    Part No . 312865- C January 200 2 4401 Gr eat Ame rica Parkwa y Santa Clara, CA 95054 *312865-C* Install ing Giga bit Interface Converters , SFP , and CWDM SFP Gigabit In terface Converters CWGBIC.fm Page -1 W ednesday, December 12, 2001 11:26 AM ...

  • Nortel Networks CWDM SFP - page 2

    Copyright © 2002 Nortel Networks All rights re served. January 2002 . The information i n this document is subject to change without notice. The statements, configuration s, technical data, and recom mendations in this docum ent are believed to be accurate and reliable, but are presented without express or implied warranty . Users m ust take full ...

  • Nortel Networks CWDM SFP - page 3

    1 Product Safety Meets requirements of: CSA 22.2 No. 950-M95/UL1950, 3rd ed. EN60950: 1992 /A1:1993 /A2:1993 /A3: 1995 /A4: 199721CFR, Chapter I EN60825-1:1994 /A11:1996 Caution: Only qualifie d technicians should ins tall thi s equipm ent. Place all pri nted circuit boa rds on an antistatic mat until you are rea dy to instal l them. I f you do not ...

  • Nortel Networks CWDM SFP - page 4

    2 Introduct ion to Gigabit Inter face Converters This section d esc ribes th e Gigabit In terface Con verter (GBIC) and label, and provides a GBIC model list. Product desc ription Gigabit Interface Con verters (GBICs) are hot-swappabl e input/ output enh ancement componen ts design ed for u se with Nortel Networks* products to allo w Gigabit E ther ...

  • Nortel Networks CWDM SFP - page 5

    3 Figure 1 GB IC extraction t abs and extra ctor handl e GBIC labeli ng The Nortel Networks labe l on a typical GB IC (Figure 2) contains a Nortel Netwo rks serial numbe r , a ba r code, a manufact urer ’ s code, an int erface type, an d a part number . Figure 2 Nortel Networks GBIC label 9702F A GBIC model with extr actor tabs GBIC model with ex ...

  • Nortel Networks CWDM SFP - page 6

    4 GBIC and SFP G BIC model list Ta b l e 1 lists and de scri bes th e No rtel N etwork s GBIC and S FP GBIC models. No te: When yo u contact a Nortel Networks servic e represe ntati ve for trouble shoot ing pur poses, you mu st have t he following information availabl e : • Nortel Network s serial number • Manuf act urer ’ s cod e • Interfa ...

  • Nortel Networks CWDM SFP - page 7

    5 Handling, safet y , and environmental guidelines Before installin g your GBIC, read the follo wing handlin g, safety , and envi ronmental g uidelines: • GBICs are static sens itive. T o prevent damage from electrostat ic discharge (ESD), follow your no rmal board and com ponent hand ling pro cedure s. • GBICs are dust sensitive. Whe n you sto ...

  • Nortel Networks CWDM SFP - page 8

    6 2 V erify that the GBIC i s the correct model for your network config uration ( T abl e 1 on page 4 ). 3 Remove the dust cover from the GBIC ’ s optical bores. 4 Grasp the GBIC between you r thumb and forefi nger . 5 Insert the GBIC i nto the sl ot on the fro nt pan el of the Giga bit Etherne t swit ching modul e (Figure 3) . Figure 3 Inser tin ...

  • Nortel Networks CWDM SFP - page 9

    7 2 Depen ding on you r GBIC mo del, e ither grasp the ex traction tabs ( Figure 1 ) located on e ither side of the GBIC with your thumb an d forefin ger , or lift the ex tractor h andle ( Figure 1 ) attached to the GBIC. 3 Slide the GBIC ou t of the Gigabit E thernet module sl ot. 4 If the GBIC does not slid e easily from the modu le slot, use a g ...

  • Nortel Networks CWDM SFP - page 10

    8 Standards, connect ors, cabling, and distance This section desc ribes GBIC standards , connectors, cab ling, and distance; and provides specifi cations for the fo llowing GBICs: • “ 1000BA SE-SX, ” next • “ 1000B ASE-L X ” on page 9 • “ 1000B ASE-XD ” on page 1 1 • “ 1000B ASE-Z X ” on page 13 • “ 1000B ASE-T ” on pa ...

