    INST ALLA TION INSTRUCTIONS AND OWNER'S MANUAL SEE-THROUGH FIREPLACE MODELS: VFP36SP32EN-2 VFP36SP32EP-2 PENINSULA FIREPLACE MODELS: VFP36PP32EN-2 VFP36PP32EP-2 U.L. FILE: MH46389 W ARNING: If not installed, operated and maintained in accordance with the manufacturer's instructions, this product could expose you to substances in fuel or f ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 2

    26670-0-01 10 Page 2 T ABLE OF CONTENTS Carton Contents ...................................................................................................................... 3 Hardware Package .................................................................................................................. 3 Important Safety Information .......... ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 3

    26670-0-01 10 Page 3 CAR T ON CONTENTS Fireplace Assembly Lava Rock Package Soot W arning Sheet Installation Package Rockwool Packet Installation Instructions Serial Number T ag W arranty Card    Nailing Flange #10 x 1/2" Phillips Hex He ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 4

    26670-0-01 10 Page 4 When used without adequate combustion and ventilation air, heater may give off CARBON MONOXIDE, an odorless, poi - so no us ga s. Do not install heater until all necessary provisions are made for combustion and ventilation air . Consult the writ - ten instructions provided with the heater for information concerning combustion a ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 5

    26670-0-01 10 Page 5 Some people cannot smell well. Some people cannot smell the              can smell the odorant in propane. Smoking can decrease your ability ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 6

    26670-0-01 10 Page 6 Installation on Rugs and T ile If this appliance is installed directly on carpeting, tile or other combustible material other than wood ooring the appliance shall be installed on a metal or wood panel extending the full width and depth of the appliance. The base referred to above does not mean the re-proof base as used on ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 7

    26670-0-01 10 Page 7 Model VFP36(SP ,PP)32EN (NA T) VFP36(SP ,PP)32EP (LP) Input Maximum 38,000 38,000 Minimum 25,000 30,000 Overall Dimensions Height without standoff 37 3/4" 37 3/4" W idth 39" 39" Depth 24" 24" Gas Inlet 3/8" 3/8" ? ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 8

    26670-0-01 10 Page 8 W ater vapor is a by-product of gas combustion. An unvented room heater produces approximately one (1) ounce (30ml) of water for every 1,000 BTU's (.3KW's) of gas input per hour . Unvented room heaters are recommended as supplemental heat (a room) rather than a primary heat source (an entire house). In most supplement ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 9

    26670-0-01 10 Page 9 The space in the above example is a conned space because the actual BTU/Hr used is more than the maximum BTU/HR the space can support. Y ou must provide additional fresh air . Y our options are as follows: A. Rework worksheet, adding the space of an adjoining room. If the extra space provides an unconned space, remove doo ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 10

    26670-0-01 10 Page 10 Check all local codes for requirements, especially for the size and type of gas supply line required. Note: Never use plastic pipe. Check to conrm whether your local codes allow copper tubing or galvanized. Note: Since some municipalities have additional local codes, it is always best to consult your local authority and ins ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 11

    26670-0-01 10 Page 1 1 CLEARANCES Figure 4a - See Through Fir eplace Clearances 36” MIN. 42” MIN. (CEILING TO TO P O F H OOD) 1 3/4 ” M IN. PERPENDICULAR COMBUSTIBLE SIDEWALL 36” MIN. 42” MIN. (CEILING TO TO P O F H OOD) 1 3/4 ” M IN. PERPENDICULAR COMBUSTIBLE SIDEWALL Figure 4b - Peninsula Fir eplace Clearances Sidewall Clearances: The ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 12

    26670-0-01 10 Page 12  Figure 6a - Mantel Clearances with Standard Hood Figure 6b - Mantel Clearances with Optional Extended Hood MANTEL ST ANDARD HOOD 17 ½” 10” 12” MAX 42” MIN. (CEILING TO TO PO F HOOD) 4 ½ ” MIN. FIREBOX F ACE 84” MIN. (CEILING TO FLOOR) CEILING COMBUSTIBLES ALL ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 13

    26670-0-01 10 Page 13 Fireplace Framing Framing can be built before or after the replace is set in place. Framing should be constructed to accommodate wall covering and replace facing material. The replace framing should be constructed of 2 x 4 lumber or heavier . The framing headers may rest on the top of the replace standof fs. Refer ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 14

    26670-0-01 10 Page 14  Fireplace Dimensions    VFP36SP VFP36PP A 34 3/4" 34 3/4" B 39" 39" C 24" 24" D 22" 22" E 36" 36" F 34 1/4&qu ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 15

    26670-0-01 10 Page 15 Locating Fireplace Place replace in framed opening. Attach the framing brackets to the replace and secure to framing. Different hole locations can be used for nishing materials with thicknesses of 3/8", 1/2" and 3/4". Secure the brackets with screws provided using two (2) per framing bracket. ? ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 16

