Manuale per l’uso Goodman Mfg ASPF

20 pagine 0.33 mb
Scarica

Vai alla pagina of 20

Summary
  • Goodman Mfg ASPF - page 1

    Goodman Manufacturing Company , L.P . 5151 San Felipe, Suite 500, Houston, TX 77056 www .goodmanmfg.com © 2004-2010 Goodman Manufacturing Company , L.P . C US ® A TUF/ARUF/ARPF/ADPF/ASPF IO-355E 08/10 RECOGNIZE THIS SYMBOL AS A SAFETY PRECAUTION. A TTENTION INST ALLING PERSONNEL Prior to installation, thoroughly familiarize yourself with this Ins ...

  • Goodman Mfg ASPF - page 2

    2 Import ant Safety Instructions The following symbols and labels are used throughout this manual to indicate immediate or potential safety hazards. It is the owner’s and installer’s responsibility to read and com- ply with all safety information and instructions accompanying these symbols. Failure to heed safety information increases the risk ...

  • Goodman Mfg ASPF - page 3

    3 T o pre ve n t t he r is k of pr op e rt y dam age , per s on al injury , o r death, do not store comb ustible m aterials or use gasoline or other flammab le liquids or vapo rs in the vi c i n ity o f th i s un it. CARBON MONOX IDE POISO NING HAZ AR D - Special W a rning for Instal la tio n of Fur nace or A i r Handling Units i n Encl os ed Areas ...

  • Goodman Mfg ASPF - page 4

    4 Pre-Inst allation Instructions Carefully read all instructions for the installation prior to in- stalling product. Make sure each step or procedure is under- stood and any special considerations are taken into account before starting installation. Assemble all tools, hardware and supplies needed to complete the installation. Some items may need t ...

  • Goodman Mfg ASPF - page 5

    5 3568 1 0 1 5 2 0 2 1 600 16 25 32 37 800 12 19 24 38 38 1000 10 15 19 22 30 46 1 2 0 0 8 1 31 61 92 53 85 15 6 1 4 0 0 7 1 11 41 62 23 34 34 8 1600 6 9 12 14 19 28 38 42 1800 5 8 11 12 17 25 34 37 2000 5 8 10 11 15 23 30 34 CFM HEAT KIT NOMIN AL kW Table 4 208/1/60 Supply Voltage - Temperature Rise Table °F NOTE: For installations not indicated ...

  • Goodman Mfg ASPF - page 6

    6 Maximum Overcurrent Protection (MOP) Every installation must include an NEC (USA) or CEC (Canada) approved overcurrent protection device. Also, check with local or state codes for any special regional re- quirements. Protection can be in the form of fusing or HACR style circuit breakers. The Series and Rating Plate can be used as a guide for sele ...

  • Goodman Mfg ASPF - page 7

    7 2. After the gas has escaped, remove the nut and discard the black or brass cap. 3. Remove the check piston to verify it is correct and then replace the piston. See piston kit chart in instructions. 4. Use a tube cutter to remove the spin closure on the suction line. 5. Remove the tailpiece clamped to the exterior and slide the 13/16 nut into pla ...

  • Goodman Mfg ASPF - page 8

    8 3” F L A T IN S ULA TI O N RET AI NER (BOTH SID ES) Figure 4 To complete the conversion, slide the evaporator coil into the chassis and attach the three (3) access panels. (Figure 5). WRA PPER INSU LA T ION JAC KET ZEE C OIL SUPPORT WRAPPER STI FF ENE R DRAIN P AN INSUL A TION KIT BLOWER A SSEMBL Y Figure 5 NOTE: When converted to downflow posi ...

  • Goodman Mfg ASPF - page 9

    9 drain line located inside the building. Use Armaflex® or similar material. A Secondary Condensate Drain Connection has been pro- vided for areas where the building codes require it. Pitch the drain line 1/4" per foot to provide free drainage. Insulate drain lines located inside the building to prevent sweating. Install a condensate trap to ...

  • Goodman Mfg ASPF - page 10

    10 0. 1" 0. 2" 0. 3" 0. 4" 0.5 " High 1155 1090 10 25 950 895 A RUF 172916 M ed. 94 0 890 860 81 5 755 Low 695 665 650 610 55 0 High 1155 1090 10 25 950 895 A RUF 182416 M ed. 94 0 890 860 81 5 755 Low 695 665 650 610 55 0 High 1135 1085 10 25 965 915 A RUF 193116 M ed. 86 0 825 780 75 0 680 Low 600 570 545 500 46 5 High 13 ...

