  • Fluke 175 - page 1

    ® Models 175, 177, 179 True RMS Multimeters Users Manual May 2003 (English) © 2003 Fluke Corporation. All right s reserved. Printed in USA. ...

  • Fluke 175 - page 2

    Lifeti m e Limi ted Warr a n ty Ea c h Fl u k e 20, 70, 80, 17 0 and 18 0 S eri es DM M wil l b e f ree f rom de f e c ts in m a t eri al an d wor k ma n s hi p f or i t s li f e t ime. As u s ed h erein, “li f e- t ime ” is de f ined a s s e v e n y ears a ft e r Fl u k e dis c on t inues man u f ac t uri ng t h e produ c t, b u t t he warran ...

  • Fluke 175 - page 3

    i Table of Contents Titl e Page Con tacting Fluk e ............................................................................................................... .... 1 "Warn ing" and "C aution " State ments ..................................................................................... 1 Unsafe Vol tage ................. ...

  • Fluke 175 - page 4

    ii Warning . Rea d be fore u sing the Mete r: To avoid possible electrical shock or personal injury, follow these guidelines: ⇒ Use the Meter only as spec ified in this ma nual or the pr otection p rovided by t he Meter might be im paired. ⇒ Do not use the Meter or test leads if they appear damaged , or if the Meter is not operating pr operly. ...

  • Fluke 175 - page 5

    1 Models 175, 177 & 179 True RMS Multimeters The Fluke Model 175 , Model 177 , and Model 179 are batter y - powered, t rue-RMS m u l t i me t ers (herea ft er " t he Me t er" ) wi t h a 6000- c ount, 3 3/4-di gi t di s play and a bar graph. Thi s manual applies t o al l t hree m odel s . All f igures s how the M odel 179. These meters ...

  • Fluke 175 - page 6

    Models 175, 177 & 179 Users M anual 2 Battery Saver ("Sleep Mode") The Meter enters the "Sleep m ode" and blanks t he di s play if t here is no func tion change or but t on press for 20 m inutes. To di s able the Sleep m ode, hol d down t he YELLOW button while t urni ng t he Meter on. The S l eep m ode i s always di s abled ...

  • Fluke 175 - page 7

    Displ ay 3 Display . 8 7 7 5 6 4 3 2 1 13 14 15 9 11 12 10 AIK02F.EPS No. Symbol Meaning 1 s Continuit y t est. 2 Diode test . 3 K Negative readi ngs . 4 Y Unsafe v ol t age. Voltage ≥ 30 V , or voltage ov erload ( OL ) 5 Displ ay HOLD is enabl ed. Display freezes pres ent reading. In MIN M AX AV G mode, MI N MAX AVG recordi ng i s interrupted. A ...

  • Fluke 175 - page 8

    Models 175, 177 & 179 Users M anual 4 MIN MAX AVG Recording M ode The MIN MA X A VG recording m ode c aptures the m i ni m um and maximum input values , and calc ulates a runni ng av erage of all readings. When a new hi gh or l ow i s detected, the Meter beeps . Note For DC funct i ons , accurac y is the s pecifi ed ac curacy of t he measuremen ...

  • Fluke 175 - page 9

    Manual Ranging and Autoranging 5 Manual Ranging and Autoranging The Meter has bot h Manual range and Autorange m odes . ⇒ In the Aut orange mode, the M et er s elects the range with t he best res ol ut i on. ⇒ In the Manual Range m ode, you override A ut orange and select the range yoursel f . When you turn the M eter on, it def aults t o A uto ...

  • Fluke 175 - page 10

    Models 175, 177 & 179 Users M anual 6 Making Basic Measurements The figures on t he f ollowing pages s how how to make bas ic measurement s. When connect i ng t he t est leads to the ci rc uit or devi c e, connect the comm on ( COM ) test l ead bef ore c onnecting t he live lead; when removing t he t est leads , remove the l i v e lead before r ...

  • Fluke 175 - page 11

    Making Basic Measurem ents 7 Testing for Continuit y RANGE HOLD MIN MA X RANGE HOLD MIN MA X AIK06F.EPS Measuring Temperature (Model 179 Only) RANGE HOLD MIN MAX 80BK1 Type K Thermocouple Probe Vent or Pipe RANGE AIK10F.EPS Warning: Do not connect 80BK1 to liv e c irc uit s . Testing Diodes + __ Forward Bias Single Beep + Reverse Bias Good Diode Go ...

