Manuale per l’uso Vermont Casting VCS3505

31 pagine 2.85 mb
Scarica

Vai alla pagina of 31

Summary
  • Vermont Casting VCS3505 - page 1

    50002972 7 /05 Rev . 5 En USER’S MANU AL f o r Gas Barbecue Grill M o d el s VCS3505, V C S 3 5 0 5 B I , VCS4005, VCS5005/5010, VCS5005BI, VCS6005 CERTIFIED D E S I G N C E R T I F I E D n w o h S l e d o M 5 0 0 5 CS V ...

  • Vermont Casting VCS3505 - page 2

    Page i FOR YOUR SAFETY If y ou smell gas: • Shut off gas to the appliance; • Extinguish any open flame; • Open lid; • If odor continues, immediately call y our gas supplier or fire department. FOR Y OUR SAFETY Do not store or use gasoline or other flammable v apors and liquids in the vicinity of this or any other appliance. An LP cylinde ...

  • Vermont Casting VCS3505 - page 3

    SIGNAL WORDS: The Signal W ords used in this Manual, and their intended meanings, are as follows : D ANGER : Indicates that a failure to observe the safety instructions could result in death or cata- strophic bodily injury . W ARNING: Indicates that a failure to observe the safety instructions could result in serious bodily injury . CA UTION: Indic ...

  • Vermont Casting VCS3505 - page 4

    A. SAFE LOCA TIONS FOR USE OF THIS OUTDOOR GRILL D ANGER: • Never use this outdoor Grill inside any building, garage, shed or breezeway , or inside any boat, trailer or recreational vehicle, to prevent a possible fire and to prevent the possibility of carbon monoxide poisoning or asphyxiation. W ARNINGS: • Always confirm that this Grill is no ...

  • Vermont Casting VCS3505 - page 5

    B. SAFE USE OF LP (PR OP ANE) GAS D ANGER: • Never install a propane cylinder that is more than 80 % full, as the contents may lack adequate room for expansion when exposed to heat. Propane vapor may then be vented through the pres- sure release valve, which could accumulate in a pool and later result in a fire or explosion. Always instruct your ...

  • Vermont Casting VCS3505 - page 6

    • Always promptly shut off the gas supply and immediately extinguish all flames if you smell gas. Always seek assistance from your gas supplier or local Fire Department if the gas smell persists, because of the danger of fire or explosion. • Always confirm that there are no gas leaks before lighting this Grill. Apply a 50/50 solution of liqu ...

  • Vermont Casting VCS3505 - page 7

    Safety Important W arnings ..................................................... i - v Clearance Requirements ................................................. ii T able of Contents ............................................................ 1 Fuels ................................................................................. 2 Safety ........ ...

  • Vermont Casting VCS3505 - page 8

    FUELS W ARNING: Never use Natur al Gas in a Grill that has been configured to burn Propane Gas, and never use Propane Gas in a Grill that has been configured to use Natural Gas, to avoid possible bodily injury . Always consult the Rating Label on the back of your Grill to confirm which fuel must be used with the Grill. W ARNING: Use only the pre ...

  • Vermont Casting VCS3505 - page 9

    D ANGER: a) Do not store a spare LP - Gas Cylinder under or near this appliance b) Never fill the cylinder beyond 80% full; and c) If the information in a) and b) is not followed exactly , a fire causing death or serious injury may oc - cur . W ARNING: Always confirm that the openings in the cylinder compartment of the Grill are free of any obst ...

  • Vermont Casting VCS3505 - page 10

    Hooking Up to the LP (Propane) Gas Supply FOR Y OUR SAFETY 1. W ARNING: Never store or use gasoline or any other volatile substance in the vicinity of this Grill. 2. W ARN IN G: N ev er sto re a spa re pro pan e cyl in der in the vicinit y of thi s Grill, or in the vi cini ty of an y other potential heat source. LP (PR OP ANE) GAS SUPPL Y CONNECTIO ...

  • Vermont Casting VCS3505 - page 11

    Natural Gas Supply Connection TO CONNECT : 1. Push back the Sleeve on the Socket as shown below (see Fig. 6a). 2. Insert Plug and release the Sleeve (see Fig. 6b). 3. Push the Plug until Sleeve snaps forward to lock the Plug in the Socket. • W ARNING: Always conduc t the following safety test s before lighting the Grill, to prevent a possible fi ...

  • Vermont Casting VCS3505 - page 12

    Control Fu nctions PR OP ANE T ANK V AL VE W ARNING: Never open the T ank V alve unless the Grill is being prepared for use, to prevent the pooling of propane vapor . Always open the V alve immediately before lighting the Grill, and always close it immediately after cooking has been completed. BURNER CONTR OL V AL VES (see Fig. 7) On Model VCS3505, ...