  • Nortel Networks CWDM SFP - page 11

    9 1000BA SE-LX The Mode l 1000BASE-L X GBIC prov ides 1000 BASE-LX (1300 n m, wavele ngth, Giga bit Eth ernet) co nnectivi ty usin g SC duple x fiber co nnector s. The lon g waveleng th optic al transceivers use d in th e LX model p rovide v ariable distan c e ranges us ing bot h multimo de and sin gle-mo de fiber opt ic cablin g. The Mode l 100 0B ...

  • Nortel Networks CWDM SFP - page 12

    10 Ta b l e 4 describes standards, con nectors, cabling , and distance for the Mod el 1000BASE- LX GBIC. T able 4 100 0BASE-LX sp ecifications Type Specifications Standar ds Confor mity to the f ollowing sta ndards: 802.3z, 100 0BASE-LX Connect ors Duplex L C fiber opti c connecto r Cabl ing 62.5 µm MM F optic cable 50 µm MMF o ptic cable 10 µm ...

  • Nortel Networks CWDM SFP - page 13

    11 1000BASE-XD The Model 1000BASE-XD GBIC provides Gi gabit Ethern et connec tivity usi ng SC dupl ex single -mode f iber conne ctors. High-perfo rmance optica l transceivers ena ble Gigabi t Ethernet link dist ances up t o 50 kilome ters (k m) over sing le-mod e fiber . The port s operate in full- duplex mo de only . Ta b l e 5 describes standards ...

  • Nortel Networks CWDM SFP - page 14

    12 Connect ors Duplex SC si ngle-mo de fiber o ptic connec tor Cabling Single-m ode fibe r optic cable Dist ance Up to 50 km usi ng si ngle -mode fib er cable, de pending on the qualit y of the fiber Optical b udget 17 dB Laser T ransmitt er Char acterist ics Waveleng th 1550 ± 10 nm Maximu m spectral wi dth 0.2 nm Maximu m launc h power 0 dBm o r ...

  • Nortel Networks CWDM SFP - page 15

    13 1000BA SE-ZX The Mode l 1000BASE-Z X GBIC prov ides Gigabi t Ether net connec tivity usi ng SC dupl ex single -mode f iber conne ctors. High-perfo rmance optica l transceivers ena ble Gigabi t Ethernet link dista nces up to 70 km over sing le-mode fi ber cable. Th e ports operate in fu ll-dup lex mo de onl y . Ta b l e 6 describes standards, con ...

  • Nortel Networks CWDM SFP - page 16

    14 Dis tanc e 7 0 km Receiver Characteristics Wavelength 1200 to 1550 nm Minimum receiver sen sitivity -22 dBm Maximum i nput power -3 dBm No te: Whe n shorter lengths of single -mode fiber cable are used, there is a risk of overl oading the receive r . It may be ne cessary to insert an in-line op tical atte nuato r in the li nk to p revent ov erlo ...

  • Nortel Networks CWDM SFP - page 17

    15 1000BA SE-T The Mode l 1000BASE -T G BIC provid es 1000BASE-T (Gig abit Ethern et) connec tivity . Ta b l e 4 describes standards, con nectors, cabling , and distance for the Mod el 1000BASE- LX GBIC. T able 7 100 0BASE-LX sp ecifications Type Specifications Standar ds Confor mity to the f ollowing sta ndards: IEEE 802.3 z and IEEE 802.3AB Conne ...

  • Nortel Networks CWDM SFP - page 18

    16 Introduct ion to Small Form Factor Plugg able (SFP) Gigabit Int erface Converte rs This sectio n describe s the Sma ll Form F actor Plug gable (SFP) Gigabit Interface Con verter (GBIC) and label, and provides a SFP GBIC m odel list. Product desc ription Small Form Factor Pl uggable Gigabit In terface Converte rs (SFP GBICs) ar e hot-sw appable i ...

  • Nortel Networks CWDM SFP - page 19

    17 SFP GBIC labe ling The Norte l Networks lab e l on a typical SFP GBIC (Figure 5) contains a No rtel Networks seria l number , a bar code, a manu facture r ’ s code, an i nterface type, and a par t number. Figure 5 Nortel Networks SFP GBIC label No te: When yo u contact a Nortel Networks servic e represe ntati ve for trouble shoot ing pur poses ...