  • Fluke 175 - page 12

    Models 175, 177 & 179 Users M anual 8 Measuring AC or DC Current Warning To avoid personal injury or damage to the Meter: • Never attempt to make an i n-ci rcuit current measure- ment when the open-circuit potential to earth is > 1000 V. • Check the Meter's fuses before testing. (See “ Testing the Fuses”.) • Use the proper ter ...

  • Fluke 175 - page 13

    Using the Bar Graph 9 Measuring Frequency Warning To avoid electrical shock, di sregard the bar graph for frequencies > 1 kHz. I f the frequency of the m easured signal is > 1 kHz, the bar graph is unspecified. The Meter meas ures the frequency of a signal . The trigger level i s 0 V, 0 A A C f or all ranges. + RANGE HOLD MIN MAX Hz RANGE HOL ...

  • Fluke 175 - page 14

    Models 175, 177 & 179 Users M anual 10 Cleaning Wipe the cas e with a damp c l ot h and m i l d det ergent. Do not us e abrasives or solvent s . Dirt or m oi s ture in the t erm i nal s can aff ec t readings. Testing the Fuses Warning To avoid electrical shock or injury, rem ove the test leads and any input signals before replacing the fuse. Te ...

  • Fluke 175 - page 15

    Specifications 11 Specifications Accuracy is s pec if ied f or 1 y r af t er c alibrat ion, at operat ing t emperatures of 18 ° C to 28 ° C, with relative humidity at 0 % t o 95 %. Ac c urac y specificat ions t ak e t he f orm of: ± ( [ % of Reading ] + [ Counts ] ) Maximum voltage between any termi nal and earth gr ound: 1000 V DC or AC RM S Su ...

  • Fluke 175 - page 16

    Models 175, 177 & 179 Users M anual 12 Accuracy ± ( [ % of Reading ] + [ Counts ] ) Function Range 1 Res ol ution Model 17 5 Model 177 Model 17 9 AC Volts 2,3 600.0 mV 6.000 V 60.00 V 600.0 V 1000 V 0.1 mV 0.001 V 0.01 V 0.1 V 1 V 1.0 % + 3 (45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) 1.0 % + 3 (45 Hz to 500 Hz) 2.0 % + 3 (500 Hz to 1 kHz) 1. ...

  • Fluke 175 - page 17

    Specifications 13 Accuracy ± ( [ % of Reading ] + [ Counts ] ) Function Range 1 Res ol ution Model 17 5 Model 177 Model 17 9 DC Amps 4 60.00 mA 400.0 mA 6.000 A 10.00 A 0.01 mA 0.1 mA 0.001 A 0.01 A 1.0 % + 3 1.0 % + 3 1.0 % + 3 Hz (AC- or DC- coupled, V or A 2, 3 input ) 99.99 Hz 999.9 Hz 9.999 kHz 99.99 kHz 0.01 Hz 0.1 Hz 0.001 kHz 0.01 kHz 0.1 ...

  • Fluke 175 - page 18

    Models 175, 177 & 179 Users M anual 14 Function Overload Protection 1 Input Im pe da nc e (Nominal) Common Mode Rejection Ratio (1 k Ω Unbalanced) Normal Mode Rejecti on Volts AC 1000 V RMS > 10 M Ω < 100 pF > 60 dB @ DC, 50 Hz or 60 Hz Volts DC 1000 V RMS > 10 M Ω <100 pF >120 dB @ DC, 50 Hz or 60 Hz > 60 dB @ 50 Hz ...

Fabbricante Fluke Categoria Video Game Keyboard

I documenti che otteniamo dal fabbricante del dispositivoFluke 175 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Fluke
- manuali per l’uso 175
- schede prodotto Fluke
- opuscoli
- o etichette energetiche Fluke 175
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Fluke 175.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Fluke 175, manuali di manutenzione, brevi manuali o manuali utente Fluke 175. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Fluke 175.

Manuali per l’uso simili

Manuale completo del dispositivo Fluke 175, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Fluke 175 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Fluke 175.

Il manuale per l’uso completo Fluke, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Fluke 175 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Fluke 175, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Fluke 175 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Fluke 175 - che ci dovrebbe aiutare nei primi passi durante l'uso Fluke 175
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Fluke 175
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Fluke 175 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Fluke 175?

Utilizza il modulo sottostante

Se non hai risolto il problema con Fluke 175 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Fluke 175 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)