  • Vermont Casting VCS3505 - page 13

    Lighting the Main Burners 1. Always open the Hood completely and always inspect the Grill and burners to confirm that all components are properly positioned before lighting the main burn- ers. W ARNING: Never stand with your head directly over the Grill when preparing to light the main burners, to prevent possible bodily injury . 2. Always confir ...

  • Vermont Casting VCS3505 - page 14

    T urning the Burners Off 1. Always turn the burner control knob(s) to the OFF position when cooking has been completed. 2. Promptly turn OFF the gas supply valve at the propane cylinder or at the main natural gas supply line. 3. Close the Hood of the Grill. FLARE-UPS “Flare-ups” sometimes occur when food drippings fall onto the hot sear plates ...

  • Vermont Casting VCS3505 - page 15

    Lighting the Rotisserie Burner (if applicable) The Rotisserie burner provides the stead y , even heat required to cook poultry and roasts to self-basted per - fection. Please read Assembly Procedures for instructions as well. TO ST AR T THE RO TISSERIE BURNER: 1. Always open the Hood completely before attempting to light the Grill. • W ARNING: Ne ...

  • Vermont Casting VCS3505 - page 16

    Ro t isser ie Setup ( i f applicab le ) The Rotisser ie bur ner is intended to be use d fo r rotisser ie cooki ng only . W A R NI NG : Nev er use the ma in bu r ners whi le using the Rotisser ie bur ner , as that could result in igniti ng the d r ipping s, or o verheating yo ur G r ill. T he Rot i ss er i e a s se mbly i nclud es a cou nte r weight ...

  • Vermont Casting VCS3505 - page 17

    Operation Page 1 1 Fig. 13 Control knob Igniter Lighting the Side Burner (if applicable) W ARNING: Never stand with your head directly over the Grill when preparing to light the side burner , to prevent possible bodily injury . 1. Turn the side burner control knob to HIGH (see Fig. 13). 2a. PIEZO IGNITION SYSTEM - T urn the Igniter Knob clockwise u ...

  • Vermont Casting VCS3505 - page 18

    Methods of Cooking W ith its combination of burners and accessories your gas grill can provide for virtually every conceivable style of cooking. • The powerful Main b urners deliver the middle and high range of tempera - tures desired for traditional barbecuing. This includes searing and finish- ing steaks, hamburgers, pork chops and the like, o ...

  • Vermont Casting VCS3505 - page 19

    One of the keys to extending your range of grilling capabilities is a fundamental understanding of the two common methods of cooking, Direct and Indir ect cooking. In the Direct cooking method , food is placed directly above the heat source. This method is used in searing for example where you require high and immediate heat to quickly brown the ou ...

  • Vermont Casting VCS3505 - page 20

    Grilling Tips: A few helpful hints will ensure that your grilling results are perfect every time. • Apply a light coating of cooking oil to your cooking grids before grilling, to prevent foods from sticking. • Cook similar portion sizes together , so that they all cook evenly . • Use tongs to turn foods on the Grill. • Never pierce foods wh ...

  • Vermont Casting VCS3505 - page 21

    T ype of Food Beef Burgers Roasts Blade, Sirloin T ip Steaks Porterhouse, Rib, Ribeye, Sirloin, T -Bone Filet Mignon Poultry Chicken, Parts Chicken, Whole Chicken Breasts, Boneless Cornish Hens Duck T urkey W eight/ Thickness 1 inch 1 inch 2 inches 3–4 lb. 1–2 lb. 1–1 1 / 2 lb. 4–5 lb. 13–25 lb. Cooking Time Rare: 4–7 min. Medium: 7–1 ...

  • Vermont Casting VCS3505 - page 22

    Cooking T emperature 400–450 ° F . 400–450 ° F . 325–350 ° F . 325–350 ° F . 325–350 ° F . 325–350 ° F . 375–400 ° F . 325–350 ° F . 400–450 ° F . 325–350 ° F . 325–350 ° F . T ype of Food Pork Chops Ham Steak Whole ham Ribs Back, Side Roasts Butt, Loin, Shoul- der T enderloin Sausage Lamb Chops Loin, Rib, Shoul- de ...

