e the spring clip loop to the r ight and hold. Rotate the motor at least a 1/4 turn in either direction before gently pulling on the wire connectors to remov e the motor . Pulling directly on the wires without rotating the motor ma y break the wires off the motor . Replace the motor if necessar y . Do not lubricat ...

  • Watts Industries WM100SM - page 17

    CONTENTS The plug and/or injector can be pried out with a small screwdriv er . The plug can be wiped clean. If the plug leaks replace the entire plug. The injector consists of a throat and a nozzle. Chemically clean the injector with vinegar or sodium bisulfite. The holes can be blown out with air . Both pieces ha v e small diameter holes that cont ...

  • Watts Industries WM100SM - page 18

    18 DRA WING AND P AR T NUMBERS BRINE T ANK AND SOFTENER T ANK FR ONT CO VER AND DRIVE ASSEMBL Y Figure 17 Figure 18 Drawing No. Order No. Description Qty . 1 KC11V317501 W100SM F ront Cov er ASY 1 2 KC12V3107-0 1 W100SM Motor 1 3 KC12F3106-01 W100SM Dr ive Br ack et 1 & Spring Clip 4 KC12V3108 W100SM PC Board 1 5 KC12V3110 W100SM Drive Gear 12x ...

  • Watts Industries WM100SM - page 19

    19 CONTENTS DRIVE CAP ASSEMBL Y , DO WNFLO W PIST ON, UPFLO W PIST ON, REGENERANT PIST ON AND SP A CER ST A CK ASSEMBL Y Drawing No. Order No. Description Qty . 1 KC12V3005 W 1 00SM Spacer Sta c k Assem b ly 1 2 KC12V3004 Drive Cap ASY 1 3 KC12V3135 O-ring 228 1 4 KC12V3011 W100SM Piston Downflo w ASY 1 5 KC12V3174 W100SM Regenerant Piston 3 6 KC12 ...

  • Watts Industries WM100SM - page 20

    20 DRA WING AND P AR T NUMBERS Drawing No. Order No. Description Qty . 1 KC12V3195-01 W100SM Refill Port Plug ASY ** 2 KC12H4615 Elbow Loc king Clip 1 3 KC12JCP-P-6 P olytube inser t 3/8 1 4 KC12JCPG-6PBLK Nut 3/8 1 5 KC12H4613 Elbow Cap 3/8 1 6 KC12V3163 O-ring 019 1 7 KC12V3165-01 W100SM RFC Retainer ASY 1 8 KC12V3182 W100SM RFC 1 *Assembly inclu ...

  • Watts Industries WM100SM - page 21

    21 DRA WING AND P AR T NUMBERS WA TER METER AND METER PLUG INST ALLA TION FITTING ASSEMBLIES Drawing No. Or der No. Description Qty . 1 KC12V3151 W100SM Nut 1” QC 1 2 KC12V3003 W100SM Meter ASY 1 3 KC12V3118-01 W100SM T urbine ASY 1 4 KC12V3105 O-r ing 215 1 5 KC12V3003-01 W100SM Meter Plug ASY 1 * Order number KC12V3003 includes KC12V3118-01 and ...

  • Watts Industries WM100SM - page 22

    Drawing No. Or der No. Description Qty . 1 KC12V3151 W100SM Nut 1” Quic k Connect 2 2 KC12V3150 W100SM Split Ring 2 3 KC12V3105 O-r ing 215 2 4 KC12V3145 W100SM Bypass 1” Rotor 2 5 KC12V3146 W100SM Bypass Cap 2 6 KC12V3147 W100SM Bypass Handle 2 7 KC12V3148 W100SM Bypass Rotor Seal Retainer 2 8 KC12V3152 O-r ing 135 2 9 KC12V3155 O-r ing 112 2 ...

  • Watts Industries WM100SM - page 23

    23 DRA WING AND P AR T NUMBERS flo w diagr am...ser vice flo w diagr am...r inse flo w diagr am...backw ash flow diag r am...fill flo w diagr am...downflo w br ine ...

  • Watts Industries WM100SM - page 24

    24 TR OUBLESHOO TING PROBLEM CA USE CORRECTION 1. Loss of Resin A. Broken distribution tube A. Replace distr ibution tube . B. Inlet/Outlet connection r e v ersed. B . Reconnect inlet/outle t connection properly . 2. Softener f ails to regene r at e . A. Elect r ical se r vice to unit has A. Assure pe r manent elect r ical se r vice been inter r up ...

  • Watts Industries WM100SM - page 25

    TR OUBLESHOO TING PROBLEM CA USE CORRECTION 8. Excessiv e water in brine tank. A. Plugged drain line flow control. A. Clean flow control. B. Plugged injector system. B. Clean injector and screen. C. F oreign mate r ial in b r ine v al v e . C . . Replace timer. D. Defectie controller. D . Replace controller. E. F oreign mater i al in b r in e E. Cl ...

  • Watts Industries WM100SM - page 26

    TR OUBLESHOO TING Tr oubleshooting Pr ogramming PROBLEM POSSIBLE CA USE SOLUTION 1. Timer does not displa y time of day a. T ransf ormer unplugged a. Connect pow er b. No elect r ic p o w er at outlet b . Repair outlet or use w o r king outle t. c. Defectiv e transformer c. Replace transf or mer d. Defectiv e PC board d. Replace PC board a. Switche ...

  • Watts Industries WM100SM - page 27

    27 CONTENTS Tr oubleshooting Pr ogramming (continued) PROBLEM POSSIBLE CA USE SOLUTION 6. Control v alv e stalled in regeneration a. Motor not operating a. Replace motor b. No electric power at outlet b . Repair outlet or use working outlet c. Defectiv e transformer c. Replace transf or mer d. Defectiv e PC board d. Replace PC board e. Broken driv ...

  • Watts Industries WM100SM - page 28

    Manuf actured by Watts W ater Quality & Conditioning Products, 13700 Highwa y 90 W ., San Antonio , TX, USA FORM: 0500-200 P/N: XOSW100SM DISTRIBUTED BY : ...

Fabbricante Watts Industries Categoria Water System

I documenti che otteniamo dal fabbricante del dispositivoWatts Industries WM100SM possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Watts Industries
- manuali per l’uso WM100SM
- schede prodotto Watts Industries
- opuscoli
- o etichette energetiche Watts Industries WM100SM
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Watts Industries WM100SM.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Watts Industries WM100SM, manuali di manutenzione, brevi manuali o manuali utente Watts Industries WM100SM. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Watts Industries WM100SM.

Manuali per l’uso simili

Manuale completo del dispositivo Watts Industries WM100SM, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Watts Industries WM100SM dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Watts Industries WM100SM.

Il manuale per l’uso completo Watts Industries, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Watts Industries WM100SM - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Watts Industries WM100SM, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Watts Industries WM100SM che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Watts Industries WM100SM - che ci dovrebbe aiutare nei primi passi durante l'uso Watts Industries WM100SM
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Watts Industries WM100SM
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Watts Industries WM100SM in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Watts Industries WM100SM?

Utilizza il modulo sottostante

Se non hai risolto il problema con Watts Industries WM100SM con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Watts Industries WM100SM è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine