    1 P ART NO. 184707-001 GPDH/GPDT/GPDX GAS MODELS with Hot Surface Ignition CAUTION TEXT PRINTED OR OUTLINED IN RED CONT AINS INFORMA TION RELA TIVE T O YOUR SAFETY . PLEASE READ THOROUGHL Y BEFORE INST ALLING AND USING THIS APPLIANCE. KEEP THIS MANUAL IN THE POCKET ON HEA TER FOR FUTURE REFERENCE WHENEVER MAINTENANCE ADJUSTMENT OR SERVICE IS REQUIR ...

  • A.O. Smith GPDX - page 2

    2 GET TO KNOW YOUR W A TER HEA TER REPLACEMENT P ARTS AND DELIMING PRODUCTS A VENT PIPE-EXHAUST B ANODE C HOT W A TER OUTLET D OUTLET (1 15 V . AC) E FLUE BAFFLE F GAS SUPPL Y G MAIN MANUAL GAS SHUT OFF V A L VE H GROUND JOINT UNION J DIRT LEG K OUTER DOOR L UNION M INLET WA TER SHUT OFF V AL VE N COLD WA TER INLET O INLET DIP TUBE P TEMPERA TURE A ...

  • A.O. Smith GPDX - page 3

    3 GENERAL SAFETY INFORMA TION EXTERNAL DAMAGE Do not operate the water heater until it has been fully checked out by a qualified technician, if the water heater: • Has been exposed to fire or damage. • Displays evidence of sooting. • Produces steam or unusually hot water . If the water heater has been flooded it must be replaced. CHEMICAL V A ...

  • A.O. Smith GPDX - page 4

    4 Canadian S tandards Association, 8501 East Pleasant V alley Road, Cleveland, OH 44131, and both documents are available from the National Fire Protection Association, 1 Batterymarch Park, Quincy , MA 02269. The appliance, when installed, must be electrically grounded in accordance with local codes or in the absence of local codes with the current ...

  • A.O. Smith GPDX - page 5

    5 CLOSED W A TER SYSTEM A closed system will exist if a back-flow preventer (check valve), pressure reducing valve, or other similar device is installed in the cold water line between the water heater and the street main (or well). Excessive pressure may develop due to the thermal expansion of heated water causing premature tank failure or intermit ...

  • A.O. Smith GPDX - page 6

    6 COMBUSTION AIR AND EXHAUST W ARNING WHEN DETERMINING THE INST ALLA TION LOCA TION FOR A POWER DIRECT VENT WA TER HEA TER, SNOW ACCUMULA TION AND DRIFTING SHOULD BE CONSIDERED IN AREAS WHERE APPLICABLE. V enting Through an Outside W all - Clearances • 0" clearance for 3" PVC, ABS, or CPVC Schedule 40 piping from combustible surfaces. ? ...

  • A.O. Smith GPDX - page 7

    7 W ARNING VENT TERMINA TION MUST NOT BE WITHIN 4 FEET (122 cm) OF ANY ITEMS SUCH AS GAS METERS, GAS V AL VES OR OTHER GAS REGULA TING EQUIPMENT . WIRE FENCE When the water heater outlet terminal is low enough to be touched accidentally , or is accessible to small children, a wire mesh chain link fence (as show in Figure 7) may be used. Care should ...

  • A.O. Smith GPDX - page 8

    8 FIGURE 1 1. STANDARD MODELS. * If making an immediate horizontal run of vent off the blower , two 3" PVC or ABS Schedule 40 street elbows are required. 1. The water heater requires its own (separate) venting system. 2. 3" PVC, ABS or CPVC Schedule 40 piping and fittings are acceptable materials for the vent system. 3. It cannot be conne ...

  • A.O. Smith GPDX - page 9

    9 FIGURE 17. Cementing PVC, ABS or CPVC Pipe and Fittings Read and observe all safety information printed on printer , cleaner , and cement container . DANGER Primer , cleaner , and cements are extremely flammable. They are harmful or fatal if swallowed. The vapors are harmful. They may irritate eyes and skin and can be absorbed through the skin. P ...

  • A.O. Smith GPDX - page 10

    10 wall will help minimize discoloration of the wall. Note that the inside flue mounting adaptors must be slipped over the vent piping before locating the pipe through the wall. Before securing the inside and outside collars to the wall, use a silicone sealer between pipe and opening to insure a water and air tight seal. INST ALLA TION SHOWING USE ...

  • A.O. Smith GPDX - page 11

    11 GROUNDED IN ACCORDANCE WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES, WITH THE NA TIONAL ELECTRICAL CODE, ANSI/NFPA 70. If local codes do not permit use of a flexible power supply cord. OPTIONAL Field Installed Wiring 1. Remove screws to remove wiring junction cover . 2. A standard 1/2" conduit opening has been made in the water heater ...

