Manuale per l’uso Campbell Manufacturing DB1

18 pagine 0.8 mb
Scarica

Vai alla pagina of 18

Summary
  • Campbell Manufacturing DB1 - page 1

    DB1 Liquid Level Measurement Sensor Revision: 12/07 Copyright © 1993-2007 Campbell Scientific, Inc. ...

  • Campbell Manufacturing DB1 - page 2

    Warranty and Assistance The DB1 LIQUID LEVEL MEASUREMENT SENSOR is warranted by CAMPBELL SCIENTIFIC, INC. to be free from defects in m aterials and workmanship under norm al use and service for twelve (12) m onths from date of shipment unl ess specified otherwise. Bat teries have no warranty. CAMPBELL SCIENTIFIC, INC.'s obligation under this w ...

  • Campbell Manufacturing DB1 - page 3

    DB1 Table of Contents PDF viewers note: These page numbers refer to the printed version of this document. Use the Adobe Acrobat® bookmarks tab for links to specific sections. 1. Overview ....................................................................... 1 2. Specifications .............................................................. 2 3. In ...

  • Campbell Manufacturing DB1 - page 4

    This is a blank page. ...

  • Campbell Manufacturing DB1 - page 5

    DB1 Liquid Level Measurement Sensor 1. Overview The double bubbler is a self-cali brating system for l iquid level m easurement. This manual focuses on water level measurement in stilling wells o r open channels, but the inform ation applies to other l iquids as well. The system detects water level by measuring the pressure required t o force a nit ...

  • Campbell Manufacturing DB1 - page 6

    DB1 Liquid Level Measurement Sensor 2. Specifications Measurement Range: Option - 5 (0 to 5 psi/0 to 11.5 ft.) Option - 15 (0 to 15 psi/0 to 34.5 ft.) Option - 30 (0 to 30 psi/0 to 69 ft .) Maximum Overpressure Range: Option - 5 20 psi Option - 10 45 psi Option - 15 60 psi Transducer Accuracy: ± 0.05 % Full Scale Temperature Range: -25 ° to + 50 ...

  • Campbell Manufacturing DB1 - page 7

    DB1 Liquid Level Measurement Sensor fluctuates between 5 and 15 ft (2.2 a nd 6.5 psi ), set the pressure regulator above 7 psi (read 10 psi) to ensure adequate pressure. Open the nitrogen bottle valve, set the p ressure regulator, an d adjust the nitrogen flow by adjusting t he two needle valves. The suggested bubble rate is 1 to 3 bubbles/seconds. ...

  • Campbell Manufacturing DB1 - page 8

    DB1 Liquid Level Measurement Sensor FIGURES 1 and 2. The DB1 System 4 ...

  • Campbell Manufacturing DB1 - page 9

    DB1 Liquid Level Measurement Sensor CR10(X) , CR1000, CR 800 CR850, 21X FIGURE 3. Wiring Diagram for DB1 5 ...

  • Campbell Manufacturing DB1 - page 10

    DB1 Liquid Level Measurement Sensor 5. Programming Every 60 seconds, the following program examples calcul ate the pressure transducer multiplier, measure the offset, and measure the liquid level. The average liquid level i s stored in final m emory every 15 m inutes. 5.1 CR1000 Example 'CRBasic code for CR1000, CR800, or C R850 Public WtrLvl ...

  • Campbell Manufacturing DB1 - page 11

    DB1 Liquid Level Measurement Sensor C a s e 3 P o r t S e t ( 3 , 1 ) 'Open valve to atmosphere EndSelect Delay(0,150,MSEC) S u m = 0 For j = 1 To 25 'Take 25 pressure readings for each tube and atmosphere BrFull(m V, 1, mV25,4, VX1, 1, 2500, true, true, 0, _60Hz, 1, 0) Su m = Su m + mV N e x t j Valve(i)= Sum/25 'Average the 25 read ...

  • Campbell Manufacturing DB1 - page 12

    DB1 Liquid Level Measurement Sensor 3: Excitation with Delay (P22 ) 1: 1 EX Chan 2: 0 Delay w/EX (units=.01sec) 3: 150 Delay after EX (unit s=.01sec) 4: 0 mV Excit ation Subroutine 1 measures the pressure in the tubing connected t o the second value: 4: Do (P86) 1: 1 Call Subrouti ne 1 5: Do (P86) 1: 52 Set low Port 2 The following instruct ions co ...

