Manuale per l’uso GE 8500 Series

28 pagine 2.07 mb
Scarica

Vai alla pagina of 28

Summary
  • GE 8500 Series - page 1

    TINSEA612JBRZ 49-7639 01-10 GE Air Co n d i t i o n ers Safety Instructions ........... 2 Operating Instructions Controls—Dip Switches ........ . 3–5 Controls—Terminal Connections ................... 6, 7 On/Off Switch .................... 8 Ventilation Control ............... 8 Care and Cleaning Air Filters ........................ 9 Base Pa ...

  • GE 8500 Series - page 2

    Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions IMPORTANT SAFETY INFORMATION. READ ALL INSTRUCTIONS BEFORE USING. WARNING! Risk of electric shock. Can cause injury or death. For your safety, the information in this manual must be followed to minimize the risk of fir e, electric shock or personal in ...

  • GE 8500 Series - page 3

    Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support 3 Controls–dip switches. GEAppliances.com The dip switch controls are located behind the front case panel, through an opening on the front of the unit. To access the dip switches, remove the front case panel by removing the filter, taking out the fo ...

  • GE 8500 Series - page 4

    Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions 4 Controls–dip switches. Freeze Sentinel (Requires room air sensor kit–RAVRMS) When this switch is enabled (UP), it turns OFF the freeze sentinel protection feature. With the switch disabled (DOWN), the freeze sentinel is activated which automatic ...

  • GE 8500 Series - page 5

    5 Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support GEAppliances.com Temperature Limiting (Requires room air sensor kit–RAVRMS) Temperature limiting can reduce energy costs by limiting the lowest temperature that can be set for cooling and the highest temperature that can be set for heating. Temper ...

  • GE 8500 Series - page 6

    6 Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions Controls—terminal connections. Controls–Terminal Connections The terminal connections are located behind the front case panel through an opening on the front of the unit. To access the terminal connections, remove the front panel by removing the ...

  • GE 8500 Series - page 7

    Remote Thermostat The unit will be controlled by a remote thermostat. IMPORTANT: The Zoneline thermostat connections provide 24V AC only. If using a digital/electronic wall thermostat, you must set it to the 24V AC setting. See the Installation Instructions for the wall thermostat. NOTICE: Damage to a wall thermostat or to the Zoneline electronics ...

  • GE 8500 Series - page 8

    The ventilation control lever is located on the left side of the Zoneline unit, behind the front case panel. To access the ventilation control lever, remove the front panel by removing the filter, taking out the four front screws, the upper two screws from the top of the panel and the shipping screws on each side, if present. (Discard the four side ...

  • GE 8500 Series - page 9

    Indoor/Outdoor Coils The exhaust coils on the Zoneline should be checked regularly. If they are clogged with dirt or soot, they may be professionally steam cleaned by your GE service center. You will need to remove the unit from the case to inspect the coils because the dirt build-up occurs on the exhaust side. 9 Safety Instructions Operating Instr ...

  • GE 8500 Series - page 10

    BEFORE YOU BEGIN Installation Zoneline Air Instructions Conditioners Read these instructions completely and carefully. • IMPORTANT – Save these instructions for local inspector’s use. • IMPORTANT – Observe all governing codes and ordinances. • Note to Installer – Be sure to leave these instructions with the owner. • Note to Owner ? ...

  • GE 8500 Series - page 11

    11 Installation Instructions ELECTRICAL REQUIREMENTS 230/208 VOLT ELECTRICAL SUPPLY Tandem 15 Amp 230/208 volt receptacle configuration Perpendicular 20 Amp Large Tandem 30 Amp • Use ONLY the wiring size recommended for single outlet branch circuit. • Proper current protection is the responsibility of the owner. A power supply kit must be used ...

  • GE 8500 Series - page 12

    REMOVE JUNCTION BOX COVER • Remove the junction box cover by taking out the front two screws. 1 Junction box Installation Instructions 12 DIRECT CONNECT APPLICATIONS FOR 265 VOLT DIRECT CONNECT APPLICATIONS ONLY I MPORTANT: Connection of a 265V AC product to a branch circuit MUST be done by direct connection in accordance with the National Electr ...

  • GE 8500 Series - page 13

    13 Installation Instructions DIRECT CONNECT APPLICATIONS MAKE WIRE LEAD CONNECTIONS INSIDE THE JUNCTION BOX 1. Make all wire connections by using appropriate UL-listed electrical connectors and techniques. 2. Select the applicable wiring situation and follow the instructions accordingly: 3. Be sure that all wire leads are inside the junction box an ...

  • GE 8500 Series - page 14

    Installation Instructions 14 ZONELINE COMPONENTS Case Zoneline unit Front Case Panel REQUIRED ACCESSORIES (Check the “Essential Elements” label on the unit.) Architectural Louver RAVAL1 Wall Plenum RAVWP6 - 6"D x 19 3 ⁄ 4 ”W x 32”H RAVWP8 - 8”D x 19 3 ⁄ 4 ”W x 32”H RAVWP12 - 12”D x 19 3 ⁄ 4 ”W x 32”H RAVWP15 - 15”D ...

