Manuale per l’uso Vermont Casting 1610CE

28 pagine 5.08 mb
Scarica

Vai alla pagina of 28

Summary
  • Vermont Casting 1610CE - page 1

    Homeowner ’ s Installation and Operating Manual For use in Europe Do Not Discard This Manual: Retain for Future Use 30003846 4/08 Rev . 1 SAFETY NOTICE: IF THIS APPLIANCE IS NOT PROPERL Y INST ALLED, OPERA TED AND MAINT AINED, A HOUSE FIRE MA Y RESUL T . TO REDUCE THE RISK OF FIRE, FOLLOW THE INST ALLA TION INSTRUCTIONS. F AILURE TO FOLLOW INSTRU ...

  • Vermont Casting 1610CE - page 2

    2 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 This manual describes the installation, operation, and maintenance of the V ermont Castings Defiant Model 1610CE non-catalytic wood burning heater . This heater meets the U.S. Environmental Protection Agency’s emission limits for wood heaters sold on or after July 1, 1990. Under speci? ...

  • Vermont Casting 1610CE - page 3

    3 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 T able of Contents Specifications ................................................. 4 Installation ...................................................... 5 Assembly ...................................................... 12 Operation ...................................................... ...

  • Vermont Casting 1610CE - page 4

    4 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 Specifications Defiant, Model 1610CE Nominal heat output ............. 14.5 kW (49,500 BTU/hr) 1 Mnimum flue draught ....................... 12 Pa (0.048” WG) Mean flue gas temp .............................. 419° C (786° F) Efficiency (space heating) ............................ ...

  • Vermont Casting 1610CE - page 5

    5 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 Installation SAFETY NOTICE: IF YOUR DEFIANT IS NOT PROP- ERL Y INST ALLED, A HOUSE FIRE MA Y RESUL T . TO REDUCE THE RISK OF FIRE, FOLLOW THE INST ALLA TION INSTRUCTIONS. CONT ACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRIC- TIONS AND INST ALLA TION INSPECTION REQUIRE- MENTS IN YOUR AR ...

  • Vermont Casting 1610CE - page 6

    6 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 What Kind of Chimney to Use Y ou must connect the Defiant to a code-approved masonry chimney with a flue liner , to a relined masonry chimney that meets local codes, or to a prefabricated metal chimney . Figure 3 illustrates the two types. The chimney and chimney connector must be in go ...

  • Vermont Casting 1610CE - page 7

    7 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 c) Mild steel fluepipes complying with BS 1449: Part 1: 1991, with a flue wall thickness of at least 3 mm; d) Cast iron fluepipes complying with BS 41: 1973 (1998). Flue Pipes with a spigot and socket joint should be fitted with the socket facing upwards, to contain con- densates and ...

  • Vermont Casting 1610CE - page 8

    8 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 securely in place. Most chimney breeches incorporate thimbles, but the fit must be snug and the joint between the thimble and the chimney wall must be cemented firmly . A special piece called the “thimble sleeve,” slightly smaller in diameter than standard connectors and most thimbl ...

  • Vermont Casting 1610CE - page 9

    9 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 Through the Fireplace If your fireplace opening height is at least 737 mm (29"), you may install a Defiant through the opening using a “positive connection” kit, available from your local deal- er . Positive connection kits ensure a tight fit between the stove flue collar and ...

  • Vermont Casting 1610CE - page 10

    10 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 Costructional Hearth Dimensions as below At least 300 mm At least 150 mm or to a suitable heat resistant wall At least 150 mm Hearth Surface Free of Com- bustible Material Perimeter should be clearly marked e.g. edge of superimposed hearth Perimeter should be clearly marked e.g. edge of ...

  • Vermont Casting 1610CE - page 11

    1 1 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 Summary of Clearances Minimum recommended side clearances to non- combustible surfaces 125 mm (5”). Minimum recommended rear clearance to noncom- bustible surfaces 50 mm (2”). NOTE: The minimum thickness of solid noncombus- tible materials is specified in section 2 of Document ‘J ...

  • Vermont Casting 1610CE - page 12

    12 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 Set Up Y our Stove Cast iron stoves are heavy , and it will take two to four people to move your Defiant into position. Wipe the protective coating of oil from the griddle with a clean dry rag or a paper towel. Install the handle on the griddle. Slip the bolt through a washer , a nylon ...

  • Vermont Casting 1610CE - page 13

    13 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 Install the Optional Ash Door Heat Shield Many installations will require the use of the supplied ash door heat shield. Refer to the “Floor Protection” sections starting on Page 9 to determine if your installa- tion requires the use of the ash door heat shield. 1. Remove the two Phil ...

  • Vermont Casting 1610CE - page 14

    14 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 The Defiant Controls T wo controls regulate the performance of the Defiant: a primary air control supplies oxygen for the fire, and a damper directs air flow within the stove to activate and deactivate the catalytic combustor . (Fig. 25) Symbols cast into the stove are reminders of t ...

  • Vermont Casting 1610CE - page 15

    15 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 Defiant ST521 Intrepid loading 1 1/00 ST521 Fig. 28 T op loading is the best way to add fuel during regular use. Front loading is useful for kindling a fire. In addition, however , the front doors open as well for adding an occasional log to a fire. The Defiant NC is not approved for ...

  • Vermont Casting 1610CE - page 16

    16 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 agement information on Page 26 to see how the size, type, and location of your chimney will affect your stove operation. When thermometer readings drop below 175° C (350° F) it is time to adjust the air control for a higher burn rate or to reload the stove. A temperature reading over 3 ...

