    GAS-FIRED VENTED GAS-FIRED VENTED GAS-FIRED VENTED GAS-FIRED VENTED GAS-FIRED VENTED W W W W W ALL FURNACE ALL FURNACE ALL FURNACE ALL FURNACE ALL FURNACE INST ALLA TION AND OPERA TING INSTRUCTIONS P/N 84502 / REV . 1 1/04 NA TURAL W251F , W351F , W501F L. P . W252F , W352F , W502F G A S W255F , W355F , W505F GA S W256F , W356F , W506F W ARNING: Op ...

  • Louisville Tin and Stove W506 - page 2

    READ CAREFULL Y BEFORE INST ALLING UNIT These installation instructions are a general guide, and do not supersede applicable local codes and ordinances. Before planning or making the installation, be sure it complies with all phases of the local heating codes. Or , in the absence of local codes, with the latest edition of the National Fuel Gas Code ...

  • Louisville Tin and Stove W506 - page 3

    1” 11” 2” SAFETY RULES A) The wall furnace should be located near the center of the house for best heat distribution. B) Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies. C) Children and adults should be alerted to the hazards of high surface temperature and should stay away to avo ...

  • Louisville Tin and Stove W506 - page 4

    COMBUSTION AND VENTILA TION AIR When installed, this gas appliance must be provided with fresh air for combustion, ventilation, and dilution of hot flue gases. The minimum required volume of the area where the appliance is installed should be 50 cubic feet per 1,000 btu/hr . If installed in an area of the home that is considered an unconfined space ...

  • Louisville Tin and Stove W506 - page 5

    VENTING This appliance must be properly connected to a venting system. Consult local ordinances governing venting. Install only UL listed type BW 4” oval gas vent. When the vent enters the attic, a listed type B-1 round flue pipe may be used. See Figure 2, Page 7. V ent pipe must connect to the wall furnace header plate with a “B” vent base p ...

  • Louisville Tin and Stove W506 - page 6

    ROUGH-IN INSTRUCTIONS NOTE: Maximum wall thickness for a dual wall (W501, W502, W505, W506) installation is 5-3/8”. STEP 1. Attach the base plate (purchased with the vent pipe) to the header plate using two No. 8 sheet-metal screws through the pre-punched holes. The heater may not vent properly without a base plate to anchor and seal the vent sys ...

  • Louisville Tin and Stove W506 - page 7

    ROUGH-IN INSTRUCTIONS NOTE: For proper combustion, make sure units are level, front to back and side to side. FIGURE 5A - DR Y W ALL FIGURE 5B - PLASTER W ALL FIGURE 1 ROUGH-IN DIMENSIONS Dry-W all B-W T ype V ent Front Panel Screw Plaster Ground Plaster B-W T ype V ent Screw Front Panel Plaster Ground STEP 4. Remove double ceiling plate between st ...

  • Louisville Tin and Stove W506 - page 8

    B-W VENT FIGURE 3 Casing “Z Bracket Front Panel Front Panel Door FIGURE 5C INST ALLA TION STEP 6. T o place furnace into position, grasp furnace and lift so furnace flue vent and header plate vent opening engage. Do not use burner or gas control to lift heater . Lift furnace upward and swing bottom into wall opening until legs rest on floor plate ...

  • Louisville Tin and Stove W506 - page 9

    CAUTION: Label all wires prior to disconnection when servicing controls. W iring errors can cause improper and dangerous operation. V erify proper operation after servicing. WIRING INSTRUCTIONS – GRA VITY W ALL FURNACE W ARNING: Failure to locate the thermostat properly or to wire the furnace correctly may result in continuous operation, control ...

  • Louisville Tin and Stove W506 - page 10

    A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these in- structions exactly . B . BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor . WHA T TO DO IF YOU SMELL GAS: • Do not try to light any ...

  • Louisville Tin and Stove W506 - page 11

    LIGHTING INSTRUCTIONS MODEL: W251F , W252F / W351F , W352F / W501F , W502F FOR YOUR SAFETY READ BEFORE LIGHTING W ARNING: If you do not follow these instructions exactly , a fire or explosion may r esult causing property damage, personal injury or loss of life. A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, fo ...

  • Louisville Tin and Stove W506 - page 12

    PILOT ADJUSTMENT Locate the pilot adjustment screw on the valve. The pilot flame should surround at least the top 3/8” of the powerpile (pilot generator) or thermocouple (see below). The pilot is unregulated so it will be operating at inlet line pressure (Max. 7” w .c. for natural gas and 1 1” w .c. for propane). T o decrease the pilot flame, ...

