Summary
  • Pelco ERD2000 - page 1

    IRD/ERD2000 Series Receiver C1506M-A (8/02) ® INST ALLA TION/OPERA TION ...

  • Pelco ERD2000 - page 2

    2 C1506M-A (8/02) ...

  • Pelco ERD2000 - page 3

    C1506M-A (8/02) 3 CONTENTS Section Page IMPORT ANT SAFEGUARDS AND WARNINGS ..................................................................................... 4 DESCRIPTION ..................................................................................................................................... 5 MODELS ................................ ...

  • Pelco ERD2000 - page 4

    4 C1506M-A (8/02) 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions. 5. Do not block any ventilation openings. Install in accordance with the manufacturer’ s instructions. 6. Do not install near any heat sources, such as radiators, heat registers, stoves, or other apparatus (including amplifi ...

  • Pelco ERD2000 - page 5

    C1506M-A (8/02) 5 The IRD/ERD2000 Series Receiver operates Pelco’ s fixed speed pan/tilts and domes. The receiver works with standard and extended Coaxitron ® controllers, including the CM6700/ 7500/8500/9500, KBD9000, MPT9000/9008/9500, and MX4000. With Coaxitron control, pan/tilt and lens control signals are transmitted over the video coaxial ...

  • Pelco ERD2000 - page 6

    6 C1506M-A (8/02) ERD2200 WIRING E N C L O S U R E POWER O U T L L N N GROUND STUD POWER TERMINALS M A I N POW E R IN Figure 2. ERD2200 Receiver Figure 3. ERD2200 Power Connections 1. Fuses are installed for 115 V AC operation. For 230 V AC operation, install the appropriate fuses (supplied). Refer to Figure 2. 2. Set the power selector switch to e ...

  • Pelco ERD2000 - page 7

    C1506M-A (8/02) 7 A C A C 24V 50/60HZ INPUT POWER ~ 24V ~ 50/60HZ P/T POWER SELECT 115 /230V ~ 50/60HZ A C A C ERD OPTION TLC OUT VIDEO IN PWR CX LENS AUX1 AUX2 C N N OC 24V ,1A ~ I F Z C CAM PWR C C PA N/ T I LT 5V CLASS 2 WIRING ERD OPTIONS 11 5/230V 50/60Hz .60 / .27 AMPS ~ IRD 24V 50/60Hz 1.35 AMPS ~ DEFAUL T SETTING FROM FAC T ORY 115 / 230V R ...

  • Pelco ERD2000 - page 8

    8 C1506M-A (8/02) IRD2024 WIRING 1. Connect power to the 24 V AC INPUT connector on the rear of the receiver . The receiver’ s power requirement is a maximum of 5 V A, not including the camera and pan/tilt. Refer to the pan/tilt manual for its power requirements. Do not turn on power . If necessary , refer to T able A in the Wiring T ables sectio ...

  • Pelco ERD2000 - page 9

    C1506M-A (8/02) 9 When power is applied to the receiver , the green PWR LED on the receiver lights. Whenever the receiver gets a valid Coaxitron control signal, the green CX LED blinks. RANDOM/AUTO SCANNING Operation of random and auto scanning depends on whether your transmitter/controller is communicating with the IRD2000/ERD2200 in standard or e ...

  • Pelco ERD2000 - page 10

    10 C1506M-A (8/02) FUSE REPLACEMENT CAUTION: These service instructions are for use by qualified service personnel only . T o reduce the risk of electrical shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so. IRD2024 Lens/Auxiliary Fuse A 500 mA fuse protects the LENS and AUX ...

  • Pelco ERD2000 - page 11

    C1506M-A (8/02) 11 TROUBLESHOOTING Check the wiring connections. If the CX LED does not blink when commands are sent to the receiver , make sure the controller is working properly . Also check the video coaxial cable between the controller and the VIDEO OUT connection on the receiver . An LRD41TLC T est Local Control Module is available from Pelco ...

  • Pelco ERD2000 - page 12

    12 C1506M-A (8/02) WIRING T ABLES Wire Gauge Table A. 24 VAC Wiring Distances Table The following are the recommended maximum wire distances (transformer to load) for 24 V AC applications and are calculated with a 10-percent voltage drop. (T en percent is generally the maximum allowable voltage drop for AC-powered devices.) Distances are calculated ...

  • Pelco ERD2000 - page 13

    C1506M-A (8/02) 13 SPECIFICA TIONS ERD2200 Electrical Input V oltage: 115/230 V AC, 50/60 Hz Output V oltage Camera: 24 V AC (or 115/230 VAC if using enclosure power) Lens: 8 VDC Pan/T ilt: 24/115/230 VAC Enclosure: 115/230 V AC Power Consumption Receiver: 90 V A maximum, including 48 VA maximum at 24 V AC for pan/tilt and camera (5 V A maximum for ...

  • Pelco ERD2000 - page 14

    14 C1506M-A (8/02) REGULA TORY NOTICES NOTE: This equipment has been tested and found to comply with the limits of a Class B digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radi ...

  • Pelco ERD2000 - page 15

    C1506M-A (8/02) 15 REVISION HISTORY Manual # Date Comments C1506M 3/00 Original version. C1506M-A 8/02 Revised manual per ECO #02-8195 to meet UL standards. Added FCC notice. W ARRANTY Pelco will repair or replace, without charge, any merchandise proved defective in material or workmanship for a period of one year after the date of shipment. Except ...

  • Pelco ERD2000 - page 16

    World Headquarters 3500 Pelco Way Clovis, California 93612 USA USA & Canada Tel: 800/289-9100 Fax: 800/289-9150 International Tel: 1-559/292-1981 Fax: 1-559/348-1120 www.pelco.com ISO 9001 Orangeburg, New York Las Vegas, Nevada Eindhoven, The Netherlands Wokingham, United Kingdom Montreal, Canada ® ...

Fabbricante Pelco Categoria Home Security System

I documenti che otteniamo dal fabbricante del dispositivoPelco ERD2000 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Pelco
- manuali per l’uso ERD2000
- schede prodotto Pelco
- opuscoli
- o etichette energetiche Pelco ERD2000
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Pelco ERD2000.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Pelco ERD2000, manuali di manutenzione, brevi manuali o manuali utente Pelco ERD2000. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Pelco ERD2000.

Manuali per l’uso simili

Manuale completo del dispositivo Pelco ERD2000, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Pelco ERD2000 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Pelco ERD2000.

Il manuale per l’uso completo Pelco, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Pelco ERD2000 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Pelco ERD2000, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Pelco ERD2000 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Pelco ERD2000 - che ci dovrebbe aiutare nei primi passi durante l'uso Pelco ERD2000
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Pelco ERD2000
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Pelco ERD2000 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Pelco ERD2000?

Utilizza il modulo sottostante

Se non hai risolto il problema con Pelco ERD2000 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Pelco ERD2000 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)