    PLASMA AIR CUTTER 220 VOL T - 36 AMP INVER TER TECHNOLOGY ASSEMBL Y AND OPERA TING INSTR UCTIONS 3491 MISSION OAKS BL VD ., CAMARILLO , CA 93011 VISIT OUR WEB SITE A T HTTP://WWW .HARBORFREIGHT .COM Cop yright © 2004 b y Harbor F reight T ools ® . All r ights reser v ed. No por tion of this manual or any ar twork contained herein may be reproduce ...

  • Chicago Electric 91814 - page 2

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 2 Contents SPECIFICA TIONS ............................................................................ 3 GENERAL SAFETY R ULES ............................................................ 3 SPECIFIC SAFETY R ULES ....................... ...

  • Chicago Electric 91814 - page 3

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 3 SPECIFICA TIONS Cutting Depth 3/8 inch on steel Cutting Current 5 to 36 Amps listed Rated Load V oltage 100 VDC No-load V oltage 200 VDC (maximum) P ower Consumption 220 V A C, 15 Amps, 50/60 Hz, single phase Line Cord 6’ - 9” long ...

  • Chicago Electric 91814 - page 4

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 4 of flammab le liquids, gases, or dust. P ower tools create sparks which ma y ignite the dust or fumes. 3. Keep bystander s, children, and visitors away while operating a power tool. Distractions can cause you to lose control. Protect ...

  • Chicago Electric 91814 - page 5

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 5 13. Remove adjusting keys or wrenches before turning the power tool on. A wrench or a key that is left attached to a rotating par t of the pow er tool ma y result in personal injur y . 14. Do not overreac h. Keep proper footing and bal ...

  • Chicago Electric 91814 - page 6

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 6 SPECIFIC SAFETY R ULES 1. Maintain labels and nameplates on the Air Plasma Cutter . These carr y impor tant inf or mation. If unreadab le or missing, contact Harbor F reight T ools f or a replacement. 2. Maintain a safe working en viro ...

  • Chicago Electric 91814 - page 7

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 7 not possib le, designate someone to ser v e as a fire w atch, equipped with a fire e xtin- guisher , dur ing the cutting process and for at least one half hour after the cutting is completed. • Do not cut on materials havin g a com ...

  • Chicago Electric 91814 - page 8

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 8 • Follo w OSHA guidelines for P er missible Exposure Limits (PEL ’ s) for various fumes and gases. • Fol low the American Conf erence of Gov er nmental Industrial Hygienists recommend a- tions f or Threshold Limit V alues (TL V? ...

  • Chicago Electric 91814 - page 9

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 9 GR OUNDING This Air Plasma Cutter requires a 3-prong, 220 V A C, polarized, twistlock plug (not sup- plied). This plug must be installed by a qualified electrician. W ARNING! Improperl y connecting the grounding wire can result in the ...

  • Chicago Electric 91814 - page 10

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 10 SYMBOLOGY T able B UNP A CKING When unpacking, check to make sure that all the par ts are included. Refer to the Assembly section, and the Assembly Diag rams and P ar ts List on pages 15 & 16. If any par ts are missing or broken, ...

  • Chicago Electric 91814 - page 11

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 11 ASSEMBL Y INSTR UCTIONS 1. Connect a 3-prong, 220 V A C , polarized, twistlock plug (not supplied) to the Line Cord. This plug must be installed b y a qualified electrician. 2. Attach the Pressure Gauge to the Air Regulator (58). The ...

  • Chicago Electric 91814 - page 12

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 12 OPERA TING INSTRUCTIONS SETUP Before beginning, please read and understand the section “Specific Safety Rules” starting on page 6. 1. Mount the metal to be cut to a metal welding-cutting table (not supplied). It should be mounted ...

  • Chicago Electric 91814 - page 13

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 13 DURA TION OF USE (DUTY CYCLE) A void damage to the Cutter b y not leaving it on for more than the prescribed duration of use . The Duration of Use (or Duty Cycle) defines the number of minutes , within a 10 minute per iod, dur ing wh ...