    26670-0-01 10 Page 16 Extended Hoods If your non-combustible facing material is over 1" in thickness and will be used to nish this replace, extended hoods are available that will extend out 2" farther into the room. Extended hoods are not available for the peninsula open ends. Contact your local dealer for details. Extended Hoods VB ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 17

    26670-0-01 10 Page 17 The replace is designed to accept a gas line for connection to the gas valve. Have the line installed by a qualied service person in accordance with all building codes. Consult local building codes to properly size the gas supply line leading to the connection of the valve. The state of Massachusetts requires that a e ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 18

    26670-0-01 10 Page 18 Place ment of the glowing embers (rockwoo l) is very indiv idual and light coverage of the areas indicated will provide your best effects. W e recommend separation of the rockwool by hand and to make your coverage as light and uffy as possible. Place just enough embers on the burner to obtain the glow and a gold yellow a ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 19

    26670-0-01 10 Page 19 Before you begin: Do not handle the logs with your bare hands! Always wear gloves to prevent skin irritation. After handling logs, wash your hands gently with soap and water . All Logs The positioning of the logs is critical to the safe and clean opera- tion of this heater . Sooting and other problems may result if the logs ar ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 20

    26670-0-01 10 Page 20 1. ST OP! Read the safety information label. 2. Open bottom louver assembly . 3. Set REMOTE/OFF/ON switch to "OFF ." 4. T urn off all electric power to the appliance (if applicable). 5. Push in gas control knob slightly and turn clockwise to "OFF ." NOTE: Knob cannot be turned from "PILOT" to &quo ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 21

    26670-0-01 10 Page 21 Check the following items during installation prior to lighting the multisided burner: • Check all carryover ports for blockage from the ceramic media o If there is blockage, use a small pointed tool to move the ceramic media away from the carryover port. • Check air shutter for correct setting. o NA T gas – Air shutter ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 22

    26670-0-01 10 Page 22 Figure 16 show a correct pilot ame pattern. The correct ame will be blue and will extend beyond the thermocouple. The ame will surround the thermocouple just below the tip. A slight yellow ame may occur where the pilot ame and main burner ame meet. Figure 17 show an incorrect pilot ame pattern. The incorre ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 23

    26670-0-01 10 Page 23 Label all wires prior to disconnection when servicing controls. W iring errors can cause improper and dangerous operation. V erify proper operation after servicing. Milli volt thermopi le is self powere d, gas valve does not requir e 1 10 volts. Maximum length of 20 feet of 16 A WG two (2) conductor wires should be used with a ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 24

    26670-0-01 10 Page 24                ? ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 25

    26670-0-01 10 Page 25       In order to install both the optional Blower and Accent Light ac- cessories, it will be necessary to install the junction box so that the D ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 26

    26670-0-01 10 Page 26 Attention: Install blower assembly before connecting gas in- let supply line. Wiring The appliance, when installed, must be electrically grounded in accordance with local codes or , in the absence of local codes, with the National Electrical Code, ANSI/NFP A 70 , if an exter- nal electrical source is utilized. This appliance i ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 27

    26670-0-01 10 Page 27 4. Insert blower assembly into interior , bottom of rebox. Note: On peninsula models, the blower must be installed at the end which has the brick panel installed. Position blower assembly so that you align the notch on back of blower as- sembly with the center screw on side/end panel, then push the blower assembly against ? ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 28

    26670-0-01 10 Page 28 Wiring The appliance, when installed, must be electrically grounded in accor dance with loca l co des o r , i n th e abs ence of lo cal c odes, with the National Electrical Code, ANSI/NFP A 70 , if an external electrical source is utilized. This appliance is equipped with a thr ee-pr ong [gro unding] plug for your prot ection ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 29

    26670-0-01 10 Page 29 MAINTENANCE Keep the control compartment, logs and burner area surround- ing the logs clean by vacuuming or brushing area at least twice a year . THE LOGS CAN GET VER Y HOT - HANDLE ONL Y WHEN COOL. Always turn off gas to the pilot before cleaning. For relighting, refer to the lighting instructions plate located in the lower c ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 30

    26670-0-01 10 Page 30 USE ONL Y MANUF ACTURER'S REPLACEMENT P AR TS. USE OF ANY OTHER P AR TS COULD CAUSE INJUR Y OR DEA TH. NOTE: SEE LOG INSTRUCTION MANUAL FOR DET AILS ON LOGS AND EMBERS A TTENTION: When ordering parts, it is very important that part number and description of part coincide. P AR TS LIST INDEX NUMBER P ART NUMBER DESCRIPTION ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 31

    26670-0-01 10 Page 31 Parts can be ordered only through your service person or dealer . For best results, the service person or dealer should order parts through the distributor . Parts can be shipped directly to the service person/dealer . All parts listed in the Parts List have a Part Number . When ordering parts, rst obtain the Model Number f ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 32