  • Campbell Manufacturing DB1 - page 13

    DB1 Liquid Level Measurement Sensor 2: Z=F (P30) 1: 0 F 2: 0 Exponent of 10 3: 7 Z Loc [:SUM ] 3: Beginning of Loop (P87) 1: 0 Delay 2: 25 Loop Count 4: Full Bridge (P6) 1: 1 Rep 2: 23 25 mV 60 Hz reject ion Range 3: 1 IN Chan 4: 1 Excite all reps w/EXchan 1 5: 2500 mV Excitation 6: 6 Loc [:mV/V ] 7: 1 Mult 8: 0 Offset 5: Z=X+Y (P33) 1: 7 X Loc SUM ...

  • Campbell Manufacturing DB1 - page 14

    DB1 Liquid Level Measurement Sensor 13: Do (P86) 1: 1 Call Subrouti ne 1 14: Z=X (P31) 1: 8 X Loc AVG LEVEL 2: 9-- Z Loc [:m V/V #1 ] 15: Do (P86) 1: 51-- Set low Port 1 16: End (P95) 17: Z=X-Y (P35) 1: 10 X Loc mV/ V #2 2: 9 Y Loc mV/V #1 3: 12 Z Loc [:DELTA V ] Note: On the next command, enter the measured Del ta h value for F, using the units (e ...

  • Campbell Manufacturing DB1 - page 15

    DB1 Liquid Level Measurement Sensor 6.1 Periodic Maintenance • Inspect submerged bubbler t ubes for sediment or ot her debris. Remove debris and clean tubes as required. • Replace submerged bubbler tubes if cracked or dama ged. • Replace nitrogen bottle every 2 to 3 months dependi ng on bubble rate. • Inspect valves for leaks every 2 to 3 m ...

  • Campbell Manufacturing DB1 - page 16

    DB1 Liquid Level Measurement Sensor 12 7. Replacement Parts Part # Description Qty. in DB1 5199 SWAK THREAD SEALANT 1 7397 TUBE FITTING ELL 1/4 O.D.x 1/8NPT 4 7558 NEEDLE VALVE ASSEMBLY 2 7561 2-WAY NC SOLENOID VALVE 3 7571 PLUG PIPE 1/8NPT TEFCOAT 2 6078 MOUNTING SCREW (6/32 x 2.00in) 4 7596 DB1 MANIFOLD BLOCK 1 7680 TUBE CUTTER 1 7667 RELAY CABLE ...

  • Campbell Manufacturing DB1 - page 17

    This is a bl ank page . ...

  • Campbell Manufacturing DB1 - page 18

    Campbell Scientific Companies Campbell Scientific, Inc. (CSI) 815 West 1800 Nort h Logan, Utah 84 321 UNITED STATES www.campbellsci.com info@campbellsci.com Campbell Scientific Afri ca Pty. Lt d. (CSAf) PO Box 2450 Somerset West 7129 SOUTH AFRICA www.csafrica.co.za cleroux@csafrica.co.za Campbell Scientific Aust ralia Pty. Ltd. (CSA) PO Box 444 Thu ...

Fabbricante Campbell Manufacturing Categoria Stud Sensor

I documenti che otteniamo dal fabbricante del dispositivoCampbell Manufacturing DB1 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Campbell Manufacturing
- manuali per l’uso DB1
- schede prodotto Campbell Manufacturing
- opuscoli
- o etichette energetiche Campbell Manufacturing DB1
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Campbell Manufacturing DB1.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Campbell Manufacturing DB1, manuali di manutenzione, brevi manuali o manuali utente Campbell Manufacturing DB1. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Campbell Manufacturing DB1.

Manuale completo del dispositivo Campbell Manufacturing DB1, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Campbell Manufacturing DB1 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Campbell Manufacturing DB1.

Il manuale per l’uso completo Campbell Manufacturing, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Campbell Manufacturing DB1 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Campbell Manufacturing DB1, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Campbell Manufacturing DB1 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Campbell Manufacturing DB1 - che ci dovrebbe aiutare nei primi passi durante l'uso Campbell Manufacturing DB1
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Campbell Manufacturing DB1
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Campbell Manufacturing DB1 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Campbell Manufacturing DB1?

Utilizza il modulo sottostante

Se non hai risolto il problema con Campbell Manufacturing DB1 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Campbell Manufacturing DB1 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)