  • Vermont Casting 1610CE - page 17

    17 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 ST263 star ting a fire 12/99 ST263 Fig. 31 Start the fire with newspaper and dry kindling. ST264 good fire 12/99 ST264 Fig. 32 Add larger pieces of wood as the fire begins to burn well. 1. Open the stove bypass damper , and open the prima- ry air control fully . 2. Place se ...

  • Vermont Casting 1610CE - page 18

    18 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 operating temperature quickly . Use this sequence as a guide to successful refueling: NOTE: Door handles can be hot. A glove has been included with your stove. We recommend using this glove whenever operating door or damper controls and especially when operating the top griddle. 1. Open ...

  • Vermont Casting 1610CE - page 19

    19 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 Draft Management A stove is part of a system, which includes the chimney , the operator , the fuel, and the home. The other parts of the system will affect how well the stove works. When there is a good match between all the parts, the system works well. Wood stove or insert operation de ...

  • Vermont Casting 1610CE - page 20

    20 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 they must turn, it leaves some pipe in the room for heat transfer , and it gives you long-term flexibility for install- ing a different stove without relocating the thimble. There should be no more than eight feet of single-wall stove pipe between the stove and a chimney; longer runs ca ...

  • Vermont Casting 1610CE - page 21

    21 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 Below you will find important information on general care, inspection and maintenance of your V ermont Castings stove. Should it become necessary , use only replacement parts recommended by your authorized dealer . Keep Y our Stove Looking New and Working Its Best Let the fire in the s ...

  • Vermont Casting 1610CE - page 22

    22 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 Adjust the Damper as Needed The tension on the Defiant’s damper is adjustable to compensate for compression of the gasket that seals the damper to the upper fireback. T o adjust the damper: 1. Remove the griddle. Loosen the lock nut at the cen - ter of the damper . (Fig. 37) 2. Turn ...

  • Vermont Casting 1610CE - page 23

    23 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 3. Determine the correct length of the appropriate-sized gasket by laying it out in the channel. Allow an extra 25-51 mm (1-2”), and mark the spot to be cut. 4. Remove the gasket from the channel, place it on a wood cutting surface, and cut it at the marked spot with a utility knife. T ...

  • Vermont Casting 1610CE - page 24

    24 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 Clean the chimney connector by disconnecting the sec- tions, taking them outside, and removing any deposits with a stiff wire brush. Reinstall the connector sections after cleaning, being sure to secure the joints between individual sections with sheet metal screws. If you cannot inspect ...

  • Vermont Casting 1610CE - page 25

    25 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 12 87 24 23 20 22 19 21 13 14 5 16 17 18 25 69 64 35 65 6 7 8 39 32 88 42 43 50 41 15 48 38 40 34 2 53 54 55 58 76 75 70 74 68 80 78 67 77 75 71 73 80 78 68 33 2850 Defiant N parts 1 1/05 66 62 37 62 1 1 28 62 59 45 23 45 23 56 46 45 61 60 47 4 1 63 84 36 88 50 92 27 85 91 52 51 26 49 56 ...

  • Vermont Casting 1610CE - page 26

    26 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 Defiant W oodburning Stove Model 1610CE (continued) 1. Side Insulation 30002846 2. Right Side Brick 30002847 3. Left Side Refractory 30002848 4. Brick Support Bracket 30002480 5. Griddle Gasket 1203668 6. Back 30002833 7. Left Heat Deflector 30002442 8. Right Heat Deflector 30002441 9 ...

  • Vermont Casting 1610CE - page 27

    27 Defiant 1610CE Non-Catal ytic W oodbur ning Stove 30003846 Defiant W oodburning Stove Model 1610CE (continued) Shell Enamel Parts - Defiant Model 1610CE Part Name Classic Biscuit Bordeaux Chestnut Ebony Midnight V ermont Brown Blue Green T op 30002834 30002874 30002915 30002926 30002894 30002884 30002937 Left Side 30002832 30002872 30002913 30 ...

  • Vermont Casting 1610CE - page 28

    L I M I T E D L I F E T I M E W arranty For V ermont Castings Defiant, Non-Catalytic W ood Stove Limited Lifetime W arranty CFM Corporation warrants that all refractory brick and material used in this product will be warranted against deterioration not resulting from physical damage or overloading of the woodstove for the lifetime of this product. ...

Fabbricante Vermont Casting Categoria Stove

I documenti che otteniamo dal fabbricante del dispositivoVermont Casting 1610CE possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Vermont Casting
- manuali per l’uso 1610CE
- schede prodotto Vermont Casting
- opuscoli
- o etichette energetiche Vermont Casting 1610CE
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Vermont Casting 1610CE.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Vermont Casting 1610CE, manuali di manutenzione, brevi manuali o manuali utente Vermont Casting 1610CE. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Vermont Casting 1610CE.

Manuali per l’uso simili

Manuale completo del dispositivo Vermont Casting 1610CE, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Vermont Casting 1610CE dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Vermont Casting 1610CE.

Il manuale per l’uso completo Vermont Casting, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Vermont Casting 1610CE - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Vermont Casting 1610CE, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Vermont Casting 1610CE che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Vermont Casting 1610CE - che ci dovrebbe aiutare nei primi passi durante l'uso Vermont Casting 1610CE
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Vermont Casting 1610CE
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Vermont Casting 1610CE in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Vermont Casting 1610CE?

Utilizza il modulo sottostante

Se non hai risolto il problema con Vermont Casting 1610CE con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Vermont Casting 1610CE è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)