Manuale per l’uso Honeywell Manning EC-P2

17 pagine 0.19 mb
Scarica

Vai alla pagina of 17

Summary
  • Honeywell Manning EC-P2 - page 1

    Gas Sensor Manning EC-P2 Instruction and Installation Manual 07/09 Release G Draft Honeywell Confidential & Proprietary This work contains valuable, confide ntial, and proprietary information. Disclos ure, use or reproduction outside of Honey well Inc. is prohibited except as authoriz ed in writing. This unpublished work is protected b y the la ...

  • Honeywell Manning EC-P2 - page 2

    Notices and Trademarks Copyright 2009 by Honeyw ell International In c. Release G July 2009 While this infor mation is presented in go od faith and believed to be accurate, Ho neywell disclaims th e implied warranties of merchan tability and fitness for a partic ular purpose and makes no express warranties except as may be stated in its written agr ...

  • Honeywell Manning EC-P2 - page 3

    About This Document World Wide Web The following Hon eywell web sites may b e of interest. Honeywell Organization WWW Address (URL) Corporate www.honeywe ll.com Honeywel l Analyt ics www.honeywe llanalytic s.com Manning Gas Det ection www.manning systems.com Telephone Contact us by telephone at the n umbers listed b elow. Organization Phone Number ...

  • Honeywell Manning EC-P2 - page 4

    Contents Serial number: Section Title Page 1 System Description 5 2 Operation 7 3 Maintenance 9 4 Programming and Advan ced Features 11 5 Appendices 15 6 Limited Warranty 17 Introduction This manual has been prepared to h elp in the use of the Manning EC-P2 Portable Gas Det ector. ATTENTION: This manual must be ca refully followed by all individ ua ...

  • Honeywell Manning EC-P2 - page 5

    1 System Description Figure 1: Basic Parts of the Manning EC-P2 Sensor The Manning EC-P2 is a por table, battery opera ted instrument for the measur ement of gas concent rations in ambient air. Outlet T ube Sampling Wand Assembly Data Logger Port Standby Battery Recharge Receptacle Primary Batter y The Manning EC-P2 can be converted from on e targe ...

  • Honeywell Manning EC-P2 - page 6

    Manning EC-P2 Sensor 19546 ECP2 07/0 9 REVG Copyright © 200 9 Honeywell Analyt ics. All Rights Rese rved. 6 1 System Description continue d System Specific ations Primary P ower: Alkaline C cell battery, 4 8 hours operation. Note: An audible alarm sing le beep every 60 seconds indica tes that either the Alkaline C cell battery is low or the intern ...

  • Honeywell Manning EC-P2 - page 7

    2 Operation A Operating the Sensor Figure 2: Normal Operating Screen The Manning EC-P2 is shipp ed ready for use. To power up the instr ument, push the PWR butto n. The power up seq uence displa ys first the se lf check, the sensor full scale value , the downsc ale caution level, warning concentr ation setpoint, alarm concent ration setpoint, outp ...

  • Honeywell Manning EC-P2 - page 8

    2 Operation continued C Response Test CAUTION DO NOT BLOCK INLET OR OUTLIET PORTS INLET OUTLET TEST UNIT PRIOR TO USE Sensor (SMART -CELL) Filter Material Sensor alignment pin Sensor alignment groove Manifold lid Inlet fitting Sampling wand Outlet tube barb fitting Thumbscrews (loosen to remove manifold lid) Figure 3: Manifold Assembly Prior to use ...

  • Honeywell Manning EC-P2 - page 9

    3 Maintenance A Periodic Maintenance It is essential t hat the test an d calibration sched ule be adhered to. Hone ywell Analytics re commends the following maintenance s chedule: • Response test prior to each use. Expos e sensor to a sa mple of the tar get gas to ver ify proper sensor response and alar m functions. • Calibration should be perf ...

  • Honeywell Manning EC-P2 - page 10

    Calibration gas flowmeter Vent through flowmeter Bypass tee Calibration gas bottle (use only Certified Calibration Gas) 1.0 .8 .6 .4 .2 LPM AIR CAUTION DO NOT BLOCK INLET OR OUTLIET PORTS INLET OUTLET TEST UNIT PRIOR T O USE F u 3 Maintenance continued Zero Calibration 4 ) Be sure the unit is in clean air or ap ply zero air for two minutes. 5 ) Pus ...

