    38 T esla Irvine, CA 92618 Phone: (9 49) 679-8000 EZ Switch 10/100/1000 User Guide From SMC’ s EZ line of low-cost wo r kgroup LAN solutions April 2005 Pub. # 15000001720 0H R01 ...

  • SMC Networks SMCGS24 - page 4

    Infor mation furnished by SMC Netw orks, Inc . (SMC) is believ ed to be accurate and r eliable. Howev er, no res ponsibility is assumed by SMC for it s use, nor f or any infringements of patents or other right s of third parties which may result from its use. No li cense is g ranted by implication or ot herw ise under any pat ent or patent rights o ...

  • SMC Networks SMCGS24 - page 5

    i L IMITED W ARRANTY Limited W arranty Statem ent: SMC Networks , Inc. (“SMC”) warrants its products to be free from defects in workmanship and materials, under normal use and ser vice, for the applicable warranty ter m. All SMC products carr y a standard 90-day limited w a rr anty from the date of purchase from SMC or its A uthorized Re s elle ...

  • SMC Networks SMCGS24 - page 6

    L IMIT ED W AR RANTY ii WARRA NTI ES E X CLUS IVE: IF AN SMC PR ODUCT DOES NOT OPERA TE AS W ARRANTED ABO VE, CUSTOMER’ S SOLE REMED Y SHALL BE REP AIR OR REPLA CEMENT OF THE PR OD UCT IN QUES TION, A T SMC’S OPTION . THE FOREGOING W ARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER W ARRANTIES OR CONDITIONS , EXPRESS OR IMPLIED ...

  • SMC Networks SMCGS24 - page 7

    C OMPLIANCES iii C OMPLIANCES FCC - C lass A This equipment has been tested and found to comply with the limi ts for a C lass A digi tal device , pursuant to P art 15 of the FCC Rules . These limits are designed to provid e reasonable protection against harm ful interference in a residential installation. This equipment generates , uses and ca n ra ...

  • SMC Networks SMCGS24 - page 8

    C OMPLIANCES iv Industr y Canada - Class A This digital appar atus does not ex ceed the Class A l i mits for radio noise emissions from digi tal app aratus as set out in the interference- causing eq uipmen t stan dard en titl ed “Dig ital Apparatus, ” ICES-003 of the Department of Communications . Cet app areil numéri que resp ecte l es limit ...

  • SMC Networks SMCGS24 - page 9

    C OMPLIANCES v Ple ase read t he fol lowi ng sa fety info r mati on carefu lly before in stalling the Switch: WAR N I NG : Inst allation and removal of the unit must be car ried out by qualified personne l only . • This guide is intend ed for u se by netw ork a dminis trators w ho are responsible for setti ng up and installing ne twork equipmen t ...

  • SMC Networks SMCGS24 - page 10

    C OMPLIANCES vi F rance and Peru only This unit cannot be po wered from IT † supplies . If your supplies are of IT type, this unit must be powered by 230 V (2P +T) via an is olation transformer ratio 1:1, with the secondary con- nection point labelled Neutral, connected directly to earth (g round). † Impédance à la terre V euillez lire à fon ...

  • SMC Networks SMCGS24 - page 11

    C OMPLIANCES vii • Vous devez ra ccorder ce groupe à une sortie mise à la terre (mise à la masse) afin de respecter les normes inte rnationales de sécurité. • Le coupl eur d’ap pareil (le co nnecteur du groupe et non pas la prise murale ) doit resp ecter une conf iguration qui permet un bran chement sur une entrée d’ap pareil EN 60320 ...

  • SMC Networks SMCGS24 - page 12

    C OMPLIANCES viii Bitte unbedingt vor dem Einbauen des RPU d ie folgenden Sich erheitsanweisungen durchlesen: WAR N U NG : Die Installatio n und der Ausbau des G eräts darf nur durch Fachperson al er folg en. • Diese Anleitun g ist fr die Benutzung durch Netzwe rkadministratoren vorgese hen, die fr die Installatio n und das einstel len von Netzw ...

  • SMC Networks SMCGS24 - page 13

    C OMPLIANCES ix W ar nings an d Cautionar y Messa ges Wa r n i n g s (in German) Stromkabel . Dies muss von dem Land, i n dem es benutzt wird geprüft werden: Schweiz Dieser Stromst ecker muß die SEV/ASE 1011 Bestimmung en ein- halten. Europe Das Netzkabel muß vom Typ HO3VVF3GO.75 (Mindestan- forder ung) se in und die Aufsc hrift <HAR> o de ...

