Manuale per l’uso Desa FAS-30BB

24 pagine 0.48 mb
Scarica

Vai alla pagina of 24

Summary
  • Desa FAS-30BB - page 1

    BLUE FLAME VENT -FREE NA TURAL GAS HEA TER OWNER’S OPERA TION AND INST ALLA TION MANUAL Save this manual for future reference. F A-20BB F AS-20BB F A-30BB F AS-30BB FGH-30NGB 20,000 and 30,000 Btu/Hr Models WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, ...

  • Desa FAS-30BB - page 2

    2 105568 BLUE FLAME NA TURAL GAS HEA TER Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the heater may not be working properly. Get fresh air at once! Have heater serviced. Some people are more affected by carbon monoxide than others. These include ...

  • Desa FAS-30BB - page 3

    3 105568 OWNER’S MANUAL PRODUCT IDENTIFICA TION LOCAL CODES Install and use heater with care. Follow all local codes. In the absence of local codes, use the latest edition of National Fuel Gas Code ANS Z223.1 , also known as NFPA 54*. *Available from: American National Standards Institute, Inc. 1430 Broadway New York, NY 10018 National Fire Prote ...

  • Desa FAS-30BB - page 4

    4 105568 BLUE FLAME NA TURAL GAS HEA TER AIR FOR COMBUSTION AND VENTILA TION Today’s homes are built more energy effi- cient than ever. New materials, increased insulation, and new construction methods help reduce heat loss in homes. Home owners weather strip and caulk around windows and doors to keep the cold air out and the warm air in. During ...

  • Desa FAS-30BB - page 5

    5 105568 OWNER’S MANUAL AIR FOR COMBUSTION AND VENTILA TION Continued DETERMINING FRESH-AIR FLOW FOR HEATER LOCATION Determining if You Have a Confined or Unconfined Space Use this worksheet to determine if you have a confined or unconfined space. Space: Includes the room in which you will install heater plus any adjoining rooms with doorless pas ...

  • Desa FAS-30BB - page 6

    6 105568 BLUE FLAME NA TURAL GAS HEA TER Figure 3 - Ventilation Air from Outdoors Outlet Air Ventilated Attic Outlet Air Inlet Air Inlet Air Ventilated Crawl Space To Crawl Space To Attic Ventilation Air From Outdoors Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ...

  • Desa FAS-30BB - page 7

    7 105568 OWNER’S MANUAL 36" 2" FLOOR CEILING Minimum Minimum to Top of Carpeting, Tile, or Other Combustible Material 6" Minimum From Sides of Heater Left Side Right Side INST ALLA TION Continued CHECK GAS TYPE Use only natural gas. If your gas supply is not natural, do not install heater. Call dealer where you bought heater for pr ...

  • Desa FAS-30BB - page 8

    8 105568 BLUE FLAME NA TURAL GAS HEA TER Models FA-30BB, FAS-30BB, and FGH-30NGB Models FA-20BB and FAS-20BB Figure 8 - Mounting Bracket Clearances WARNING: Maintain minimum clearances shown in Figure 7. If you can, provide greater clear- ances from floor and joining wall. Figure 7 - Removing Front Panel Of Heater Methods For Attaching Mounting Bra ...

  • Desa FAS-30BB - page 9

    9 105568 OWNER’S MANUAL Figure 9 - Folding Anchor INST ALLA TION Continued Attaching Mounting Bracket To Wall Note: Wall anchors, mounting screws, and spacers are in hardware package. The hard- ware package is provided with heater. Attaching To Wall Stud Method For attaching mounting bracket to wall studs 1. Drill holes at marked locations using ...

  • Desa FAS-30BB - page 10

    10 105568 BLUE FLAME NA TURAL GAS HEA TER CONNECTING TO GAS SUPPLY WARNING: A qualified service person must connect heater to gas supply. Follow all local codes. WARNING: Never connect heater to private (non-utility) gas well. This gas is commonly known as wellhead gas. Typical Inlet Pipe Diameters FA-20BB, 3/8" or greater FAS-20BB FA-30BB, 1/ ...

  • Desa FAS-30BB - page 11

    11 105568 OWNER’S MANUAL O POS P O Figure 14 - Equipment Shutoff Valve Figure 15 - Checking Gas Joints Equipment Shutoff Valve Closed WARNING: Test all gas pip- ing and connections for leaks after installation or servicing. Correct all leaks at once. WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to ...

  • Desa FAS-30BB - page 12

    12 105568 BLUE FLAME NA TURAL GAS HEA TER TO TURN OFF GAS TO APPLIANCE 1. Remove front panel (see Figur e 7, page 8). 2. Follow steps 1 thr ough 5 under Light- ing Instructions . 3. With contr ol knob pr essed in, str ike match. Hold match to pilot until pi- lot lights. 4. Keep contr ol knob pressed in f or 30 seconds after lighting pilot. After 30 ...

  • Desa FAS-30BB - page 13

    13 105568 OWNER’S MANUAL LIGHTING INSTRUCTIONS NON-THERMOSTAT MODELS FA-20BB, FA-30BB AND FGH-30NGB A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, f ollow these instructions exactly . B . BEFORE LIGHTING smell all around the appliance ar ea for g as. Be sure to smell next to the floor because some gas is hea ...

