Manuale per l’uso Faria Instruments GW0016

14 pagine 1.16 mb
Scarica

Vai alla pagina of 14

Summary
  • Faria Instruments GW0016 - page 1

    Serial Bus for Navy Gateway GW0016 • Visual/Audible Alert messages • Easy Installation • W aterproof Connections • Easy to read Digital displays • Multiple Interfaces IS0210 rev . A ecr#4821 Aug. 2004 Owners’ s Manual M ...

  • Faria Instruments GW0016 - page 2

    Table of Contents Quick Reference page 2 turn system on/off page 2 turn on instrument lighting page 2 change lighting intensity page 2 disable audible alarm in Normal Mode page 2 change LCD display page 2 reset Trip Fuel Consumed page 2 Specifications page 3 Turning the Gateway system ON/OFF page 3 System description page 3 Installation page 3 Sys ...

  • Faria Instruments GW0016 - page 3

    Navy Gateway (GW0016) System Manual The system consists of: • One Gateway box to interface with engine and external senders and sensors. • One 4” Tachometer with Fuel Monitor • Various 2” instruments, including but not limited to • Voltmeter • Oil Pressure gauge • Fuel gauge • Engine Temperature gauge • Transmission Temperature ...

  • Faria Instruments GW0016 - page 4

    Gateway System Specifications: Operation voltage: +12 V DC or +24 V DC +12 V DC (10 V DC (Min.) to 16 V DC (max.)) +24 V DC (20 V DC (Min.) to 32 V DC (max.)) Maximum Current with maximum backlight: < 1500 mA @ 12 V DC Minimum Current at switch off status: < 10 mA @ 12 V Operational temperature: -40˚ F to 185˚ F (-40˚ C to 85˚ C) Storage ...

  • Faria Instruments GW0016 - page 5

    Several alarm conditions may also be displayed in the LCD display when needed: 1 Low fuel 2 Low oil pressure 3 Low voltage Alarm messages will be displayed on the tachometer LCD display. Messages will also include a flashing red light. All messages will be displayed until either the problem is corrected or the operator manually cancels the warning ...

  • Faria Instruments GW0016 - page 6

    b) Imperial gallons. Display will show c) Liters. Display will show Leaving the display in one of the items above while the “Mode” button is pressed and held for more than one second will save the selected units. Trip Fuel Consumed Displays fuel consumed since last reset. This function can be reset to zero before a trip to show fuel consumed du ...

  • Faria Instruments GW0016 - page 7

    Holding the “Mode” button for more than one second while the display is showing “ADJXXX.X” will set the amount in the display “XXX.X” into the Trip Fuel Consumed and return to the Trip Fuel Consumed function. The difference between the original and the new amount of fuel will be used to change the calibration of the instant and accumula ...

  • Faria Instruments GW0016 - page 8

    When the “Fuel Remaining” reaches this amount, the “Low Fuel” alarm will sound and a warning LED will flash in the display. The display will automatically go into “set” mode to allow the operator to reset the alarm value to a lower value to turn off the alarm if desired. If the option is set to zero, the “Low Fuel” alarm will be di ...

  • Faria Instruments GW0016 - page 9

    LCD Alarm Condition Displays. Alarm messages will be displayed on the Tachometer LCD display. All messages will be displayed until the problem is corrected, or the operator cancels the warning message. Severe co nditions includes a flashing red light. Low Battery V oltage (Flashing Red Light) Low Oil Pressur e (Flashing Red Light) Low Fuel Level (F ...

  • Faria Instruments GW0016 - page 10

    Page 9 Faria ® Serial Bus Installation and Wiring Guide The system consists of: • One Gateway box to interface with the engine and external senders and sensors. • One 4” Tachometer with Fuel Monitor • Various 2” instruments, including but not limited to • Voltmeter • Oil Pressure gauge • Engine Temperature gauge • Fuel Level gaug ...

  • Faria Instruments GW0016 - page 11

    Page 10 T able1 Connector Contacts Pin Pin Function Wir e Color *5 amp Fuse Recommended P1 2 Not used P2 4 1 Battery Positive (always on)* Red 2 Ground 3 Switched Power from Ignition Purple switch circuit 4 Ground Black P3 4 All Faria® Bus Data and N/A Instrument Power P4 2 Not Used (PJ0015) P5 3 Not Used (PJ0016) P6 3 Not Used P7 3 Not Used P8 PP ...

  • Faria Instruments GW0016 - page 12

    Page 11 Faria Serial Bus Gateway T ypical Power Connections T ypical Instrument Connections P15 P13 P14 P12 P1 1 P7 P8 P10 P6 P5 P4 P1 P3 P15 P13 P14 P12 P1 1 P7 P8 P10 P6 P5 P4 P1 P3 P2 Note: T o help reduce moisture in the gauges be sure to install plug PJ0018 in all open connectors. PJ0018 POS NEG Battery - + P2 1 2 4 3 Black Purple Red Figure 2 ...

  • Faria Instruments GW0016 - page 13

    Page 12 P15 P13 P12 P7 P8 P10 P6 P5 P4 P1 P3 P2 White White Dk. Blue Nav . Light Switch Instrument Backlight Control P 1 1 6 5 4 3 2 1 7 8 9 10 1 1 12 P 12 6 5 4 3 2 1 7 8 9 10 1 1 12 Faria Serial Bus Gateway Miscellaneous Connections Pink Lt. Blue Oil Pressur e Sender Fuel T a nk Sender P 14 1 2 3 6 5 4 T rans. Sender Engine T emp. Sender T achome ...

  • Faria Instruments GW0016 - page 14

    Copyright 2004 by the Thomas G. Faria Corporation, Uncasville CT No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without the prior written permission of the company . Faria ® is the trademark of the Thomas G. Faria Corporation ...

Fabbricante Faria Instruments Categoria Switch

I documenti che otteniamo dal fabbricante del dispositivoFaria Instruments GW0016 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Faria Instruments
- manuali per l’uso GW0016
- schede prodotto Faria Instruments
- opuscoli
- o etichette energetiche Faria Instruments GW0016
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Faria Instruments GW0016.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Faria Instruments GW0016, manuali di manutenzione, brevi manuali o manuali utente Faria Instruments GW0016. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Faria Instruments GW0016.

Manuale completo del dispositivo Faria Instruments GW0016, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Faria Instruments GW0016 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Faria Instruments GW0016.

Il manuale per l’uso completo Faria Instruments, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Faria Instruments GW0016 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Faria Instruments GW0016, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Faria Instruments GW0016 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Faria Instruments GW0016 - che ci dovrebbe aiutare nei primi passi durante l'uso Faria Instruments GW0016
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Faria Instruments GW0016
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Faria Instruments GW0016 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Faria Instruments GW0016?

Utilizza il modulo sottostante

Se non hai risolto il problema con Faria Instruments GW0016 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Faria Instruments GW0016 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine