Manuale per l’uso Renesas FP-144

20 pagine 0.39 mb
Scarica

Vai alla pagina of 20

Summary
  • Renesas FP-144 - page 1

    H8S/2643 Series FP-144 User System Interface Cable (HS2643ECH61H) for E6000 Emulator User’s Manual HS2643ECH61HE(C) ...

  • Renesas FP-144 - page 2

    Cautions 1. Renesas neither warrants nor grants li censes of any rights of Renesas’s or any t hird party’s patent, copyright, t rademark, or other intel lect ual property rights for informat ion contained in this document. Renesas bears no responsibility fo r problem s that may arise with third party’s rights, including int ellectual property ...

  • Renesas FP-144 - page 3

    i Preface Thank you for purchasing this user system interface cable (HS2643ECH61H) for the Renesas’s original mi crocomputer H8S/2643 series. The HS2643ECH61H is a user system interface cable that connects an H8S/2633 series E6000 emulator (HS2633EPI61H; hereinafter referred to as the emul ator) to the IC socket for a FP-144 package for the H8S/2 ...

  • Renesas FP-144 - page 4

    ii Contents Section 1 Configuration .................................................................................... 1 Section 2 Connection Procedures ...................................................................... 3 2.1 Connecting User System Interf ace Cable to Em ulat or Station ......................................... 3 2.2 Connecti ...

  • Renesas FP-144 - page 5

    Section 1 Configuration CAUTION Use an NQPACK144SD socket (manufactured by Toky o Eletech Corporation) for the FP-144 package IC socket on the user system. Figure 1 shows the configuration of the HS2643E CH61H user system interface cable for the FP-144 package. Figure 1 HS2643ECH61H User System Interface Cable 1 ...

  • Renesas FP-144 - page 6

    2 Table 1 lists t he HS2643ECH61H components. Please m ake sure you have all of these com ponents when unpacking. Table 1 HS2643ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP-144 package 4 Socket cover 1 For installing a FP-144 packaged MCU 5 Screws (M2 x 10 mm) 4 For fastening cab ...

  • Renesas FP-144 - page 7

    Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station W ARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and w ill damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system a ...

  • Renesas FP-144 - page 8

    Emulator station E6000 Cable body connector User system interface cable Figure 2 Connecting User System Int erface Cable to Emulator Station 4 ...

  • Renesas FP-144 - page 9

    2.2 Connecting User System Interface Cable to User System W ARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the ...

  • Renesas FP-144 - page 10

    IC socket (NQPACK144SD manufactured by Tokyo Eletech Corporation) User system Guide pins 4 projections to apply epoxy resin adhesive to Bottom view of IC soket Pin 1 Figure 3 Location Setting of IC Socket 2.2.2 Soldering IC Socket After fastening, solder the IC socket for a FP-144 package to the user system. CAUTION Be sure to completely solder the ...

  • Renesas FP-144 - page 11

    7 2.2.4 Fastening Cable Head CAUTION 1. Use the screwdriver provided for tightening screw s. 2. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightene ...

  • Renesas FP-144 - page 12

    Fasten the user system interface cab le head to the IC socket for a FP-144 package on the user system with the four screws (M2 x 10 mm) provided. Each screw shoul d be tightened a little at a tim e, alternating between screws on opposing corners. Take speci al care, such as manually securing the IC socket soldered area, to pr event the soldered IC ...

  • Renesas FP-144 - page 13

    2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Cable head Remove jig Push the remove jig Removing User system Figure 5 Fastening Cable Body 9 ...

  • Renesas FP-144 - page 14

    2.3 Recommended Dimensions for User System Mount Pad Figure 6 shows t he recomm ended dim ensions for the mount pad (footprint) for the user system with an IC socket for a FP-144 package (NQPACK144SD: m anufactured by Tokyo Eletech Corporation). Not e that the dimensions in figure 6 are somewhat different from those of t he actual chip's m oun ...

  • Renesas FP-144 - page 15

    2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interf ace cable head are shown in figure 7. Figure 7 Dimensions for User System Interface Cable Head 11 ...

  • Renesas FP-144 - page 16

    2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after conn ecting the user system interface cab le head to the user system, are shown in figure 8. Figure 8 Resulting Dimensions after Connecting User System Interface Cable 12 ...

  • Renesas FP-144 - page 17

    13 Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use the screwdriver provided for tightening screw s. 3. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly ...

  • Renesas FP-144 - page 18

    MCU Pin 1 IC socket (NQPACK144SD manufactured by Tokyo Eletech Corporation) User system Screws (M2 x 6 mm) Socket cover Figure 9 Installing MCU to User System 14 ...

  • Renesas FP-144 - page 19

    Section 4 Verifying Operation 1. When using the E6000 emulator for the H8S/2633 series, turn on the emulator according to the procedures described in the H8S Series E6000 Em ulator User's Manual (HS2000EPI61HE). 2. Verify the user system interface cable connec tions by accessing the exte rnal m emory and ports to check the bus states of the pi ...

  • Renesas FP-144 - page 20

    Section 5 Notice 1. Make sure that pin 1 on the user syst em IC socket is correct ly aligned with pin 1 on t he cable head before inserting the cable head into the user system IC socket. 2. The dimensions of t he recommended m ount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specifi ...

Fabbricante Renesas Categoria Computer Hardware

I documenti che otteniamo dal fabbricante del dispositivoRenesas FP-144 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Renesas
- manuali per l’uso FP-144
- schede prodotto Renesas
- opuscoli
- o etichette energetiche Renesas FP-144
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Renesas FP-144.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Renesas FP-144, manuali di manutenzione, brevi manuali o manuali utente Renesas FP-144. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Renesas FP-144.

Manuali per l’uso simili

Manuale completo del dispositivo Renesas FP-144, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Renesas FP-144 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Renesas FP-144.

Il manuale per l’uso completo Renesas, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Renesas FP-144 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Renesas FP-144, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Renesas FP-144 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Renesas FP-144 - che ci dovrebbe aiutare nei primi passi durante l'uso Renesas FP-144
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Renesas FP-144
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Renesas FP-144 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Renesas FP-144?

Utilizza il modulo sottostante

Se non hai risolto il problema con Renesas FP-144 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Renesas FP-144 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)