TDK iHA48060A012V - page 1
Advanced Data Sheet: Veta iHA48060A012V*, 1. 2V/60A Output Half Brick Series ©2007 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 1 / 16 Advanced Datasheet DC - DC Power Modules Veta iHA48060A012V* Half Brick Series 48V Input, 1.2V/60A Output Information furnished by TDK Innoveta is believe d to be accurate a nd reliable. H ...
-
TDK iHA48060A012V - page 2
Advanced Data Sheet: Veta iHA48060A012V*, 1. 2V/60A Output Half Brick Series ©2007 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 2 / 16 Platform Overview: Veta iHA 48 Series DC - DC Power Modules 48V Input, 1.2 - 28V/6 0A or 3 50 W Output Half - Brick The Veta iHA48 Series power modules operate over a wide 36 – 75Vdc ...
-
TDK iHA48060A012V - page 3
Advanced Data Sheet: Veta iHA48060A012V*, 1. 2V/60A Output Half Brick Series ©2007 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 3 / 16 Ordering information: Product Identifier Package Size Platform Input Voltage Output Current/ Power Output Units Main Output Voltage # of Outputs Safety Class Feature Set i H A 48 060 A 033 V - ...
-
TDK iHA48060A012V - page 4
Advanced Data Sheet: Veta iHA48060A012V*, 1. 2V/60A Output Half Brick Series ©2007 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 4 / 16 Mechanical Specification : Unless otherwise specified tolerances are: x.x ± 0.5 mm [x.xx ± 0.02 in.] , x.xx +/ - 0.25 mm [x.xxx +/ - 0.010 in.] Recommended Hole Pattern : (top view) Pin Assi ...
-
TDK iHA48060A012V - page 5
Advanced Data Sheet: Veta iHA48060A012V*, 1. 2V/60A Output Half Brick Series ©2007 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 5 / 16 Absolute Maximum Ratings : Stress in excess of Absolute Maximum Ratings may cause permanent damage to the device. • Engineering estimate Common Input Characteristics : Unless otherwise speci ...
-
TDK iHA48060A012V - page 6
Advanced Data Sheet: Veta iHA48060A012V*, 1. 2V/60A Output Half Brick Series ©2007 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 6 / 16 Electrical Data (continued) : Operating at Tc = 25 °C unless otherwise spec ified Output Characteristic Min Typ Max Unit Notes & Conditions Output Voltage Initial Setpoint 1.18 1.2 1.22 V ...
-
TDK iHA48060A012V - page 7
Advanced Data Sheet: Veta iHA48060A012V*, 1. 2V/60A Output Half Brick Series ©2007 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 7 / 16 Electrical Characteristics: iHA48060A012V-001 Efficiency 70 75 80 85 90 6 12 18 24 30 36 42 48 54 60 Output Current (A) Efficiency, η (%) Vin = 36V Vin = 48V Vin = 75V Ta = 25 Deg C. iHA48060 ...
-
TDK iHA48060A012V - page 8
Advanced Data Sheet: Veta iHA48060A012V*, 1. 2V/60A Output Half Brick Series ©2007 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 8 / 16 Electrical Characteristics (continued): iHA48060A012V-001 Current Limit 0 0.2 0.4 0.6 0.8 1 1.2 1.4 6 16 26 36 46 56 66 76 86 Output Current (A) Output Voltage (V) Vin = 36V Vin = 48V Vin = 75 ...
-
TDK iHA48060A012V - page 9
Advanced Data Sheet: Veta iHA48060A012V*, 1. 2V/60A Output Half Brick Series ©2007 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 9 / 16 Electrical Characteristics (continued): 1 10 100 1000 0.65 0.70 0.75 0.80 0.85 0.90 0.95 1.00 1.05 1.10 1.15 1.20 Desired Decreased Output Voltage (V) Trim Resistance (k Ω ) 0.01 0.10 1.00 1 ...
-
TDK iHA48060A012V - page 10
Advanced Data Sheet: Veta iHA48060A012V*, 1. 2V/60A Output Half Brick Series ©2007 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 10 / 16 Thermal Performance : 10 20 30 40 50 60 30 40 50 60 70 80 90 100 110 120 Ambient Temperature ( o C) Output Current (A) NC (0.3 m/s, 60 LFM) 1.0 m/s (200 LFM) 2.0 m/s (400 LFM) IMS LIMIT < ...
-
TDK iHA48060A012V - page 11
Advanced Data Sheet: Veta iHA48060A012V*, 1. 2V/60A Output Half Brick Series ©2007 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 11 / 16 Thermal Management: An important part of the overall system design process is thermal management; thermal design must be considered at all levels to ensure g ood reliability and lifetime of t ...
-
TDK iHA48060A012V - page 12
Advanced Data Sheet: Veta iHA48060A012V*, 1. 2V/60A Output Half Brick Series ©2007 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 12 / 16 Heat transfer by convection can be enhanced by increasing the airflow rate that the power module experiences. The maximum output current of the power module is a function of ambient temperatu ...
-
TDK iHA48060A012V - page 13
Advanced Data Sheet: Veta iHA48060A012V*, 1. 2V/60A Output Half Brick Series ©2007 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 13 / 16 Operating Information: Over - Current Protection: The power modules have current limit protection to protect the module during output overload and short circuit conditions. During overload co ...
-
TDK iHA48060A012V - page 14
Advanced Data Sheet: Veta iHA48060A012V*, 1. 2V/60A Output Half Brick Series ©2007 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 14 / 16 percentage of Vout (%Vo) from Vo,nom, the trim resistor should be chosen a ccording to the following equation: 1 . 0 1 968 . 0 − − = Vdown Vnom Rdown k Ω The current limit set point doe ...
-
TDK iHA48060A012V - page 15
Advanced Data Sheet: Veta iHA48060A012V*, 1. 2V/60A Output Half Brick Series ©2007 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 15 / 16 Input/Output Ripple and Noise Measurements: 100KHz Voutput Cext 1 2 + 12uH 1 2 esr<0.7 Battery 100KHz + RLoad 1 2 esr<0.1 - Vinput 220uF 1 2 Ground Plane 33uF 1 2 - The input reflected ...
-
TDK iHA48060A012V - page 16
Advanced Data Sheet: Veta iHA48060A012V*, 1. 2V/60A Output Half Brick Series ©2007 TDK Innoveta Inc. iHA Datasheet 040207 ' (877) 498 - 0099 16 / 16 than 2 M hours using the Telcord ia TR - 332 calculation method. Improper handling or cleaning processes can adversely affect the appearance, testability, and reliability of the power modules ...
Hai una domanda su TDK iHA48060A012V?
Utilizza il modulo sottostante
Se non hai risolto il problema con TDK iHA48060A012V con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con TDK iHA48060A012V è probabile che voglia condividere il modo di risolverlo.