  • SMC Networks SMCGS24 - page 14

    C OMPLIANCES x En vironmental Statement The manufact urer of this product en deavours to susta in an environmen tally- friend ly policy throughout the ent ire produc tion proc ess. This is a chieved thou gh the fol lowing mean s: • Adherence to national legis lation and regulations on envi r onmental production standards . • Conservation of ope ...

  • SMC Networks SMCGS24 - page 15

    C OMPLIANCES xi Safety Compliance W a rn i ng : F ib e r Op t i c P o rt S af e t y A vertissment: P or ts pour fibres optiques - sécur ité sur le plan op tique W ar nhinweis: F aseroptikanschlüsse - Optische Sicherheit When using a fiber optic port, never look at the transmit laser while it is pow ered on. Also , never look dir ectly at the fib ...

  • SMC Networks SMCGS24 - page 16

    C OMPLIANCES xii ...

  • SMC Networks SMCGS24 - page 17

    vii T ABLE OF C ONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Features a nd Benefits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Front Panel RJ-45 P orts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Front Pan el LEDs . . . . ...

  • SMC Networks SMCGS24 - page 18

    viii ...

  • SMC Networks SMCGS24 - page 19

    F EATURES AND B ENEFITS 1 I NTRODUCTION The EZ Switch™ 10/100/1000, SM CGS16 and SMCGS24, are high-pe rfor mance Gigabit Et hernet switc hes designed for deliv ering Gigabit connectivity to the desktop . They provide 16/24 full-du plex 1000B ASE-T ports that significantly improv e network performance and boost th roughp ut for high-ban dwidth app ...

  • SMC Networks SMCGS24 - page 20

    I NTR ODU C TI ON 2 Front Panel RJ-45 Ports The EZ Switch 10/100/1000 features 16/24 1000B ASE-T po rts with RJ-45 connectors located on the front panel of th e switch. Because all por ts su ppor t a utom atic M DI/MD I-X ope rat ion, you ca n us e straigh t-throu gh cab les for all network conn ection s to PCs or ser vers, or to other switches or ...

  • SMC Networks SMCGS24 - page 21

    R EAR P ANEL 3 SMCGS16 SMCGS24 Rear Panel The A C po wer connec tor is loca ted on t he rear pane l of th e switch. ...

  • SMC Networks SMCGS24 - page 22

    I NS TAL LI NG THE S WITCH 4 I NSTALLING THE S WITCH Before installing the switch, verify that you ha ve all the items lis ted under “P ackage Contents. ” Note that the s witch can be installed on any suitabl y large flat surface or in a standard EIA 19-inch r ack. Package Conten ts The EZ Switch 10/100/1000 includes: Selecting a Site Be sure t ...

  • SMC Networks SMCGS24 - page 23

    I NSTRUCTIONS 5 • There should be adequate space (approximate ly two in ches) on all sides for prope r air fl ow. • Make sure twisted -pair cab le is always rou t ed away fr om power lines , fluoresce nt lighting fi xtures and ot her sources o f electrical i nterfer ence such as radios, trans mitters, etc. • Make sure that a prope rly grounde ...

  • SMC Networks SMCGS24 - page 24

    I NS TAL LI NG THE S WITCH 6 Note: If an a ttached device does no t supp or t auto-n eg otia tion, the data rate will be sens ed automatical ly and the communication mo de will default to half duplex. 4. Cascading Switches and Other N etwork Devices: All the ports on the sw itch suppo r t autom atic MDI /MDI-X configur ation for cab le connec tions ...

  • SMC Networks SMCGS24 - page 25

    I NSTRUCTIONS 7 A PPLICATION E XAMPLE A typical applic ation for the SMCGS16 is illustrated below . EZ Switch 10/100/1000 SMCGS16 Server SMC-EZ109DT Workstations LAN 1 PWR WLAN WA N 2 3 Link Activity Notebook Internet Notebook with SMC2835W Wireless PC Card SMC2804WBR Wireless Broadband Router Workstations With SMC9452TX Gigabit PCI Cards ...

  • SMC Networks SMCGS24 - page 26

    T R OUBLESHOOTING 8 T ROUBLESHOOTING Diagnosi ng Switch Indic ators 1. Symptom P ower LED d oes not lig ht afte r power on. Probable Causes • AC power c ord may be defec t ive. Po s s i b le S o l u t i o n s • Check for loo s e connect ions. • Check the power o utlet by using it for another device. • Repla ce the A C power cord. 2. Symptom ...