  • Nortel Networks CWDM SFP - page 20

    18 SFP GBIC mod el list Ta b l e 8 lists and de scribes the Nortel Network s SFP GBIC models. Handling, safet y , and environmental guidelines Before insta lling y o ur SF P GBIC, rea d the follo wing handling, safety , and environme ntal gu idelines: • SFP GBICs a re static sen sitive. T o prevent d amage f rom electrostat ic discharge (ESD), fo ...

  • Nortel Networks CWDM SFP - page 21

    19 • SFP G BICs are du st sensitive . When you store a SFP GBIC, or when yo u disconn ect it from a f iber optic cable, al ways keep the dust cov er over the SFP GBIC ’ s optical bores. • T o clean contam inants from the opt ical bores of a SFP G BIC, use an alco hol swab or equival ent to clean the ferrules of the optical connector. • Disp ...

  • Nortel Networks CWDM SFP - page 22

    20 Figure 6 Inser ting a LC SFP G BIC Figure 7 Inserting a MT -RJ SFP GBIC No te: SFP GBICs are keyed to prevent incorrect insertion. Link Act BPS2000-2GE MDA Link Act BPS2000-2GE MDA CWGBIC.fm Page 20 Wednesday, December 12, 2001 11:26 AM ...

  • Nortel Networks CWDM SFP - page 23

    21 Removing a Small Form Factor Pluggable (SFP) GB IC This section lists the steps for removing a GBIC. T o remove a GBIC: 1 Disconne ct the netwo rk fiber cabl e from the SF P GBIC connect or . 2 Depend ing on your SFP GBIC mo del, either p ull the LC extracti on tab located in the f ront of the SFP GBIC (below righ t) wit h your thumb an d foref ...

  • Nortel Networks CWDM SFP - page 24

    22 5 Dispose of the S FP GBIC according to all nat ional laws and regul ations . Small Form Factor Pluggable (SFP) GBIC specificat ions Ta b l e 9 describes gene ral SFP GBIC sp ecifications. Standard s, connectors , cabling, and distan ce This sect ion desc ribes SF P GBIC stan dards, co nnectors, cabling , and distan ce; and provides sp ecificati ...

  • Nortel Networks CWDM SFP - page 25

    23 1000BASE-SX (LC T ype) The Mode l 1000BASE-S X SFP GBIC provi des 1000 BASE-SX (850 n m, short wa velength, Gi gabi t Etherne t) c onnectiv ity using LC duple x multi mode fibe r connect ors.Th e Model 10 00BASE- SX SFP GBIC su pports full-duplex o peration only . Ta b l e 1 0 describ es standards, conn ectors, ca bling, and dist ance for the Mo ...

  • Nortel Networks CWDM SFP - page 26

    24 1000BASE-LX (LC T ype) The Mod el 1000 BASE-LX S FP GBIC pr ovide s 1000B ASE-LX (1300 n m, wavele ngth, Giga bit Eth ernet) co nnectivi ty usin g LC duplex f iber conn ectors. The lon g waveleng th optical transceivers use d in th e LX model p rovide v ariable distan c e ranges us ing bot h multimo de and sin gle-mo de fiber opt ic cablin g. Th ...

  • Nortel Networks CWDM SFP - page 27

    25 1000BASE-SX (M T -RJ T ype) The Model 10 00BASE-SX (MT -RJ T ype) SFP GBIC provides Gigabi t Ethernet connect ivity usin g MT -RJ mu lti-mo de fiber connectors. Ta b l e 1 2 describ es standards, conn ectors, ca bling, and dist ance for the Model 1 000BASE-SX (MT -RJ T ype) SFP GBIC. Waveleng th 1300 nm Optical b udget 10.5 dB Laser T ransmitt e ...

  • Nortel Networks CWDM SFP - page 28

    26 Cabl ing 62.5 µm MMF opt ic ca ble 50 µm MMF o ptic cable Dist ance 275 mm (62.5 µm MMF opt ic ca ble) 550 mm ( 50 µm MMF o ptic cable) Optical b udget 7 dB Laser T ransmitt er Char acterist ics Waveleng th 850 nm Maximu m spect ral width 0.8 5 nm Maximu m launc h power -4.0 d Bm Minimum launch power into fiber -9.5 dB m Rece iver Char acter ...