  • Goodman Mfg ASPF - page 11

    11 thermostat as shown in Figures 10 and 11 . Goodman® part number CHT18-60 is a single-stage cool and single-stage heat thermostat. Goodman® part number HPT18-60 is a single-stage cool, two-stage heat pump thermostat. The first stage is heat pump heating and the second stage is optional electric heat. If additional features are desired, such as ...

  • Goodman Mfg ASPF - page 12

    12 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T AGE ! DIS CO NN E CT ALL P OWER BE FORE SERV ICI NG. MUL TI PLE PO WER S OURC ES MA Y B E PRES ENT . F AILUR E TO DO SO MA Y CAU SE PROP ERTY DAMA GE, PER SON AL I NJUR Y OR DEA TH . WA R N I N G ROOM T HERM OST A T WY GR #18 GA ...

  • Goodman Mfg ASPF - page 13

    13 HIGH VOL T AGE ! DIS CO NN E CT ALL P OWER BE FORE SERV ICI NG. MUL TI PLE PO WER S OURC ES MA Y B E PRES ENT . F AILUR E TO DO SO MA Y CAU SE PROP ERTY DAMA GE, PER SON AL I NJUR Y OR DEA TH . WA R N I N G Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. C W2 OYR YOC GR E W2 TYP ICAL H/ ...

  • Goodman Mfg ASPF - page 14

    14 ASPF THERMOST A T CONNECTIONS The following composite wiring diagrams detail various configurations in which the ASPF air handlers can be used. Ex- amples include single-stage cooling and heat pump with single or two-stage electric heating. All these configurations can be applied with convenient connections to outdoor thermostat applications. Th ...

  • Goodman Mfg ASPF - page 15

    15 HIGH VOL T AGE ! DIS CO NN E CT ALL P OWER BE FORE SERV ICI NG. MUL TI PLE PO WER S OURC ES MA Y B E PRES ENT . F AILUR E TO DO SO MA Y CAU SE PROP ERTY DAMA GE, PER SON AL I NJUR Y OR DEA TH . WA R N I N G Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. YG W W2 R COOLIN G UNIT WITH OPT ...

  • Goodman Mfg ASPF - page 16

    16 Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. HIGH VOL T AGE ! DIS CO NN E CT ALL P OWER BE FORE SERV ICI NG. MUL TI PLE PO WER S OURC ES MA Y B E PRES ENT . F AILUR E TO DO SO MA Y CAU SE PROP ERTY DAMA GE, PER SON AL I NJUR Y OR DEA TH . WA R N I N G G C R HEA T PUMP UNIT WITH OPTIO ...

  • Goodman Mfg ASPF - page 17

    17 HIGH VOL T AGE ! DIS CO NN E CT ALL P OWER BE FORE SERV ICI NG. MUL TI PLE PO WER S OURC ES MA Y B E PRES ENT . F AILUR E TO DO SO MA Y CAU SE PROP ERTY DAMA GE, PER SON AL I NJUR Y OR DEA TH . WA R N I N G Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring. 12 0/24 0 V AC TS T A T OP TI ON ...

  • Goodman Mfg ASPF - page 18

    18 THIS P AGE LEFT INTENTIONALL Y BLANK ...

  • Goodman Mfg ASPF - page 19

    19 THIS P AGE LEFT INTENTIONALL Y BLANK ...

  • Goodman Mfg ASPF - page 20

    20 Goodman Manufacturing Company , L.P . 5151 San Felipe, Suite 500, Houston, TX 77056 www .goodmanmfg.com © 2004-2010 Goodman Manufacturing Company , L.P . ...

Fabbricante Goodman Mfg Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoGoodman Mfg ASPF possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Goodman Mfg
- manuali per l’uso ASPF
- schede prodotto Goodman Mfg
- opuscoli
- o etichette energetiche Goodman Mfg ASPF
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Goodman Mfg ASPF.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Goodman Mfg ASPF, manuali di manutenzione, brevi manuali o manuali utente Goodman Mfg ASPF. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Goodman Mfg ASPF.

Manuali per l’uso simili

Manuale completo del dispositivo Goodman Mfg ASPF, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Goodman Mfg ASPF dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Goodman Mfg ASPF.

Il manuale per l’uso completo Goodman Mfg, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Goodman Mfg ASPF - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Goodman Mfg ASPF, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Goodman Mfg ASPF che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Goodman Mfg ASPF - che ci dovrebbe aiutare nei primi passi durante l'uso Goodman Mfg ASPF
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Goodman Mfg ASPF
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Goodman Mfg ASPF in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Goodman Mfg ASPF?

Utilizza il modulo sottostante

Se non hai risolto il problema con Goodman Mfg ASPF con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Goodman Mfg ASPF è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)