    Room Air Conditioner Installation and Operating Manual MODEL NUMBER SERIAL NUMBER PURCHASE DATE 920-138-00 (01/02) KQ08E10 Registering Your Room Air Conditioner Model information can be found on the name plate located on the side of the unit near the control panel. Please complete and mail the owner registration card furnished with this product or ...

  • Friedrich KQ08E10 - page 2

    Congratulations! Y ou have pur chased a Friedric h KStar ® r oom air conditioner . The Friedrich KStar ® is designed to pr ovide maxim um comf or t and quietness. T able of Contents Intr oduction ..................................................................................2 Safety Precautions ................................................. ...

  • Friedrich KQ08E10 - page 3

    Bef ore Operating Y our Unit Make sure the wiring is adequate f or your unit. If you have fuses, they should be of the time delay type. Before you install or relocate this unit, be sure that the amperage rating of the circuit breaker or time delay fuse does not exceed the amp rating listed in figure 1. DO NO T use an extension cord. The cord provid ...

  • Friedrich KQ08E10 - page 4

    WARNING Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. ■ Incorrect operation due to ignoring of instruction will cause harm or damage, the seriousness is classified by the following indications. 3 W ARNING This symbol indicates the possibility of death or serious ...

  • Friedrich KQ08E10 - page 5

    4 Sharp edges Safety Precautions When the air filter is to be removed, do not touch the metal parts of the unit. • It may cause an injury. Do not clean the air conditioner with water. • Water may enter the unit and degrade the insulation. It may cause an electric shock. Ventilate well when used together with a stove, etc. • An oxygen shortage ...

  • Friedrich KQ08E10 - page 6

    5 Ho w to Operate Y our KStar ® Room Air Conditioner The controls will look like the f ollowing. Controls • FOR NORMAL COOLING 1. Turn the Mode switch to the High, Med, or Low Cool setting. 2. Set the Temperature control to the desired temperature point (the mid-point is a good starting position). If the room temperature is not satisfactory afte ...

  • Friedrich KQ08E10 - page 7

    6 VENT CLOSE OPEN Pa r t A Pa r t B The direction of air can be controlled horizontally or vertically by using the horizontal louver or vertical louver. Horizontal Air-Direction The horizontal air direction is adjusted by moving the inside louvers to the left or right. Vertical Air-Direction The vertical (up or down) air direction is adjusted by ap ...

  • Friedrich KQ08E10 - page 8

    Care and Maintenance The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary. The grille is designed to clean the filter both upward and downward. • T o Remove the Filter 1. Remove the front cover by gripping the top outside edges and pulling toward you. You will notice that the ...

  • Friedrich KQ08E10 - page 9

    8 Installation Instructions Electrical Data NOTE TO INSTALLER: Leave these instructions with the air conditioner after installation is completed. NOTE TO CONSUMER: Keep this Installation and Operating Manual for future use. Important notes: It is recommended that proper attire be worn during installation. For personal safety, this air conditioner m ...

  • Friedrich KQ08E10 - page 10

    Installation Instructions 9 SITUATIONS WHERE THE APPLIANCE WILL BE DISCONNECTED ONLY OCCASIONALLY: ❒ Because of potential safety hazards, we strongly discourage the use of an adapter plug. However, if you wish to use an adapter, a TEMPORARY CONNECTION may be made. Use UL-listed adapter, available from most local hardware stores. The large slot in ...

  • Friedrich KQ08E10 - page 11

    10 1 7 2 3 4 5 14 10 11 9 12 13 8 Type C (5) Type A (13) Bolt (2) Nut (2) Type B (3) Foam top window gasket Window sash seal Right frame curtain Window locking bracket Left frame curtain Frame guide(2) Sill support(2) 6 Installation Instructions Learning part names prior to installation will help you understanding the installation procedure. 1. CAB ...

