Manuale per l’uso Patton electronic 2500 Series

20 pagine 0.35 mb
Scarica

Vai alla pagina of 20

Summary
  • Patton electronic 2500 Series - page 1

    USER MANUAL MODEL 2500 Series Models 2500, 2510, 2520 All-Rate CSU/DSU SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 P ar t# 07M2500-C Doc# 099021UC Revised 3/13/96 ...

  • Patton electronic 2500 Series - page 2

    T ABLE OF CONTENTS Section P age 1.0 General Inf ormation ...............................................................2 1.1 W arr anty Statement 1.2 Radio and TV Interf erence 1.3 FCC Inf or mation 1.4 Ser vice Inf or mation 2.0 Product Ov er vie w ..................................................................4 2.1 Product F eatures 2.2 Gene ...

  • Patton electronic 2500 Series - page 3

    2.0 PRODUCT OVERVIEW This section provides an o v er view of the Model 2500 Series, including f eatures , general description, and a breakdown of model numbers b y application. 2.1 PR ODUCT FEA TURES • Operates ov er 4-wire dedicated digital lines • Suppor ts rates of 56 kbps and 64 kbps and all sub rates • Suppor ts Switched 56 dialing • P ...

  • Patton electronic 2500 Series - page 4

    3.0 INST ALLA TION This section descr ibes connection of the Model 2500 Ser ies to the DTE and telco (line) interf aces , as well as AC pow er connection 3.1 DTE INTERF A CE CONNECTION The Model 2500 Ser ies has connectors f or both V .35 and RS-232 interf aces . Signals output b y the Model 2500 Series will appear on both interf aces . An inter na ...

  • Patton electronic 2500 Series - page 5

    4.0 CONFIGURA TION Bef ore y ou can operate your Model 2500 Series CSU/DSU , you must configure the unit. Configur ation ma y be done using the e xter nally accessib le hardware s witches or b y using the software s witches . Software switches can be accessed from the front panel control por t using a VT -100 type RS-232 ter minal that responds to ...

  • Patton electronic 2500 Series - page 6

    4.1.1 SWITCH SET SW1 The configuration s witches on s witch set SW1 allo w you to specify Line Rate , Circuit Assurance , R TS, Char acter Length, Data Format and DSR Loop Status. Figure 3 (belo w) summar iz es SW1 s witch settings , including the f actor y def aults. F ollowing Figure 4 is a description of each s witch setting. Line Rate These s w ...

  • Patton electronic 2500 Series - page 7

    Character Length In asynchronous data f or mat, 10 and 11 bit characters are suppor ted. This setting is ignored in synchronous data format. Character Char acter Descr iption SW1-6 Length Start Data bits P ar ity Stop bits Off 10-bit 1 8 None 1 or more 1 7 1 1 or more 1 7 None 2 On 11-bit 1 8 1 1 or more 1 9 None 1 or more Data Format The data f or ...

  • Patton electronic 2500 Series - page 8

    DTE Loop Contr ol The local loop and remote loop can be activ ated from the DTE interf ace using signals “LL ” and “RL ”. SW2-4 On Enab le LL and RL inputs Off Disab le Cloc k Mode The appropriate transmitter cloc king modes can be selected f or Dedicated DDS , Switched-56 or campus-area (pr iv ate) operation. SW2-5 SW2-6 Mode Descr iption ...

  • Patton electronic 2500 Series - page 9

    4.2.1 USING THE SOFTW ARE MENU SYSTEM The Model 2500 Ser ies Men u System operates as f ollo ws: 1) All selections must be follo wed by [RETURN]. 2) T o mak e a selection from an y menu, enter the option number at the prompt and press [RETURN]. 3) T o e xit an y menu without making a selection, press [ESC] f ollo wed by [RETURN]. (Note: Y ou can al ...

  • Patton electronic 2500 Series - page 10

    Character Length Choosing option 4 in the Softw are Switch Men u takes you to the Character Length Men u (below). In asynchronous data f or mat, the Model 2500 Ser ies suppor ts 10-bit and 11-bit character lengths . Set this option according to the characteristics of the data being transmitted. DTE Data Format Choosing option 5 in the Softw are Swi ...

  • Patton electronic 2500 Series - page 11

    Note 2 : Y ou can use the Model 2500 Ser ies to transmit low er-speed asynchronous data (up to 9.6 kbps) ov er synchronous circuits b y simple o ver-sampling. T o do this, select the synchronous data f or mat and set the line Line Rate (Softw are Switch Men u option 1) to at least f our times that asynchronous data rate y ou wish to send. F or e xa ...

  • Patton electronic 2500 Series - page 12

    21 22 Cloc k Mode Choosing option 9 in the Software Switch Men u takes y ou to the Cloc k Mode Menu (belo w). Set this option as f ollo ws: • Internal (Master): T o use the Model 2500 Ser ies inter nal reference cloc k as the timing source, select item 1. Use inter nal timing in point-to- point applications where the Model 2500 Ser ies is being u ...