  • Honeywell Manning EC-P2 - page 11

    4 Programming and Advanced Features A Alarm Setpoints, Functions The Manning EC-P2 ha s three adjust able alarm setpoints. These setpoints are s tored on each SMART-CELL. The Cautio n setpoint is to warn of excessive negative zero drift . The WARNING and ALARM setpoi nts are to warn of p otentially dangerous tar get gas concentrat ions. The f ollow ...

  • Honeywell Manning EC-P2 - page 12

    4 Programming and Advanced Features continued B Display Variables The Manning EC-P2 has t wo adjustable display variables. These variab les control sig nal conditioning of the LCD display. Variable s are stored on each SMART-CELL. The AVG (Average) variable determines the nu mber of one second samples to average to calculate the disp layed value. T ...

  • Honeywell Manning EC-P2 - page 13

    4 Programming and Advanced Features continued Programming sa mple mode varia bles: The sample mode variables are Sample, Measure and Clear as described above. The f ollowing procedure will change the Sample variab le. To Enter SAMP / MEAS / CLEAR Mode 1) Push power b utton to turn unit on. Wait for power up seq uence to finis h (30 seconds). 2) Pus ...

  • Honeywell Manning EC-P2 - page 14

    4 Programming and Advanced Features continued To Stop the Data Loggi ng Session 7) Push the MENU bu tton. 8) Push the LOG button. 9) Push and hold the STOP butt on until the screen changes to CLEAR / INT / START / MODE (two seconds). 10) Push the DONE button to get back into normal operation mod e. Working with the “EC-P2” program : The “EC-P ...

  • Honeywell Manning EC-P2 - page 15

    Manning EC-P2 Sensor 19546 ECP2 07/0 9 REVG Copyright © 200 9 Honeywell Analyt ics. All Rights Rese rved. 15 5 Appendices APPENDIX A: SMART-CELLs Available GAS RANGE PART NUMBER Alcohol 0-500 ppm EC-P2-SMART-CELL-OH-0/5 00ppm Ammonia 0-500 ppm EC-P2-SMART-CELL-NH 3 -0/500ppm Ammonia 0-2000 ppm EC-P2-SMART-CELL-NH 3 -0/2000ppm Bromine 0-5 ppm EC-P2 ...

  • Honeywell Manning EC-P2 - page 16

    5 Appendices continued APPENDIX B: SMART-CELL Cross-Sensi tivity Table (Interference Gases) Manning EC-P2 Sensor 19546 ECP2 07/0 9 REVG Copyright © 200 9 Honeywell Analyt ics. All Rights Rese rved. 16 SENSOR AND TARGET GAS B r 2 Cl 2 ClO 2 O 3 NH 3 CO H 2 O 2 NO H 2 S NO 2 SO 2 HCHO OH Fl 2 HCl H 2 O 2 Bromine ----- 1.0 1.0 0.7 -0.1 None None None ...

  • Honeywell Manning EC-P2 - page 17

    Manning EC-P2 Sensor 19546 ECP2 07/0 9 REVG Copyright © 200 9 Honeywell Analyt ics. All Rights Rese rved. 17 6 Limited Warranty 1. Limited Warranty Honeywell Analy tics, Inc. warrant s to the original purchaser and/or ultimat e customer (“Purchaser”) of M anning produc ts (“Product”) that if any part ther eof proves to be defective in mate ...

Fabbricante Honeywell Categoria Yogurt Maker

I documenti che otteniamo dal fabbricante del dispositivoHoneywell Manning EC-P2 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Honeywell
- manuali per l’uso Manning EC-P2
- schede prodotto Honeywell
- opuscoli
- o etichette energetiche Honeywell Manning EC-P2
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Honeywell Manning EC-P2.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Honeywell Manning EC-P2, manuali di manutenzione, brevi manuali o manuali utente Honeywell Manning EC-P2. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Honeywell Manning EC-P2.

Manuali per l’uso simili

Manuale completo del dispositivo Honeywell Manning EC-P2, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Honeywell Manning EC-P2 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Honeywell Manning EC-P2.

Il manuale per l’uso completo Honeywell, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Honeywell Manning EC-P2 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Honeywell Manning EC-P2, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Honeywell Manning EC-P2 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Honeywell Manning EC-P2 - che ci dovrebbe aiutare nei primi passi durante l'uso Honeywell Manning EC-P2
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Honeywell Manning EC-P2
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Honeywell Manning EC-P2 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Honeywell Manning EC-P2?

Utilizza il modulo sottostante

Se non hai risolto il problema con Honeywell Manning EC-P2 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Honeywell Manning EC-P2 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)