  • Friedrich KQ08E10 - page 12

    11 Over 20" About 1/2" HEAT RADIATION FENCE AWNING COOLED AIR 30"~60" Level 1/4 Bubble 22" to 36" 15" min Stool Offset 1/2" to 1 1 / 4 " 18 1 / 2 " min Sill Exterior Interior wall (Without frame curtain) (With accordion panels) (With frame curtain) Storm window frame W ood Stool 1/2" higher tha ...

  • Friedrich KQ08E10 - page 13

    12 Window sash seal Frame guide Bottom of case (Type A) (Type A) Shipping screws ✓ Remove the 2 shipping screws from the back of the case. ✓ Remove the 2 screws on each side of the case. Keep these for later use. ✓ Slide the air conditioner from the case by gripping the base pan handle and pulling forward while bracing the case. ✓ Cut the w ...

  • Friedrich KQ08E10 - page 14

    13 Top mounting rail Front angle Window stool Sash seal Cabinet Frame curtains INDOOR OUTDOOR Sill Support Nut Bolt INDOOR OUTDOOR ABOUT 1/2" Cabinet Screw(T ype A) F rame guide (T ype C) Screw Sash T rack F ront Angle Screw(T ype B) Sill Suppor t (T ype C) Screw Foam top window gasket Top mountaing rail Window Sash Step 1. Open the window and ...

  • Friedrich KQ08E10 - page 15

    14 Power Cord Screw Screw Inlet Grille Step 1. Slide the air conditioner into the case. Reinstall the 2 screws removed earlier on each side of the case. Step 2. Before installing the front grille, pull out the vent control lever located above the unit control knobs, as shown. Step 3. A t tach the front grille to the case by inserting the tabs on th ...

  • Friedrich KQ08E10 - page 16

    15 ? T roub leshooting Tips Troubleshooting Tips Save time and money! Review the chart below first and you may not need to call for service. Problem Possible Causes What To Do ■ The air conditioner is unplugged. ■ The fuse is blown/circuit breaker is tripped. ■ Power failure. ■ Airflow is restricted. ■ The THERMOSTAT may not be set high e ...

  • Friedrich KQ08E10 - page 17

    16 ROOM AIR CONDITIONERS LIMITED WARRANTY FIRST YEAR SECOND THROUGH FIFTH YEAR SEALED REFRIGERANT SYSTEM: If the sealed refrigeration system (defined for this purpose as the compressor, condenser coil, evaporator coil, reversing valve, check valve, capillary, filter drier, and all interconnecting tubing) supplied by FRIEDRICH in your Room Air Condi ...

  • Friedrich KQ08E10 - page 18

    920-138-00 (01/02) Post Office Box 1540 • 4200 N. Pan Am Expressway • San Antonio, Texas 78295-1540 • (210) 357-4400 • FAX (210) 357-4480 FRIEDRICH AIR CONDITIONING CO. Visit our web site at www.friedrich.com P/NO.: 3828A20196J ...

Fabbricante Friedrich Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoFriedrich KQ08E10 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Friedrich
- manuali per l’uso KQ08E10
- schede prodotto Friedrich
- opuscoli
- o etichette energetiche Friedrich KQ08E10
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Friedrich KQ08E10.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Friedrich KQ08E10, manuali di manutenzione, brevi manuali o manuali utente Friedrich KQ08E10. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Friedrich KQ08E10.

Manuali per l’uso simili

Manuale completo del dispositivo Friedrich KQ08E10, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Friedrich KQ08E10 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Friedrich KQ08E10.

Il manuale per l’uso completo Friedrich, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Friedrich KQ08E10 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Friedrich KQ08E10, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Friedrich KQ08E10 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Friedrich KQ08E10 - che ci dovrebbe aiutare nei primi passi durante l'uso Friedrich KQ08E10
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Friedrich KQ08E10
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Friedrich KQ08E10 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Friedrich KQ08E10?

Utilizza il modulo sottostante

Se non hai risolto il problema con Friedrich KQ08E10 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Friedrich KQ08E10 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)