  • Nortel Networks CWDM SFP - page 29

    27 Introduct ion to Coarse W avelength Division Mult iple xed (CW DM) Small F orm Fac tor Pluggable ( SFP) Giga bit Inte rface Converters This section d escribes how th e Nortel Network s* coarse waveleng th divisi on mult iple xed Small F orm Factor Pluggab le Gigabit Interface Conve rter (CWDM SFP GBIC) works within the optical routing syste m. I ...

  • Nortel Networks CWDM SFP - page 30

    28 CWDM SFP G BIC Listi n g Ta b l e 1 3 lists the Nortel Networks CWDM SFP GBICs and descri bes their wavele ngths, color c odes, pa rt numbe rs, and c able lengths. T able 13 Nortel Networks CWDM SFP GBIC List CWDM SFP GBIC Product number Cabl e Length 1470nm/G ray AA141 9025 AA14 19033 40 KM 70 KM 1490nm/V iolet AA1 419026 AA14 19034 40 KM 70 KM ...

  • Nortel Networks CWDM SFP - page 31

    29 CWDM SFP GBIC specifications No te: CWDM SF P GBICs are in stalled an d re moved like any other LC type SFP GBIC. T able 14 CWDM SFP GBIC specifications Item Specification Physical dim ensions 0.457 X .604 X 2.18 inche s (11.6 X 15.3 X 55. 43 mm) Connect ors Duplex LC fiber optic Cablin g SMF, 9 µm Data rate Nominal range 1.0625 to 125 0 Mbaud ...

  • Nortel Networks CWDM SFP - page 32

    30 No te: A minim um attenuat ion of 5 dB mu st be present between the transmitt er and re ceiver . T o avoid receiver saturation, you must insert a m inimum attenua tion of 5 dB whe n: • test ing the CW DM SFP GBIC in loop back mode • using shor t runs of fib er with n o intermedia te CWDM OADM or CWDM OMUX T o determine th e expected signa l ...

  • Nortel Networks CWDM SFP - page 33

    31 Connecting t o Nortel Net works online This secti on describes pr oducts, services, an d support systems that can be acc essed onlin e. Hard-copy technica l m anuals Y o u can print selec ted techni cal manuals and rel ease not es free, directly from the Internet. Go to the www .nortelnetworks.co m/ docume ntatio n URL. Find t he product for whi ...

  • Nortel Networks CWDM SFP - page 34

    32 If you pu rchased a Nortel Netwo rks service p rogram, contact on e of the fo llowing No rtel Netwo rks T echnical Solution s Centers : An Express Routing Code (ERC) is av ailable for many Nortel Network s product s and services. When you use an ERC, yo ur call is routed to a techni c al suppo rt person who specialize s in supp orting that prod ...

Fabbricante Nortel Networks Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoNortel Networks CWDM SFP possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Nortel Networks
- manuali per l’uso CWDM SFP
- schede prodotto Nortel Networks
- opuscoli
- o etichette energetiche Nortel Networks CWDM SFP
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Nortel Networks CWDM SFP.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Nortel Networks CWDM SFP, manuali di manutenzione, brevi manuali o manuali utente Nortel Networks CWDM SFP. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Nortel Networks CWDM SFP.

Manuale completo del dispositivo Nortel Networks CWDM SFP, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Nortel Networks CWDM SFP dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Nortel Networks CWDM SFP.

Il manuale per l’uso completo Nortel Networks, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Nortel Networks CWDM SFP - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Nortel Networks CWDM SFP, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Nortel Networks CWDM SFP che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Nortel Networks CWDM SFP - che ci dovrebbe aiutare nei primi passi durante l'uso Nortel Networks CWDM SFP
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Nortel Networks CWDM SFP
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Nortel Networks CWDM SFP in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Nortel Networks CWDM SFP?

Utilizza il modulo sottostante

Se non hai risolto il problema con Nortel Networks CWDM SFP con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Nortel Networks CWDM SFP è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)