  • Louisville Tin and Stove W506 - page 13

    Page 13 MODEL WFF81-C OPTIONAL F AN KIT INST ALL A TION INSTR UCTIONS NO TE: This fan kit is to be installed after installation of wall furnace and with the wall furnace front panel in place. STEP 1 . This appliance, when installed, must be electrically grounded in accordance with local codes, or in the absence of local codes, with the latest editi ...

  • Louisville Tin and Stove W506 - page 14

    Ground WHITE BLACK L2 White 1 15 V AC L1 Black 1 15 V AC BLACK F AN SWITCH BLACK BLACK BLACK MOTO R WHITE GREEN GROUND WIRE L2 White L1 Black 1 15 V AC 60 HZ - Less than 12 Amps. If any of the original wire as supplied with this appliance must be replaced, it must be replaced with type thermoplastic 105 degree C wire or its equivalent. WFF81-C WIRI ...

  • Louisville Tin and Stove W506 - page 15

    TROUBLE SHOOTING CHAR T for qualified serviceman - MAIN BURNER SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Flame too lar ge 1. Defective operator section of gas valve. 1. Replace complete valve. 2. Burner orifice too large. 2. Check with local gas company for proper orifice size and replace. 3. If installed above 2,000 ft. 3. Refer to orifice chart, ...

  • Louisville Tin and Stove W506 - page 16

    SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION Burner won’t 1. Pilot flame too lar ge or too small. 1. Re-adjust pilot flame using adjustment on turn on combination control valve. 2. Dirt in pilot orifice. 2. Clean pilot orifice with air or solvent, do not ream. 3. Defective automatic pilot section in 3. Replace entire combination control valve. combi ...

  • Louisville Tin and Stove W506 - page 17

    SINGLE W ALL FURNACE Model Numbers Nat. L.P . W251F W252F W351F W352F W255F W256F W355F W356F DUAL W ALL FURNACE Model Numbers Nat. L.P . W501F W502F W505F W506F NOTICE: When ordering any component in the Burner Assembly , specify either Honeywell or Robertshaw components. REV . 08/02 Page 17 Prices and specifications subject to change without noti ...

  • Louisville Tin and Stove W506 - page 18

    HOW TO PROPERL Y ORDER P A R TS: In addition to part description and part number, please give model number , serial number , and type of gas used. This information can be found on the rating plate that is attached to heater . Mr . Contractor , we only sell parts through our wholesalers, but the prices listed are for your convenience. For prompt par ...

  • Louisville Tin and Stove W506 - page 19

    IMPOR T ANT SAFETY BULLETIN ON YOUR GAS CONTROL AND PILOT LIGHT SYSTEM FOR HEA TING EQUIPMENT WHA T YOU DON’T KNOW CAN HURT YOU. Y our pilot light system has been designed for safe and reliable operation. Although safety mechanisms are built-in, the potential for hazard exists. This information is intended to help you avoid these hazards. YOUR GA ...

  • Louisville Tin and Stove W506 - page 20

    T ABLE A W arranty for gas appliance heat exchangers only . Product W arranty Period Cozy Gas Fired Floor Furnace 10 Y ears Cozy Gas Fired W all Furnace 10 Y ears Cozy Gas Fired V ented Console Heater 10 Y ears Cozy Gas Fired Direct V ent Heater 10 Y ears Cozy Gas Fired Counterflow Furnace 10 Y ears Cozy Gas Fired Counterflow Direct V ent Furnace 1 ...

Fabbricante Louisville Tin and Stove Categoria Furnace

I documenti che otteniamo dal fabbricante del dispositivoLouisville Tin and Stove W506 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Louisville Tin and Stove
- manuali per l’uso W506
- schede prodotto Louisville Tin and Stove
- opuscoli
- o etichette energetiche Louisville Tin and Stove W506
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Louisville Tin and Stove W506.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Louisville Tin and Stove W506, manuali di manutenzione, brevi manuali o manuali utente Louisville Tin and Stove W506. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Louisville Tin and Stove W506.

Manuale completo del dispositivo Louisville Tin and Stove W506, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Louisville Tin and Stove W506 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Louisville Tin and Stove W506.

Il manuale per l’uso completo Louisville Tin and Stove, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Louisville Tin and Stove W506 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Louisville Tin and Stove W506, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Louisville Tin and Stove W506 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Louisville Tin and Stove W506 - che ci dovrebbe aiutare nei primi passi durante l'uso Louisville Tin and Stove W506
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Louisville Tin and Stove W506
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Louisville Tin and Stove W506 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Louisville Tin and Stove W506?

Utilizza il modulo sottostante

Se non hai risolto il problema con Louisville Tin and Stove W506 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Louisville Tin and Stove W506 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)