    Printed in USA AP11564-10 (01/05) WITH INST ALLA TION INSTR UCTIONS FOR THE INST ALLER Light Duty Commercial Electr ic W ater Heater U S E & C A R E MA N U AL ® LISTED 786H The purpose of this manual is twofold: one, to provide the installer with the basic directions and recommendations for the proper installation and adjustment of the water h ...

  • Rheem Light Duty Commercial Electric Water Heater - page 2

    Safety Inf ormation Safety Precautions . . . . . . 3 Installation Instructions Location . . . . . . . . . . . . . . . 4 Water Connections . . . . . . 4 Electrical Connections . 5, 6 Operating Instructions Safety Controls . . . . . . . . . 7 Water Temperature . . . . . . 7 Care and Cleaning Long Time Shut-Down . . . 8 Draining . . . . . . . . . . . ...

  • Rheem Light Duty Commercial Electric Water Heater - page 3

    To meet commercial water use needs, the thermostat on this water heater is adjustable to deliver water up to 170°F. However, water temperatures over 125°F. can cause severe burns instantly or death from scalds. This is the preferred starting point for setting the control for supplying general purpose hot water. Safety and energy conservation are ...

  • Rheem Light Duty Commercial Electric Water Heater - page 4

    1. INSPECT SHIPMENT — Inspect the water heater for possible damage. Check the markings on the rating plate of the water heater to be certain the power supply corresponds to that for which the water heater is equipped. 2. THERMAL EXPANSION — Determine if a check valve exists in the inlet water line. It may have been installed in the cold water l ...

  • Rheem Light Duty Commercial Electric Water Heater - page 5

    5 The pressure rating of the relief valve must not exceed 150 psi (1,034 kPa), the maximum working pressure of the water heater as marked on the rating plate. The BTUH Rating of the relief valve must not be less than the input rating of the water heater as in- dicated on the rating label located on front of the heater (1 watt = 3.412 BTUH). Connect ...

  • Rheem Light Duty Commercial Electric Water Heater - page 6

    A. Water Heater Location ❑ Close to area of heated water demand. ❑ Indoors and protected from freezing temperatures. ❑ Area free of flammable vapors. ❑ Provisions made to protect area from water damage. ❑ Sufficient room to service water heater. B. Water Supply ❑ Water heater completely filled with water. ❑ Water heater and piping air ...

  • Rheem Light Duty Commercial Electric Water Heater - page 7

    7 A. Do turn off power to water heater if it has been subjected to over heating, fire, flood or physical damage. B. Do Not turn on water heater unless it is filled with water. C. Do Not turn on water heater if cold water supply shut-off valve is closed. D. If there is any difficulty in understanding or following the OPERATION or MAINTENANCE instruc ...

  • Rheem Light Duty Commercial Electric Water Heater - page 8

    8 Properly maintained, your water heater will provide years of dependable trouble-free service. It is suggested that a routine preventive maintenance program be established and followed by the user. It is further recommended that a periodic inspection of the operating controls, heating element and wiring should be made by service personnel qualifie ...

  • Rheem Light Duty Commercial Electric Water Heater - page 9

    9 T r ouble Shooting Guide ** For your safety, DO NOT attempt repair of Electrical Wiring, Thermostat(s), Heating Elements or other Operating Controls. Ref er repairs to qualified service personnel. CA UTION ! NATURE OF TROUBLE POSSIBLE CAUSE SERVICE No Hot Water 1. Manual switch turned off Turn to ON 2. Improper Wiring ** Rewire per Wiring Diagram ...

  • Rheem Light Duty Commercial Electric Water Heater - page 10

    10 Replacement P arts List Light Duty Commer cial Models T all or Shor t V er sions Instructions for placing a Parts Orders: Address parts orders to the distributor or store from where the heater was purchased. All parts orders should include: 1. Model number and Serial number of heater (from rating plate). 2. Specify voltage and wattage as marked ...

  • Rheem Light Duty Commercial Electric Water Heater - page 11

    11 Ca vity Inser t Instructions The f ollo wing instructions are intended f or qualified service personnel ONL Y , and should only be done when necessary . In order to replace the thermostat or heating element, remove the cavity insert crossbar by following the instructions below: 1. Turn off the power to the water heater. 2. Remove the jacket acce ...

  • Rheem Light Duty Commercial Electric Water Heater - page 12

    Grounding conductor may be required. Refer to Wiring Section of Manual * This water heater is factory equipped for two (2) wire connection to electrical power . For use with "off-peak" meter (timer) remove wire nut from red and black leads and connect to "off- p eak" meter ( timer ) . ‡ Wiring Diagrams — Therm-O-Disc Thermos ...

Fabbricante Rheem Categoria Water Heater

I documenti che otteniamo dal fabbricante del dispositivoRheem Light Duty Commercial Electric Water Heater possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Rheem
- manuali per l’uso Light Duty Commercial Electric Water Heater
- schede prodotto Rheem
- opuscoli
- o etichette energetiche Rheem Light Duty Commercial Electric Water Heater
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Rheem Light Duty Commercial Electric Water Heater.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Rheem Light Duty Commercial Electric Water Heater, manuali di manutenzione, brevi manuali o manuali utente Rheem Light Duty Commercial Electric Water Heater. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Rheem Light Duty Commercial Electric Water Heater.

Manuali per l’uso simili

Manuale completo del dispositivo Rheem Light Duty Commercial Electric Water Heater, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Rheem Light Duty Commercial Electric Water Heater dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Rheem Light Duty Commercial Electric Water Heater.

Il manuale per l’uso completo Rheem, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Rheem Light Duty Commercial Electric Water Heater - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Rheem Light Duty Commercial Electric Water Heater, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Rheem Light Duty Commercial Electric Water Heater che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Rheem Light Duty Commercial Electric Water Heater - che ci dovrebbe aiutare nei primi passi durante l'uso Rheem Light Duty Commercial Electric Water Heater
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Rheem Light Duty Commercial Electric Water Heater
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Rheem Light Duty Commercial Electric Water Heater in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Rheem Light Duty Commercial Electric Water Heater?

Utilizza il modulo sottostante

Se non hai risolto il problema con Rheem Light Duty Commercial Electric Water Heater con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Rheem Light Duty Commercial Electric Water Heater è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)