  • Vermont Casting VCS3505 - page 23

    Cooking T emperature 325–350 ° F . 325–350 ° F . 325–350 ° F . 325–350 ° F . 325–350 ° F . 325–350 ° F . 325–350 ° F . 400–450 ° F . 325–350 ° F . 325–350 ° F . 325–350 ° F . 325–350 ° F . T ype of Food V egetables Asparagus Beans Carrots Corn on the Cob Eggplant Mushrooms Onions Peppers Potatoes Roasted Garlic T ...

  • Vermont Casting VCS3505 - page 24

    Care & Cleaning W ARNING: Always observe the following safety precautions, to prevent bodily injury and to assure that your Grill will operate properly : CA UTION : Always allow sufficient time for the Grill to cool fully before handling or cleaning any of its parts. BURNERS: NO TE: All of the burner s shoul d be inspec ted frequently and clea ...

  • Vermont Casting VCS3505 - page 25

    • Cooking Grids The cooking grids have been porcelain enam- eled for durability and ease of cleaning. These Grills may be cleaned with any nonabrasive cleaning agent formulated for kitchen use, or a brass wire brush. NOTE: Always handle the grids with care, as porcelain enamel is susceptible to chipping. • Rotisserie Burner (if applicable) Insp ...

  • Vermont Casting VCS3505 - page 26

    DRIP TRA Y Th e dr ip t ra y an d gr ea se c up , lo cat ed u nd er the burner pan in the bottom of the Grill body are provided to catch excess cooking fats and juices. The drip tray is accessible from the rear of the Grill. It is necessary to lift up the pan slightly while pulling it out (see Fig. 19). Check it for accumulations in the grease cup ...

  • Vermont Casting VCS3505 - page 27

    Maintenance BURNER ADJUSTMENT NO TE: It may be necessary to adjust the burners periodically , to compensate for variables in gas char - acteristics. If you notice that the burner flame pattern is irregular (see Figs. 9a, 9b & 9c), it may be necessary to adjust the air shutter opening at the front of the venturi tubes. • The shutters are acce ...

  • Vermont Casting VCS3505 - page 28

    Unit won’t stay lit W ind Running out of fuel PROBLEM POTENTIAL CAUSE ACTION REQUIRED Burner will not light Gas supply turned off Out of propane Blockage in the gas system Misalignment of the gas valve to the venturi tubes of the burner . Improper attachment of the propane hose and regulator Control knob left open at startup, or turning gas on to ...

  • Vermont Casting VCS3505 - page 29

    Blockage in the burner or gas system Corroded burner Improper air shutter opening Excessively fatty foods Grease buildup Uneven burn pattern or Flashback fire Excessive yellow flame Flare-up Electrode fouled Electrode improperly gapped Electrode cracked Lead wire is discon- nected Lead wire is cracked Battery dead or installed wrong Igniter does ...

  • Vermont Casting VCS3505 - page 30

    Lifetime W arranty • On all exterior Stainless Steel Components, such as the cart paneling & doors, shelving, condiment bins and handles, if so equipped. • On all castings (1 year on paint). 10 Y ear W arranty • On all porcelain on steel surfaces such as the hood and burn chamber . • On all burners except side burner . 5 Y ear W arranty ...

  • Vermont Casting VCS3505 - page 31

    CFM Corporation 2695 Meado wv ale Boulev ard Mississaug a, Ontario L5N 8A3 Canada (800) 668-5323 www .cfmcorp .com Service Note: If you are experiencing difficultie s or are dissatisfied with your purchase, please contact CFM at the telephone number listed above prior to returning your grill to the store. ...

Fabbricante Vermont Casting Categoria Gas Grill

I documenti che otteniamo dal fabbricante del dispositivoVermont Casting VCS3505 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Vermont Casting
- manuali per l’uso VCS3505
- schede prodotto Vermont Casting
- opuscoli
- o etichette energetiche Vermont Casting VCS3505
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Vermont Casting VCS3505.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Vermont Casting VCS3505, manuali di manutenzione, brevi manuali o manuali utente Vermont Casting VCS3505. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Vermont Casting VCS3505.

Manuale completo del dispositivo Vermont Casting VCS3505, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Vermont Casting VCS3505 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Vermont Casting VCS3505.

Il manuale per l’uso completo Vermont Casting, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Vermont Casting VCS3505 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Vermont Casting VCS3505, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Vermont Casting VCS3505 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Vermont Casting VCS3505 - che ci dovrebbe aiutare nei primi passi durante l'uso Vermont Casting VCS3505
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Vermont Casting VCS3505
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Vermont Casting VCS3505 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Vermont Casting VCS3505?

Utilizza il modulo sottostante

Se non hai risolto il problema con Vermont Casting VCS3505 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Vermont Casting VCS3505 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)