  • Chicago Electric 91814 - page 14

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 14 PR OPER CUTTING TECHNIQUE 14. T o cut efficiently , the follo wing steps must be carefully f ollowed: √ Lightly touc h the Tip to the cutting surface . √ CONT A CT WITH THE WORK SURF A CE MUST BE MAINT AINED OR THE UNIT WIL ...

  • Chicago Electric 91814 - page 15

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 15 INSPECTION, MAINTENANCE, AND CLEANING W ARNING! Make sure the P ower Switc h of the Plasma Cutter is in its “OFF” position and that the tool is unplug ged fr om the electrical outlet before performing any inspec- tion, maintenance ...

  • Chicago Electric 91814 - page 16

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 16 CIRCUIT DIA GRAM PLEASE READ THE FOLLO WING CAREFULL Y THE MANUF A CTURER AND/O R DISTRIBU T OR HAS PRO VIDED THE P AR TS DIA GRAM IN THIS MANU AL AS A REFE RENC E T OOL ONL Y . NEIT HER THE MAN UF A CTUR ER NOR DIST RIB UT OR MAKES A ...

  • Chicago Electric 91814 - page 17

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 17 NO TE : Some par ts are listed and shown for illustration pur poses only and are not av ailable individually as replacement par ts. P AR TS LIST 59 Part Description Qty 1 Housing 1 2 End Cov er , Plastic 2 3 Current Adjusting Knob 1 4 ...

  • Chicago Electric 91814 - page 18

    For technical questions, please call 1-800-444-3353; T roub leshooting section at end of manual. SKU 91814 P AGE 18 NO T SHO WN #54 Grounding Clamp/Cable #58 Air Regulator w/gauge ASSEMBL Y DIA GRAM REV 07/05; 06/06 ...

  • Chicago Electric 91814 - page 19

    If the steps above do not solve the pr oblem or if the repairs in volved are too complex, contact a qualified technician. IMPORT ANT! Be CERT AIN to shut off the Plasma Cutter , and disconnect it from power and air before adjusting, cleaning, or repairing the unit. A technician should dischar ge all capacitors bef ore performing an y internal proc ...

  • Chicago Electric 91814 - page 20

    If the steps above do not solve the pr oblem or if the repairs in volved are too complex, contact a qualified technician. IMPORT ANT! Be CERT AIN to shut off the Plasma Cutter , and disconnect it from power and air before adjusting, cleaning, or repairing the unit. A technician should dischar ge all capacitors bef ore performing an y internal proc ...

  • Chicago Electric 91814 - page 21

    If the steps above do not solve the pr oblem or if the repairs in volved are too complex, contact a qualified technician. IMPORT ANT! Be CERT AIN to shut off the Plasma Cutter , and disconnect it from power and air before adjusting, cleaning, or repairing the unit. A technician should dischar ge all capacitors bef ore performing an y internal proc ...

  • Chicago Electric 91814 - page 22

    If the steps above do not solve the pr oblem or if the repairs in volved are too complex, contact a qualified technician. IMPORT ANT! Be CERT AIN to shut off the Plasma Cutter , and disconnect it from power and air before adjusting, cleaning, or repairing the unit. A technician should dischar ge all capacitors bef ore performing an y internal proc ...

Fabbricante Chicago Electric Categoria Welder

I documenti che otteniamo dal fabbricante del dispositivoChicago Electric 91814 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Chicago Electric
- manuali per l’uso 91814
- schede prodotto Chicago Electric
- opuscoli
- o etichette energetiche Chicago Electric 91814
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Chicago Electric 91814.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Chicago Electric 91814, manuali di manutenzione, brevi manuali o manuali utente Chicago Electric 91814. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Chicago Electric 91814.

Manuale completo del dispositivo Chicago Electric 91814, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Chicago Electric 91814 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Chicago Electric 91814.

Il manuale per l’uso completo Chicago Electric, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Chicago Electric 91814 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Chicago Electric 91814, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Chicago Electric 91814 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Chicago Electric 91814 - che ci dovrebbe aiutare nei primi passi durante l'uso Chicago Electric 91814
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Chicago Electric 91814
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Chicago Electric 91814 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Chicago Electric 91814?

Utilizza il modulo sottostante

Se non hai risolto il problema con Chicago Electric 91814 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Chicago Electric 91814 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)