    Operation/Reference Guide Custom Panel I nterfaces AXP-CPI16 16-Channel Custom Panel Interface Last Rev ised: 1/13/ 2009 ...

  • AMX AXP-CPI16 - page 2

    AMX Limited Warr anty and Disclaimer AMX warrant s it s pro ducts to be free of defect s in materia l and wor kmanshi p under n ormal use for three (3) years from the date of purc hase from AMX, with the follo wing ex cepti ons: • Electrol umine scent and LCD Contro l Panels a re wa rranted f or three (3) year s, excep t for the disp lay an d tou ...

  • AMX AXP-CPI16 - page 3

    Table of Contents i AXP-CPI16 16-Channel Custom Panel Interface Table of Contents Product I nformation ....... .......... ..... ....... ......... ..... ........ ......... ..... ....... .......... ..... .... 1 Specifications ... ............................. .................... .................... .................... ................ 1 Installat ...

  • AMX AXP-CPI16 - page 4

    ...

  • AMX AXP-CPI16 - page 5

    Produc t Info rma tion 1 A XP-CPI16 16-Channel Custom Panel Interface Product Information The AMX AXP-CPI16 16 Channel Custom Panel Interface Board (FIG. 1) simplifies the process of creating custom control panels for Axcess systems. Providing contact closure inputs and feedback outpu ts for up to 16 butto ns, the mini atu re PC boa rd co nta ins a ...

  • AMX AXP-CPI16 - page 6

    2 AXP-CPI16 16-Channel Custom Panel Interfa ce AXP-CPI16 Specificati ons (Cont.) AXlink S tatus LED Indicates AXlink c ommunication status as follows: • One blink per second communication is functioning. • T wo blinks per second devices specified in the master progr am do not mat ch the specified devices found. • Three blinks per sec ond indi ...

  • AMX AXP-CPI16 - page 7

    3 A XP-CPI16 16-Channel Custom Panel Interface Installation Mounting Dimensions FIG. 1 AXP-CPI16 mounting dimensions Mounting Dimensions Item Inch mm Item Description A 0.10 2.50 K P2 20-Pin Header .025 inch (6 mm) square pins, .1 inch (2.4 mm) typical spacing B 1.75 44.50 L 0.125 Inch (3.2 mm) mounting holes f or #4-40 (3 m m) sc rews C 1.55 39. 4 ...

  • AMX AXP-CPI16 - page 8

    4 AXP-CPI16 16-Channel Custom Panel Interfa ce Setting the AXlink Device Number The 8-position dev ice DIP switch defines th e AXP-CPI16 as an AXlink de vice. It can be one of 255 de v ices in the Axcess Control System. Set the de vice number with the total value of all O N (down) positions. As an e xample, the dev ice DIP switch sho w n belo w def ...

  • AMX AXP-CPI16 - page 9

    5 A XP-CPI16 16-Channel Custom Panel Interface Switch Wiring Diagrams FIG. 2 diagram s LED and Switch w iring. Connecting the AXlink Wiring T o install the AXlink data/power b us wiring . 1. Strip 0.25 inch of f the wire insulation for all four wires. If the wire is 20 A WG or less, fold the exposed wire o ver to obtain a positiv e connection. 2. I ...

  • AMX AXP-CPI16 - page 10

    ...

  • AMX AXP-CPI16 - page 11

    Progra mming 7 A XP-CPI16 16-Channel Custom Panel Interface Programming Use the same Axcess commands as with other AXlink control panels, such as the AXU-MSP series mini-softwire panels. When using the AXP-CPI16 as a control device, use On, Off, and Pulse co mmands to control sources connected to outputs and Push and Release co m mands to receiv e ...

  • AMX AXP-CPI16 - page 12

    8 AXP-CPI16 16-Channel Custom Panel Interfa ce Testing the Unit If you hav e p rogrammed the Axcess software, load the program into a PC connected to the control system Ma ster port. See Prog ramming on page 4. 1. Push switches connected to the AXP-CPI16. 2. Look at th e lower left of the Axcess screen to verify that the correct d ev ice and ch ann ...

  • AMX AXP-CPI16 - page 13

    AXP-CPI16 System Worksheet 9 A XP-CPI16 16-Channel Custom Panel Interface AXP-CPI16 System Worksheet Deale r ID Date Deale r PO Numb er J ob SO Numb er Descript ion Serial N umbe r Re v Number Device Numb er 4 3 2 1 15 16 4 3 14 2 13 1 6 5 18 6 17 5 8 7 20 8 19 7 Out In Out In Out In Out In Out In Out In Out In Out In +12 VDC PWR GND N/C N/C 12 10 ...

  • AMX AXP-CPI16 - page 14

    10 AXP-CPI16 16-Channel Custom Panel Interfa ce 12 11 10 9 15 16 4 3 14 2 13 1 14 13 18 6 17 5 16 15 20 8 19 7 Out In Out In Out In Out In Out In Out In Out In Out In +12 VDC PWR GND N/C N/C 12 10 11 9 Channel Pin Number 20-PIN HEADER HEAD ER P3 FUNCTION Pin Number Out In Out In Out In Out In Out In Out In Out In Out In N/C N/C +12 VDC PW R GND ...

  • AMX AXP-CPI16 - page 15

    ...

  • AMX AXP-CPI16 - page 16

    1/09 © 2 009 AMX. All right s reserved. AMX and the AMX log o are regist ered tradema rks of AMX . AMX reser ves the right t o alter sp ecific ations without notice at any time. It’s Y ou r W orld - T ak e Co ntr ol™ 3000 RESEARCH DR IVE, RICHARDSON, TX 75082 USA • 800.222.0193 • 469.624.8000 • 469-624-7153 fax • 800.932.6993 technical ...

Fabbricante AMX Categoria Network Card

I documenti che otteniamo dal fabbricante del dispositivoAMX AXP-CPI16 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici AMX
- manuali per l’uso AXP-CPI16
- schede prodotto AMX
- opuscoli
- o etichette energetiche AMX AXP-CPI16
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso AMX AXP-CPI16.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione AMX AXP-CPI16, manuali di manutenzione, brevi manuali o manuali utente AMX AXP-CPI16. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto AMX AXP-CPI16.

Manuali per l’uso simili

Manuale completo del dispositivo AMX AXP-CPI16, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare AMX AXP-CPI16 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti AMX AXP-CPI16.

Il manuale per l’uso completo AMX, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale AMX AXP-CPI16 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice AMX AXP-CPI16, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per AMX AXP-CPI16 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo AMX AXP-CPI16 - che ci dovrebbe aiutare nei primi passi durante l'uso AMX AXP-CPI16
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del AMX AXP-CPI16
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio AMX AXP-CPI16 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su AMX AXP-CPI16?

Utilizza il modulo sottostante

Se non hai risolto il problema con AMX AXP-CPI16 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con AMX AXP-CPI16 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)