Manuale per l’uso Manley Labs 75/150 SE/PP 807 MONOBLOCK

11 pagine 0.04 mb
Scarica

Vai alla pagina of 11

Summary
  • Manley Labs 75/150 SE/PP 807 MONOBLOCK - page 1

    MANLEY LABORATORIES, INC. MANLEY LABORATORIES, INC. 13880 MAGNOLIA AVE. CHINO, CA. 91710 TEL: (909) 627-4256 FAX: (909) 628-2482 email: emanley@netcom.com http://www .manleylabs.com OWNER'S MANUAL 75 / 150 SE / PP 807 MONOBLOCK ...

  • Manley Labs 75/150 SE/PP 807 MONOBLOCK - page 2

    CONTENTS INTRODUCTION 3 READ THIS PAGE 4 MAINS CONNECTION 5 CONNECTING YOUR AMPLIFIER 6 DIAGRAM 2 TOP PANEL 7 BIAS PROCEDURES 8 SPECIFICATIONS 9 WARRANTY 10 WARRANTY REGISTRATION 11 SECTION PAGE ...

  • Manley Labs 75/150 SE/PP 807 MONOBLOCK - page 3

    INTRODUCTION THANK YOU!... for choosing the Manley 75 / 150 SE / PP 807 MONOBLOCK Amplifiers. Designed by David Manley, the 807 MONOBLOCK Amplifiers use only the best available components, with the shortest and cleanest signal path possible. These amps have the exclusive Manley ability to switch from Single ended to Push-Pull topologies. This amp i ...

  • Manley Labs 75/150 SE/PP 807 MONOBLOCK - page 4

    READ THIS PAGE BEFORE YOU SET UP THE AMPS, PLEASE IMPORTANT Never operate this amp without a speaker or load connected. Never drive this amp into a short circuit. Most solid state amps can be operated without a load or speaker and some can drive a short circuit because of protection circuitry. These are different - Like most tube amps the output po ...

  • Manley Labs 75/150 SE/PP 807 MONOBLOCK - page 5

    MAINS CONNECTIONS Your amplifier has been factory set to the correct mains voltage for your country. The voltage setting is marked on the serial badge, located on the rear panel. Check that this complies with your local supply. Export units for certain markets have a moulded mains plug fitted to comply with local requirements. If your unit does not ...

  • Manley Labs 75/150 SE/PP 807 MONOBLOCK - page 6

    CONNECTING YOUR AMPLIFIER Setting up your amplifiers is rather easy. 1. Connect all source components (turntable, CD, Tuner, Tape DAT, etc.) to your preamplifier or switching center. 2. Connect the interconnects from the output of the preamplifier to the RCA input on the top rear of the amplifiers. 3. Connect the hot or "+" speaker cable ...

  • Manley Labs 75/150 SE/PP 807 MONOBLOCK - page 7

    MANLEY 75 / 150 SE / PP 807 TRIODE MONOBLOCK Amplifier Overhead View A B C D E F I K G L J A RCA Input Jack B Speaker Terminals C B PLUS FUSE - Replace only with same type and value (MDL 1.5) D Mains fuse - Replace only with same type and value E IEC Mains socket F Output Transformer G Power Transformer H Power Tube 807 s I Input Tube 5751 J Driver ...

  • Manley Labs 75/150 SE/PP 807 MONOBLOCK - page 8

    OPERATIONAL NOTES SWITCHING SINGLE-ENDED 75 / PUSH-PULL 150 This amplifier has a feature exclusive to Manley Labs of being able to choose between two circuit topologies. You are able to switch between each mode while the amplifier is turned on and playing music. In SINGLE-ENDED mode the amplifier uses eight 807s in parallel. The advantage is a mini ...

  • Manley Labs 75/150 SE/PP 807 MONOBLOCK - page 9

    SPECIFICA TIONS Vacuum Tubes: 8 x 807 (Output), 1 x 7044 (Driver), 1 x 5751 (Input) Output Power @ 3% THD SINGLE-ENDED: - 72 Watts PUSH-PULL: - 150 Watts Frequency Response +/- 1 dB SINGLE-ENDED: 18 Hz - 20 KHz (measured at 5 watts) PUSH-PULL: 10 Hz - 50 KHz Input Sensitivity 1 V nominal Input Impedance 40 KOhm Load Impedance 4 to 12 Ohm appropriat ...

  • Manley Labs 75/150 SE/PP 807 MONOBLOCK - page 10

    W ARRANTY All Manley Laboratories equipment is covered by a limited warranty against defects in materials and workmanship for a period of 90 days from date of purchase to the original purchaser only. A further optional limited 5 year warranty is available to the original purchaser upon proper registration of ownership within 30 days of date of firs ...

  • Manley Labs 75/150 SE/PP 807 MONOBLOCK - page 11

    WARRANTY REGISTRATION We ask that you please fill out this registration form and send the bottom half to: MANLEY LABORATORIES REGISTRATION DEPARTMENT 13880 MAGNOLIA AVE. CHINO CA, 91710 Registration entitles you to product support, full warranty benefits, and notice of product enhancements and upgrades. You MUST complete and return the following to ...

Fabbricante Manley Labs Categoria Stereo Amplifier

I documenti che otteniamo dal fabbricante del dispositivoManley Labs 75/150 SE/PP 807 MONOBLOCK possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Manley Labs
- manuali per l’uso 75/150 SE/PP 807 MONOBLOCK
- schede prodotto Manley Labs
- opuscoli
- o etichette energetiche Manley Labs 75/150 SE/PP 807 MONOBLOCK
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Manley Labs 75/150 SE/PP 807 MONOBLOCK.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Manley Labs 75/150 SE/PP 807 MONOBLOCK, manuali di manutenzione, brevi manuali o manuali utente Manley Labs 75/150 SE/PP 807 MONOBLOCK. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Manley Labs 75/150 SE/PP 807 MONOBLOCK.

Manuale completo del dispositivo Manley Labs 75/150 SE/PP 807 MONOBLOCK, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Manley Labs 75/150 SE/PP 807 MONOBLOCK dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Manley Labs 75/150 SE/PP 807 MONOBLOCK.

Il manuale per l’uso completo Manley Labs, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Manley Labs 75/150 SE/PP 807 MONOBLOCK - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Manley Labs 75/150 SE/PP 807 MONOBLOCK, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Manley Labs 75/150 SE/PP 807 MONOBLOCK che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Manley Labs 75/150 SE/PP 807 MONOBLOCK - che ci dovrebbe aiutare nei primi passi durante l'uso Manley Labs 75/150 SE/PP 807 MONOBLOCK
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Manley Labs 75/150 SE/PP 807 MONOBLOCK
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Manley Labs 75/150 SE/PP 807 MONOBLOCK in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Manley Labs 75/150 SE/PP 807 MONOBLOCK?

Utilizza il modulo sottostante

Se non hai risolto il problema con Manley Labs 75/150 SE/PP 807 MONOBLOCK con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Manley Labs 75/150 SE/PP 807 MONOBLOCK è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)