    26670-0-01 10 Page 32 SEE-THROUGH FIREPLACE P AR TS VIEW 1 4 6 5 16 8 9 12 14 4 5 6 8 12 14 9 7 3 2 24 25 20 17 18 31 41 40 21 23 29 33 30 19 22 34 28 26 Nat Gas 36 37 35 27 42 32 38 39 24 25 43 44 45 46 47 44 21 NA T. BURNER ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 33

    26670-0-01 10 Page 33 PENINSULA FIREPLACE P AR TS VIEW 1 4 5 6 8 9 11 10 12 13 14 15 16 8 12 14 9 7 3 2 24 25 20 17 18 31 41 40 21 23 29 33 30 19 22 34 28 26 Nat Gas 36 37 35 27 42 32 38 39 24 LP BURNER 25 43 44 45 46 47 44 21 NA T. BURNER ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 34

    26670-0-01 10 Page 34 Accessory Description Model Numbers  1 2 Designed to provide forced air ow . FBB5   W all mounted variable speed control for use with FBB5 blower SCV -1  Standard 3-Piece Frame Kits Black, Brass, ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 35

    26670-0-01 10 Page 35 Accessory Description Model Numbers  Optional light kit that installs in top of rebox to enhance logset. Operates with a Rheostat control to vary brightness of light for desired effect. LK2  Extended hoods that extend out 2&qu ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 36

    26670-0-01 10 Page 36 SER VICE NOTES ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 37

    26670-0-01 10 Page 37 Web Site: www .empirecomfort.com Premium V ent-Free Fireplaces SEE-THROUGH FIREPLACE MODELS: VFP36SP32EN-2 VFP36SP32EP-2 PENINSULA FIREPLACE MODELS: VFP36PP32EN-2 VFP36PP32EP-2 Empire Comfort Systems 918 Freeburg Avenue Belleville, Illinois 62220-2623 GAS-FIRED 36-inch Fireplace accommodates the following Log Set: Refractory L ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 38

    26670-0-01 10 Page 38 Web Site: www .empirecomfort.com Premium V ent-Free Fireplaces SEE-THROUGH FIREPLACE MODELS: PENINSULA FIREPLACE MODELS: VFP36SP32EN-2 VFP36PP32EN-2 VFP36SP32EP-2 VFP36PP32EP-2 Empire Comfort Systems 918 Freeburg Avenue Belleville, Illinois 62220-2623 Mantel Clearances with Standard Hood MANTEL ST ANDARD HOOD 17 ½” 10” 12 ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 39

    26670-0-01 10 Page 39 Premium V ent-Free Fireplace Framing Dimensions (inches) "A" "B" "C"* Model Framing Height Framing Width Framing Depth VFP36SP 41 1/2" 40" 23"* VFP36PP 41 1/2" 39"** 23"* Attention: Add height of base to "A" Dimension when elevating re - place if installi ...

  • Empire Comfort Systems VFP36SP32EN-2 - page 40

    26670-0-01 10 Page 40 EMPIRE EMPIRE C o mfo r t Systems Empire Comfort Systems Inc. 918 Freeburg A ve. Belleville, IL 62220 If you have a general question about our products, please e-mail us at info@empirecomfort.com. If you have a service or repair question, please contact your dealer . www .empirecomfort.com ...

Fabbricante Empire Comfort Systems Categoria Indoor Fireplace

I documenti che otteniamo dal fabbricante del dispositivoEmpire Comfort Systems VFP36SP32EN-2 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Empire Comfort Systems
- manuali per l’uso VFP36SP32EN-2
- schede prodotto Empire Comfort Systems
- opuscoli
- o etichette energetiche Empire Comfort Systems VFP36SP32EN-2
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Empire Comfort Systems VFP36SP32EN-2.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Empire Comfort Systems VFP36SP32EN-2, manuali di manutenzione, brevi manuali o manuali utente Empire Comfort Systems VFP36SP32EN-2. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Empire Comfort Systems VFP36SP32EN-2.

Manuale completo del dispositivo Empire Comfort Systems VFP36SP32EN-2, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Empire Comfort Systems VFP36SP32EN-2 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Empire Comfort Systems VFP36SP32EN-2.

Il manuale per l’uso completo Empire Comfort Systems, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Empire Comfort Systems VFP36SP32EN-2 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Empire Comfort Systems VFP36SP32EN-2, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Empire Comfort Systems VFP36SP32EN-2 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Empire Comfort Systems VFP36SP32EN-2 - che ci dovrebbe aiutare nei primi passi durante l'uso Empire Comfort Systems VFP36SP32EN-2
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Empire Comfort Systems VFP36SP32EN-2
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Empire Comfort Systems VFP36SP32EN-2 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Empire Comfort Systems VFP36SP32EN-2?

Utilizza il modulo sottostante

Se non hai risolto il problema con Empire Comfort Systems VFP36SP32EN-2 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Empire Comfort Systems VFP36SP32EN-2 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)