  • Patton electronic 2500 Series - page 13

    5.0 OPERA TION Once the Model 2500 Ser ies unit is installed and configured proper ly it is ready to oper ate. This section describes the function of the LED indicators, the status displa ys, the use of loopbac k test modes, and Switched 56 dialing procedures (Models 2510 and 2520 only). 5.1 LED DESCRIPTIONS The Model 2500 Ser ies is equipped with ...

  • Patton electronic 2500 Series - page 14

    25 26 In the Read Configuration Men u, you ma y select item 1 to read the hardw are s witch configuration or item 2 to read the software s witch configuration. A sample screens is sho wn below: 5.2.2 DISPLA YING LINE/LOOP ST A TUS T o chec k the current status of the Model 2500 Ser ies and the associated circuit, go to the Main Menu (see Section 4. ...

  • Patton electronic 2500 Series - page 15

    27 28 LAL T est Pr ocedure Once LAL is activ ated, the Model 2500 Ser ies tr ansmit output is connected to its own receiv er . The “T est” LED should be lit. F ollo w these steps to complete the test: 1) V erify that the data ter minal equipment is operating properly and can be used f or a test. If a f ault is indicated, call a technician or re ...

  • Patton electronic 2500 Series - page 16

    29 30 CSU Loop The CSU Loop is activ ated when the central office re v erses the DC sealing current that flows betw een the TX pair and the RX pair . In this case , the Model 2500 Ser ies recognizes this and loops signals on the RX pair bac k to the central office on the TX pair (see Figure 8, below). While the CSU Loop is activ ated by the centr a ...

  • Patton electronic 2500 Series - page 17

    31 32 5.5 SWITCHED 56 DIALING COMMANDS (MODELS 2510 & 2520) T o access the Switched 56 dialing capabilities of the Mode 2500 Ser ies , go to the Main Menu (see Section 4.2 ) and select item 5, “Set Switched 56 Dialing P ar ameters”. This will take y ou to the Switched 56 Menu (see belo w). The f ollowing par agraphs describe the commands in ...

  • Patton electronic 2500 Series - page 18

    33 34 APPENDIX A SPECIFICA TIONS DDS T ype: Dedicated T ransmission Format: Asynchronous, synchronous Interface: RS-232 and V .35 Standar ds: A T&T 62310 compliant DDS Line Rates: 2.4, 4.8, 9.6, 19.2, 56 and 64 kbps DTE Rates: 2.4, 4.8, 9.6, 19.2, 38.4, 56, and 64 kbps; 57.6 kbps, async , 2 stop bits Contr ol P or t: Configuration and diagnosti ...

  • Patton electronic 2500 Series - page 19

    35 36 APPENDIX C F A CT OR Y REPLACEMENT P ARTS AND A CCESSORIES P atton Model # Description 10-2500 ...........................DDS Cab le, RJ48 - RJ48, 6 f oot 10-561S ...........................Control P or t Cable, EIA-561, 6ft, shielded 12M-561 ..........................Adapter , EIA-561 to DB-25 Male 12F-561 ...........................Adapter ...

  • Patton electronic 2500 Series - page 20

    (APPENDIX D - Continued) DB-25 CONNECT OR, TERMINAL INTERF A CE Pin # Signal 1 F rame Ground 2 TD 3 RD 4 R TS 5 CTS 6 DSR 7 SGND (Signal Ground) 8 CD 15 TC 17 RC 18 LL (Local Loop) 20 DTR 21 RL (Remote Loop) 24 XTC 25 TM (T est Mode) CONTR OL PORT INTERF A CE 8 P osition modular connector compliant with EIA-561. Pin # Signal 4 Signal Ground 5 RD (O ...

Fabbricante Patton electronic Categoria Portable Generator

I documenti che otteniamo dal fabbricante del dispositivoPatton electronic 2500 Series possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Patton electronic
- manuali per l’uso 2500 Series
- schede prodotto Patton electronic
- opuscoli
- o etichette energetiche Patton electronic 2500 Series
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Patton electronic 2500 Series.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Patton electronic 2500 Series, manuali di manutenzione, brevi manuali o manuali utente Patton electronic 2500 Series. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Patton electronic 2500 Series.

Manuale completo del dispositivo Patton electronic 2500 Series, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Patton electronic 2500 Series dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Patton electronic 2500 Series.

Il manuale per l’uso completo Patton electronic, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Patton electronic 2500 Series - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Patton electronic 2500 Series, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Patton electronic 2500 Series che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Patton electronic 2500 Series - che ci dovrebbe aiutare nei primi passi durante l'uso Patton electronic 2500 Series
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Patton electronic 2500 Series
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Patton electronic 2500 Series in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Patton electronic 2500 Series?

Utilizza il modulo sottostante

Se non hai risolto il problema con Patton electronic 2500 Series con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Patton electronic 2500 Series è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine