Manuale per l’uso Generac 5818

36 pagine 16.54 mb
Scarica

Vai alla pagina of 36

Summary
  • Generac 5818 - page 1

    EcoGen 6kW Generator Owner's Manual L I S T E D C U S  NOT INTENDED FOR USE IN CRITICAL LIFE SUPPORT APPLICA TIONS.  ONL Y QUALIFIED ELECTRICIANS OR CONTRACTORS SHOULD A TTEMPT INSTALLA TION!  DEADL Y EXHAUST FUMES! OUTDOOR INST ALLA TION ONL Y! ...

  • Generac 5818 - page 2

    Introduction .............................................. 1 Read This Manual Thoroughly ................................................1 Safety Rules ............................................. 1 Contents ...............................................................................1 Operation and Maintenance.................................. ...

  • Generac 5818 - page 3

    1 INTRODUCTION Thank you for purchasing this compact, high per for mance, air -cooled, engine-driven generator . It is designed to supply electrical power to operate an inver ter/batter y charger as a component in an off-grid power solution. This unit is factor y installed in an all-weather , metal enclosure and is intended exclusively for outdoor ...

  • Generac 5818 - page 4

    2 Study these SAFETY RULES carefully before installing, operating or ser vicing this equipment. Become familiar with this Owner’s Manual and with the unit. The generator can operate safely , effi- ciently and reliably only if it is properly installed, operated and maintained. Many accidents are caused by failing to follow simple and fundamental r ...

  • Generac 5818 - page 5

    3 The National Electrical Code (NEC) requires the frame and external • electrically conductive par ts of the generator to be connected to an approved ear th ground. Local electrical codes also may require proper grounding of the generator electrical system. Af ter installing this home standby electrical system, the genera- • tor may crank and s ...

  • Generac 5818 - page 6

    n Only qualified electricians or contractors should attempt such installations, which must comply strictly with applicable codes, stan- dards and regulations. 1.1 UNP ACKING/INSPECTION Af ter unpacking, carefully inspect the contents for damage. This standby generator set is ready for installation with a factor y • supplied and pre-mounted base p ...

  • Generac 5818 - page 7

    5 1.4 THE GENERA TOR Figure 1.1 – 6kW , V -twin, GT -530 Engine (door removed) Air Filter External Oil Fill/Dipstick Control Panel Data Lab el Circuit Breaker Fuel Inlet (back) Fue l Regulator Composite Base Battery Compartment Oil Filter Exhaust Enclosure Engine Oil Dipstick Engine Oil Fill Figure 1.2 – Data Label Sample 1.5 SPECIFICA TIONS 1. ...

  • Generac 5818 - page 8

    1.7 FUEL REQUIREMENTS AND RECOMMENDA TIONS This unit uses a LP vapor withdrawal system only . This type of system uses the vapors formed above the liquid fuel in the storage tank. Recommended fuels should have a Btu content of at least 2,520 Btus per cubic foot for LP gas. Ask the fuel supplier for the Btu content of the fuel. Required fuel pressur ...

  • Generac 5818 - page 9

    7 Install the unit where ser vices will not be affected or obstr ucted, • including concealed, underground or covered ser vices such as electrical, fuel, phone, air conditioning or irrigation. Where strong prevailing winds blow from one direction, face the • generator air inlet openings to the prevailing winds. Install the generator as close as ...

  • Generac 5818 - page 10

    8 General Information Figure 1.4 – Installation Guidelines 18 inches Minimum Distance 36 inches 36 inches 36 inches 60 inches 60 inches Existing W all No windows or openings in the wall permitted within 5 feet from any point of the generator . T op of Generator 60” Minimum 60” Recommended Minimum From Ends 18 inches Minimum Generator Clearanc ...

  • Generac 5818 - page 11

    9 1.10 BA T TERY REQUIREMENTS See the Specifications section for correct batter y size and rating. 1.11 BA T TERY INST ALLA TION Fill the batter y with the proper electrolyte fluid if necessar y and have the batter y fully charged before installing it. Before installing and connecting the batter y , complete the follow- ing steps: 1. Set the genera ...

  • Generac 5818 - page 12

    10   Be sure the utility power supply is turned off and the 7.5A fuse is removed from the gen- erator control panel, or sparking may occur at the battery posts as the cables are attached and cause an explosion. Ser vicing of the batter y is to be per for med or super vised by per - sonnel knowledgeable of batteries and the required precaution ...