  • A.O. Smith GPDX - page 12

    12 FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING: If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life. A . This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the burner . Do NOT try to light the pilot by hand. ...

  • A.O. Smith GPDX - page 13

    13 OPERA TION NEVER OPERA TE THE HEA TER WITHOUT FIRST BEING CERT AIN IT IS FILLED WITH W A TER AND A TEMPERA TURE AND PRESSURE RELIEF V AL VE IS INST ALLED IN THE RELIEF V AL VE OPENING OF THE HEA TER. DO NOT A TTEMPT T O OPERA TE HEA TER WITH COLD W A TER INLET V AL VE CLOSED. FILLING 1. Close the heater drain valve by turning handle clockwise, F ...

  • A.O. Smith GPDX - page 14

    14 W A TER HEA TING IGNITION SEQUENCE (Make sure gas and electric power are connected properly) 1. The ignition control module is powered and monitors the system, waiting for a call for heat from the thermostat. 2. The thermostat calls for heat by reading a resistance value within a given range directly proportional to water temperature. 3. The con ...

  • A.O. Smith GPDX - page 15

    15 USERS OF THIS APPLIANCE SHOULD BE A W ARE THA T GAS COMPONENTS WEAR OUT OVER A PERIOD OF TIME. THE GAS CARRYING COMPONENTS OF THIS APPLIANCE SHOULD BE INSPECTED FOR PROPER OPERA TION PERIODICALL Y BY A QUALIFIED SERVICE TECHNICIAN. MAIN BURNER Check main burner every 12 months for proper flame characteristics. This is done by removing door(s) on ...

  • A.O. Smith GPDX - page 16

    16 TROUBLE SHOOTING HELP THERMOST A T AND GAS SUPPL Y CHECK A hydrogen sulfide (rotten egg) odor may result if water contains high sulfate and/or minerals. Chlorinating the water supply should minimize the problem, see EXTENDED NON-USE PERIODS. NOTE: Anode rod must remain installed (except for inspection) to avoid shortening tank life. See LIMITED ...

  • A.O. Smith GPDX - page 17

    17 TROUBLE SHOOTING Please check guidelines below . For your safety , water heater service should be performed only by a qualified service technicia n. Read the GENERAL SAFETY INFORMA TION section first. PROBLEM SOLUTION An open earth ground circuit to the 1. Check that the earth ground connection is ignition system. properly connected. 2. Check th ...

  • A.O. Smith GPDX - page 18

    18 TROUBLE SHOOTING (Continued) PROBLEM CAUSE SOLUTION 1) Blower will not run. A) “ON/OFF” control switch turned off. Turn switch to the “ON” position. B) Blower unplugged. Plug blower back into 1 15 V ac. outlet. C) No power at outlet. Repair service to outlet. D) Thermostat defective. Replace thermostat. E) Control harness defective. Repl ...

  • A.O. Smith GPDX - page 19

    19 THIS WARRANTY IS APPLICABLE TO THE ORIGINAL OWNER ONL Y . If the glass lined tank in this water heater shall prove upon examination by A. O. Smith Corporation (the warrantor) to have leaked during the warranty period in normal residential use, due to natural corrosion from potable water therein, the warrantor will furnish the ORIGINAL OWNER a re ...

  • A.O. Smith GPDX - page 20

    20 1 25 SOUTHEAST P ARKWA Y • FRANKLIN, TN 37 068 Phone: 1-800-433-2545 • Fax: 1- 800 - 43 3 -2515 www.aosmithwaterheaters.com / email: parts @hotwater.com ...

Fabbricante A.O. Smith Categoria Water Heater

I documenti che otteniamo dal fabbricante del dispositivoA.O. Smith GPDX possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici A.O. Smith
- manuali per l’uso GPDX
- schede prodotto A.O. Smith
- opuscoli
- o etichette energetiche A.O. Smith GPDX
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso A.O. Smith GPDX.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione A.O. Smith GPDX, manuali di manutenzione, brevi manuali o manuali utente A.O. Smith GPDX. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto A.O. Smith GPDX.

Manuali per l’uso simili

Manuale completo del dispositivo A.O. Smith GPDX, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare A.O. Smith GPDX dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti A.O. Smith GPDX.

Il manuale per l’uso completo A.O. Smith, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale A.O. Smith GPDX - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice A.O. Smith GPDX, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per A.O. Smith GPDX che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo A.O. Smith GPDX - che ci dovrebbe aiutare nei primi passi durante l'uso A.O. Smith GPDX
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del A.O. Smith GPDX
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio A.O. Smith GPDX in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su A.O. Smith GPDX?

Utilizza il modulo sottostante

Se non hai risolto il problema con A.O. Smith GPDX con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con A.O. Smith GPDX è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)