  • Desa FAS-30BB - page 14

    14 105568 BLUE FLAME NA TURAL GAS HEA TER Figure 21 - Incorrect Pilot Flame Pattern Thermocouple Pilot Burner INSPECTING BURNER Check pilot flame pattern and burner flame pattern often. PILOT FLAME PATTERN Figure 20 shows a correct pilot flame pattern. Figure 21 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the ...

  • Desa FAS-30BB - page 15

    15 105568 OWNER’S MANUAL TROUBLESHOOTING Note: All troubleshooting items are listed in order of operation. WARNING: Turn off and un- plug heater and let cool before servicing. Only a qualified ser- vice person should service and repair heater. CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit ...

  • Desa FAS-30BB - page 16

    16 105568 BLUE FLAME NA TURAL GAS HEA TER OBSERVED PROBLEM Burner does not light after ODS/pilot is lit Delayed ignition of burner Burner backfiring during combustion Yellow flame during burner combustion Slight smoke or odor during initial operation Heater produces a whistling noise when burner is lit White powder residue forming within de- flecto ...

  • Desa FAS-30BB - page 17

    17 105568 OWNER’S MANUAL WARNING: If you smell gas • Shut off gas supply. • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • If you cannot reach your gas supplier, cal ...

  • Desa FAS-30BB - page 18

    18 105568 BLUE FLAME NA TURAL GAS HEA TER Baltimore Electric 1348 Dixwell Avenue Hamden, CT 06514-0322 1-800-397-7553 203-248-7553 Parts Department Portable Heater Parts 342 N. County Rd. 400 East Valparaiso, IN 46383-9704 All States 219-462-7441 1-800-362-6951 sales@portableheaterparts.com techservice@portableheaterparts.com FBD 1349 Adams Street ...

  • Desa FAS-30BB - page 19

    19 105568 OWNER’S MANUAL FAN KITS - UH1000FB, AND UHS1000FB For all models. Provides better heat distri- bution. Makes heater more efficient. Com- plete installation and operating instructions included. Manually-controlled - UH1000FB. Includes ON/OFF switch. Thermostatically-controlled - UHS1000FB. Includes three settings: ON/OFF/AUTO. ACCESSORIE ...

  • Desa FAS-30BB - page 20

    20 105568 BLUE FLAME NA TURAL GAS HEA TER ILLUSTRA TED PA R T S BREAKDOWN THERMOSTAT MODELS FAS-20BB FAS-30BB 7 7 28 2 28 27 22 26 23 19 17 24 25 12 26 21 20 18 9 8 18 16 10 16 13 1 14 14 15 7 29 11 3 4 5 7 6 7 7 24-1 24-2 ODS/Pilot Assembly ...

  • Desa FAS-30BB - page 21

    21 105568 OWNER’S MANUAL P ARTS LIST THERMOSTAT MODELS FAS-20BB FAS-30BB This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. KEY PART NUMBER FOR NO. FAS-20BB FAS-30BB DESCRIPTION QTY. 1 L98409-10 L98409-09 Cabinet Assembly 1 2 L98006-02 L9 ...

  • Desa FAS-30BB - page 22

    22 105568 BLUE FLAME NA TURAL GAS HEA TER ILLUSTRA TED PA R T S BREAKDOWN NON-THERMOSTAT MODELS FA-20BB, FA-30BB, AND FGH-30NGB 8 8 32 2 32 31 26 30 27 23 17 28 29 10 30 25 24 22 16 13 1 17 22 20 9 16 18 19 14 14 15 8 12 11 33 3 7 4 5 8 6 8 8 21 28-1 28-2 ODS/Pilot Assembly ...

  • Desa FAS-30BB - page 23

    23 105568 OWNER’S MANUAL P ARTS LIST NON-THERMOSTAT MODELS FA-20BB, FA-30BB, AND FGH-30NGB This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 19 of this manual. KEY PART NUMBER FOR NO. FA-20BB FA-30BB FGH-30NGB DESCRIPTION QTY. 1 L98409-08 L98409-07 L98409- ...

  • Desa FAS-30BB - page 24

    KEEP THIS WARRANTY Model Serial No. Date Purchased Always specify model and serial numbers when communicating with the factory. We reserve the right to amend these specifications at any time without notice. The only warranty applicable is our standard written warranty. We make no other warranty, expressed or implied. W ARRANTY INFORMA TION 105568-0 ...

Fabbricante Desa Categoria Electric Heater

I documenti che otteniamo dal fabbricante del dispositivoDesa FAS-30BB possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Desa
- manuali per l’uso FAS-30BB
- schede prodotto Desa
- opuscoli
- o etichette energetiche Desa FAS-30BB
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Desa FAS-30BB.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Desa FAS-30BB, manuali di manutenzione, brevi manuali o manuali utente Desa FAS-30BB. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Desa FAS-30BB.

Manuali per l’uso simili

Manuale completo del dispositivo Desa FAS-30BB, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Desa FAS-30BB dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Desa FAS-30BB.

Il manuale per l’uso completo Desa, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Desa FAS-30BB - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Desa FAS-30BB, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Desa FAS-30BB che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Desa FAS-30BB - che ci dovrebbe aiutare nei primi passi durante l'uso Desa FAS-30BB
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Desa FAS-30BB
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Desa FAS-30BB in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Desa FAS-30BB?

Utilizza il modulo sottostante

Se non hai risolto il problema con Desa FAS-30BB con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Desa FAS-30BB è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)