  • SMC Networks SMCGS24 - page 27

    C ABLE S PECIFICATIONS 9 C ABLES Cable Sp ecificatio ns 10BASE-T/100BASE-T X Pin Assignme nts Caution: DO NO T plu g a ph one jack co nnec tor into any RJ-45 p or t. Use only twisted-pair cab les with RJ-45 con n ectors t h at confor m with FC C standar ds . Use unshielde d twisted-pair (UTP) or shielded twis ted-pair (STP) cab le for RJ-45 connect ...

  • SMC Networks SMCGS24 - page 28

    C ABL ES 10 The table below shows the 10B ASE-T/100BASE-TX MDI-X and MDI por t pino uts. 1000BASE-T Pin Assignments The table below shows the 1000B ASE-T MD I and MDI-X port pinouts. Th ese po rt s requ ire th at all four pa irs of wires be co nnec ted. No te tha t for 1000B ASE-T operation, all four pairs of wires are used for both transmit and re ...

  • SMC Networks SMCGS24 - page 29

    1000 B ASE- T C ABL E R EQUIREMENTS 11 1000B A SE-T Ca ble Requirem ents All Catego ry 5 UTP cables that are used for 100B ASE-TX connections should also wo rk for 1000BASE-T , providing that all four wire pairs are connected. However , it is re commended that for all critic al connectio ns , or any new ca ble install ations , 4-pair Ca tegor y 5e ...

  • SMC Networks SMCGS24 - page 30

    P RO DU CT S PECIFICATIONS 12 P RODUCT S PECIFI CATIO NS EZ Swit ch 10/ 100/1 000 Standards Confor mance IEEE 802.3-2002 Ethernet, F ast Et hernet, Gigabit Ether net Full-duplex flow control Communication R ate 10, 100, and 1000 Mbps Communication Mode Full or half duplex at 10/100 Mbps Full duplex at 1000 Mbps Media Suppor ted 10B ASE-T : 100-o hm ...

  • SMC Networks SMCGS24 - page 31

    EZ S WITCH 10/1 00/1000 13 We i g h t SMCGS16: 2.0 kg (4.04 lbs) SMCGS24: 2.2 kg (4.85 lbs) MAC Address T able 8 K entries Memor y Buf fer SMCGS16: 272 Kbits on-chip frame buffer SMCGS24: 400 Kbits on-chip frame buffer P ower Consumption SMCGS16: 15.8 W atts SMCGS24: 24.2 W atts Heat Dissipation 130 BTU/hr maximum P ower R equir ement Input V oltag ...

  • SMC Networks SMCGS24 - page 32

    P RO DU CT S PECIFICATIONS 14 ...

  • SMC Networks SMCGS24 - page 33

    ...

  • SMC Networks SMCGS24 - page 34

    FOR TECHNIC AL SUPPOR T , C ALL: Fr om U.S.A. and Canada (24 hours a da y , 7 da y s a w eek) (800) SMC-4-Y OU; Phn: (949) 679-8000; F ax: (949) 679-1481 Fr om Europe : C ontac t details can b e found on www .smc.com INTERNET E-mail address: techsupp ort@smc.com Driv er upda tes: h ttp://www .smc .com/index.cfm?action=tech_support_driv ers_download ...

Fabbricante SMC Networks Categoria Switch

I documenti che otteniamo dal fabbricante del dispositivoSMC Networks SMCGS24 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici SMC Networks
- manuali per l’uso SMCGS24
- schede prodotto SMC Networks
- opuscoli
- o etichette energetiche SMC Networks SMCGS24
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso SMC Networks SMCGS24.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione SMC Networks SMCGS24, manuali di manutenzione, brevi manuali o manuali utente SMC Networks SMCGS24. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto SMC Networks SMCGS24.

Manuali per l’uso simili

Manuale completo del dispositivo SMC Networks SMCGS24, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare SMC Networks SMCGS24 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti SMC Networks SMCGS24.

Il manuale per l’uso completo SMC Networks, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale SMC Networks SMCGS24 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice SMC Networks SMCGS24, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per SMC Networks SMCGS24 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo SMC Networks SMCGS24 - che ci dovrebbe aiutare nei primi passi durante l'uso SMC Networks SMCGS24
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del SMC Networks SMCGS24
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio SMC Networks SMCGS24 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su SMC Networks SMCGS24?

Utilizza il modulo sottostante

Se non hai risolto il problema con SMC Networks SMCGS24 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con SMC Networks SMCGS24 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)