  • GE 8500 Series - page 15

    Installation Instructions 15 TYPICAL UTILITY CLOSET AND DIMENSIONS (FOR REFERENCE ONLY) Side View Top View Architectural Louver 10 ” duct Door/access panel 5” min. 5” min. Unit front 3” min. 14” min. – Required only if optional Hydronic Heating Kit (RAVHW1, RAVHW2, RAVHW3) is to be installed. Clearance for installation should be taken i ...

  • GE 8500 Series - page 16

    Installation Instructions 16 UTILITY CLOSET CONNECTION LOCATIONS IMPORTANT: Plan and locate plenum, wall plug, drains and thermostat carefully to avoid interference. Hard-to-reach locations will make installation and service difficult! Reference Dimensions A Thermostat cable: 9 1 ⁄ 2 ” long B Power cord: 60” long C Case width and depth: 23 1 ...

  • GE 8500 Series - page 17

    Installation Instructions 17 RETURN AIR GRILLE INSTALLATION OPTIONS The room return air grille may be installed toward the front or either side of the unit. Improper return air arrangements will cause performance problems. There are three indoor return air grille installation options. Choose the option that best suits your installation requirements ...

  • GE 8500 Series - page 18

    BUILD AND INSTALL THE ZONELINE BASE PLATFORM 1. Construct a 23 1 ⁄ 4 ” min. x 23 1 ⁄ 4 ” min. square platform with legs to raise the platform a minimum of 8”. NOTE: The platform must have a load-bearing capacity of 175 lbs. minimum. 1 Installation Instructions 18 WALL PLENUM AND ARCHITECTURAL LOUVER INSTALLATION • Install the appropriat ...

  • GE 8500 Series - page 19

    INSTALL THE DRAIN(S) An external or an internal drain must be attached to the primary drain connector. A secondary drain is supplied if required by state and local codes. Refer to the local codes for proper installation of the drains. If the secondary drain is not used, seal its drain port with a 3/4” MNPT plug. External Drain Attach a 90° PVC e ...

  • GE 8500 Series - page 20

    INSTALL AND CONNECT THE CASE 1. Remove the front case panel and pull the unit out of the case. Place the empty case onto the platform in the closet with the outdoor side facing the wall plenum opening. Align the case with plenum opening and attach with six field-supplied sheet metal screws (corrosion-resistant screws recommended). 2. Adjust all fou ...

  • GE 8500 Series - page 21

    Top duct Clamp Case top duct adjusting screws MAKE UNIT ELECTRICAL CONNECTIONS 1. Connect the thermostat wires to the unit and set the dip switches to the appropriate settings. NOTE: See the Controls–Terminal Connections and Controls–Dip Switches sections of this manual and the manual with the separate thermostat for proper connections and sett ...

  • GE 8500 Series - page 22

    Installation Instructions SERVICING WARNING: Risk of Electric Shock, can cause injury or death. Before servicing, switch power off at the service panel and lock the area to prevent power from being switched on accidentally. When the area cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. NOTE: We stro ...

  • GE 8500 Series - page 23

    Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support Before You Call For Service… GEAppliances.com Troubleshooting Tips Problem Possible Causes What To Do Zoneline does The unit is unplugged. • Make sure the Zoneline plug is pushed completely not start into the outlet. The fuse is blown/circuit • ...

  • GE 8500 Series - page 24

    24 Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions Normal Operating Sounds You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency. You may hear relays ...

  • GE 8500 Series - page 25

    Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support Notes. GEAppliances.com 25 ...

  • GE 8500 Series - page 26

    Notes. 26 Consumer Support Troubleshooting Tips Care and Cleaning Operating Instructions Safety Instructions ...

  • GE 8500 Series - page 27

    Safety Instructions Operating Instructions Care and Cleaning Troubleshooting Tips Consumer Support 27 Vertical Zoneline Warranty. n Service trips to your site to teach you how to use the product. n Improper installation, delivery or maintenance. n If you have an installation problem, or if the air conditioner is of improper cooling or heating capac ...

  • GE 8500 Series - page 28

    Consumer Support. GE Appliances Website GEAppliances.com Have a question or need assistance with your appliance? Try the GE Appliances Website 24 hours a day, any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts or even schedule service on-line. Schedule Service GEAppliances.com Expert ...

Fabbricante GE Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoGE 8500 Series possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici GE
- manuali per l’uso 8500 Series
- schede prodotto GE
- opuscoli
- o etichette energetiche GE 8500 Series
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso GE 8500 Series.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione GE 8500 Series, manuali di manutenzione, brevi manuali o manuali utente GE 8500 Series. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto GE 8500 Series.

Manuali per l’uso simili

Manuale completo del dispositivo GE 8500 Series, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare GE 8500 Series dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti GE 8500 Series.

Il manuale per l’uso completo GE, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale GE 8500 Series - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice GE 8500 Series, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per GE 8500 Series che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo GE 8500 Series - che ci dovrebbe aiutare nei primi passi durante l'uso GE 8500 Series
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del GE 8500 Series
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio GE 8500 Series in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su GE 8500 Series?

Utilizza il modulo sottostante

Se non hai risolto il problema con GE 8500 Series con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con GE 8500 Series è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)