  • Generac 5818 - page 13

    11 ACTIVA TION CHART CHOOSE LANGUAGE TROUBLESHOOTING Display Reads: Use ARROW keys to scroll to desired lan- guage. Press ENTER to select. If the wrong language is chosen, it can be changed later using the “edit” menu. Display Reads: Press ENTER to begin the activation pro- cess. If ESCAPE is pressed instead of ENTER, your generator will only r ...

  • Generac 5818 - page 14

    12 5. When cer tain that input voltage is compatible with batter y charger ratings, turn OFF the power supply to the generator . 6. On the generator panel, set the Auto/Off/ Manual switch to MANUAL. The engine should crank and star t. 7. Let the engine war m up for about five minutes to allow inter - nal temperatures to stabilize. Then, set the gen ...

  • Generac 5818 - page 15

    13 Operation Figure 3.1 – Generator Control P anel Escape MAIN FUSE AUT O OFF MANUAL 7.5 AMP Enter Upon first power up of the generator , the display inter face will begin an installation assistant. The assistant will prompt the user to set the minimum settings to operate. These settings are Current Date/Time. The maintenance inter vals will be i ...

  • Generac 5818 - page 16

    14 Cranking Conditions The following notes apply during cranking cycle. 1. Star ter motor will not engage within five (5) seconds of the engine shutting down. 2. The fuel output will not be energized with the star ter . 3. The star ter and magneto outputs will be energized together . 4. Once the star ter is energized the control board will begin lo ...

  • Generac 5818 - page 17

    15 High Engine T emperature (Shutdown Alarm – Auto Reset) A 10 second delay on star t-up and one (1) second delay before shutdown. Auto reset when the condition clears and restar t the engine if a valid star t signal is still present. This switch’s contacts (Figure 3.4) close if the temperature should exceed approximately 140° C (284° F), ini ...

  • Generac 5818 - page 18

    16 4.1 FUSE The 7.5 amp fuse on the control panel protects the DC control circuit against overload (Figures 3.1 and 3.2). This fuse is wired in series with the batter y output lead to the panel. If this fuse ele- ment has melted open, the engine will not be able to crank or star t. Replace this fuse using only an identical 7.5 amp replacement fuse. ...

  • Generac 5818 - page 19

    17 4.3.3 OIL & OIL FIL TER CHANGE PROCEDURE T o change the oil, proceed as follows: 1. Star t the engine by moving the AUTO/OFF/MANU AL switch to MANUAL and run until it is thoroughly war med up. Then shut OFF the engine by moving the switch to the OFF position. 2. Immediately af ter the engine shuts OFF , pull the oil drain hose (Figure 4.1) f ...

  • Generac 5818 - page 20

    18 4.6 BA T TERY MAINTENANCE The batter y should be inspected per the "Ser vice Schedule" sec- tion. The following procedure should be followed for inspection: 1. Inspect the batter y posts and cables for tightness and cor ro- sion. Tighten and clean as necessar y . 2. Check the batter y fluid level of unsealed batteries and, if nec- essa ...

  • Generac 5818 - page 21

    19 When valve clearance is correct, hold the pivot ball stud in place with the allen wrench and tighten the rocker arm jam nut. Tighten the jam nut to 174 in/lbs. torque. Af ter tightening the jam nut, recheck valve clearance to make sure it did not change. Install new valve cover gasket. • Re-attach the valve cover . • NOTE: Start all four scr ...

  • Generac 5818 - page 22

    20 4.11.2 RETURN TO SERVICE T o retur n the unit to ser vice af ter storage, proceed as follows: 1. V erif y that utility power is turned off and that the AUTO/OFF/ MANUAL switch is set to OFF . 2. Check the tag on the engine for oil viscosity and classification. V erify that the cor rect recommended oil is used in the engine (see the Engine Oil Re ...

  • Generac 5818 - page 23

    21 Maintenance 4.12 SERVICE SCHEDULE A T TENTION: It is recommended that all service work be performed by the nearest Dealer . SYSTEM/COMPONENT PROCEDURE FREQUENCY X = Action R = Replace as Necessary * = Notif y Dealer if Repair is Needed. Inspect Change Clean W = Weekly M = Monthly Y = Y early FUEL Fuel lines and connections* XM L UBRICA TION Oil ...

  • Generac 5818 - page 24

    22 T roubleshooting 5.1 TROUBLESHOOTING GUIDE Problem Cause Correction The engine will not crank. 1. F use blown. 1. Cor rect shor t circuit condition, replace 7.5A fuse in generator control panel. 2. Loose, corroded or defective 2. Tighten, clean or replace batter y cables. as necessar y . 3. Defective star ter motor . 3. * 4. Dead Batter y . 4. C ...

  • Generac 5818 - page 25

    23 Appendix 6.1 MENU SYSTEM NA VIGA TION T o get to the MENU, use the "Esc" key from any page. It may need to be pressed many times before getting to the menu page. The currently selected menu is displayed as a flashing word. Navigate to the menu required by using the +/- keys. When the menu required is flashing, press the ENTER key . Dep ...

  • Generac 5818 - page 26

    24 Appendix MAIN MENU RUN LOG ALARM LOG HISTOR Y ST A TUS COMMAND ST A TE VERSIONS DISPLA Y GENERA TOR FREQUENCY ENGINE HOURS ENGINE RPM BA TTERY VO LTAG E DEBUG INPUTS OUTPUTS DISPLA YS EDIT CONTRAST LANGU AGE TIME/DA TE EXERCISE TIME/SPEED ESC Press the “ESCAPE” key to jump back up through the menu levels. + / - Use the “+/-” key to navig ...

  • Generac 5818 - page 27

    Generac ® Pow er Systems, Inc. 25 25 Drawing No. 0J1320-B Installation Diagram ...

  • Generac 5818 - page 28

    26 Generac ® Pow er Systems, Inc. 26 Installation Diagram Drawing No. 0J1320-B ...

  • Generac 5818 - page 29

    Generac ® Pow er Systems, Inc. 27 27 Drawing No. 0J1320-B Installation Diagram ...

  • Generac 5818 - page 30

    28 Generac ® Pow er Systems, Inc. 28 28 ENGINE CONTROLLER VOLTAGE REGULATOR (AVR) ENGINE START BATTERY CHARGER 12 VOLT ENGINE START BATTERY ALTERNATOR BATTERY CHARGER INVERTER TWO-WIRE START BATTERY VOLTAGE SENSING AC DISTRIBUTION PANEL 120/240V DC DISTRIBUTION PANEL 12V/24V/48V BATTERY 12V/24V/48V INVERTER/CHARGER GENERATOR HOUSE HOUSE LOADS HOUS ...

  • Generac 5818 - page 31

    29 Drawing No. 0J1323-C Oil Make-up System ...

  • Generac 5818 - page 32

    30 Notes ...

  • Generac 5818 - page 33

    31 Notes ...

  • Generac 5818 - page 34

    32 FOR GENERA TORS 10KW AND BELOW FEDERAL EMISSION CONTROL WARRANTY ST ATEMENT YOUR W ARRANTY RIGHTS AND OBLIGATIONS The United States Environmental Protection Agency (EP A) and Generac P ower Systems, Inc. (Generac) are pleased to explain the Emission Control System warranty on your new 2008 and later equipment. New equipment that use small spark- ...

  • Generac 5818 - page 35

    33 EMISSION CONTROL SYSTEM WARRANTY Emission Control System Warranty (ECS war ranty) for equipment using small spark-ignited engines: (a) Applicability: This warranty shall apply to equipment that uses small off -road engines. The ECS Warranty period shall begin on the date the new equipment is purchased by/delivered to its original, end-use purcha ...

  • Generac 5818 - page 36

    Part No. 0J0984 Revision B (05/27/11) Printed in U .S.A. W arranty GENERAC POWER SYSTEMS LIMITED WARRANTY FOR "ECO GEN AIR-COOLED AUTOMA TIC ST ANDB Y GENERA TORS" For a period of three (3) years or 2000 hours, whichever comes first, from the date of original sale Generac P ower Systems, Inc . (Generac) war rants that its standby generato ...

Fabbricante Generac Categoria Portable Generator

I documenti che otteniamo dal fabbricante del dispositivoGenerac 5818 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Generac
- manuali per l’uso 5818
- schede prodotto Generac
- opuscoli
- o etichette energetiche Generac 5818
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Generac 5818.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Generac 5818, manuali di manutenzione, brevi manuali o manuali utente Generac 5818. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Generac 5818.

Manuali per l’uso simili

Manuale completo del dispositivo Generac 5818, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Generac 5818 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Generac 5818.

Il manuale per l’uso completo Generac, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Generac 5818 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Generac 5818, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Generac 5818 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Generac 5818 - che ci dovrebbe aiutare nei primi passi durante l'uso Generac 5818
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Generac 5818
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Generac 5818 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Generac 5818?

Utilizza il modulo sottostante

Se non hai risolto il problema con Generac 5818 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Generac 5818 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)