Manuale per l’uso Lincoln Electric RANGER IM604-B

38 pagine 0.86 mb
Scarica

Vai alla pagina of 38

Summary
  • Lincoln Electric RANGER IM604-B - page 1

    OPERA TOR’S MANUAL Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part. DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT WITHOUT READING THIS MANUAL AND THE SAFETY PRECAUTIONS CONT ...

  • Lincoln Electric RANGER IM604-B - page 2

    FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors. ________________________________________________ ...

  • Lincoln Electric RANGER IM604-B - page 3

    ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards. 4.b. Use suitable clothing made from durable flame-resistant material to protect your skin ...

  • Lincoln Electric RANGER IM604-B - page 4

    FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations. 8.c. Ground the equipment in accordance with the U.S. National Electrical C ...

  • Lincoln Electric RANGER IM604-B - page 5

    iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instruc- tions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suivantes: Sûreté Pour Soudage A L’Arc 1. Protegez-vous contre la secousse électrique: a. Les circuits ? ...

  • Lincoln Electric RANGER IM604-B - page 6

    RANGER 8 LPG Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment. Save this manual and keep it handy for quick refer ...

  • Lincoln Electric RANGER IM604-B - page 7

    vi vi T ABLE OF CONTENTS Page SAFETY PRECAUTIONS .......................................................................................i - iv INTRODUCTORY INFORMATION ............................................................................v GENERAL DESCRIPTION .................................................................................... ...

  • Lincoln Electric RANGER IM604-B - page 8

    1 1 RANGER 8 LPG GENERAL DESCRIPTION The Ranger ™ 8 LPG is a twin-cylinder LPG fuel engine driven multiprocess arc welder and AC power genera- tor. It is built in a heavy gauge steel case for durability on the job site. DESIGN FEA TURES AC/DC STICK WELDING (Constant Current) • AC 40 - 225 Amps • DC 40 - 210 Amps • 100% Duty Cycle on All Set ...

  • Lincoln Electric RANGER IM604-B - page 9

    2 2 RANGER 8 LPG Machine Product Name Ordering Information K1616-1 Description Multi-Purpose Arc Welder with 8,000 watts of Auxiliary Power AC Constant Current 225A / 25V / 100% DC Constant Current 210A / 25V / 100% DC Constant Voltage 200A / 20V / 100% Max. O.C.V. 80V Auxiliary Power Welding Output 8000 Watts, 60 Hz AC 70 Amps @ 115V 35 Amps @ 230 ...

  • Lincoln Electric RANGER IM604-B - page 10

    3 3 RANGER 8 LPG AC STICK / TIG (CC) OUTPUT A 225 OUTPUT RANGE B 50 OUTPUT RANGE A B OUTPUT AMPS OUTPUT VOLTS AC 0 50 100 150 200 250 0 10 20 30 40 50 60 70 80 DC STICK / TIG (CC) OUTPUT OUTPUT AMPS OUTPUT VOLTS DC A 210 OUTPUT RANGE B 50 OUTPUT RANGE A B 0 50 100 150 200 250 300 350 0 10 20 30 40 50 60 70 80 CV OUTPUT RANGE 0 50 100 150 200 250 30 ...

  • Lincoln Electric RANGER IM604-B - page 11

    4 4 RANGER 8 LPG OPTIONAL EQUIPMENT (Field Installed) Four Wheel Undercarriage (K933-1) - Allows move- ment of the Ranger 8 by hand without lifting. Easily assembles to the Ranger 8. Includes two rugged, hard molded wheels and two durable, two ply nylon 4.80/4.00-8 pneumatic tires rated at 30 psi. The spring loaded handle provides convenient, comfo ...

  • Lincoln Electric RANGER IM604-B - page 12

    5 5 RANGER 8 LPG RECOMMENDED EQUIPMENT STICK Accessory Kit (K710) which includes: • Electrode Holder & Cable • Work Clamp & Cable • Headshield Remote Control Receptacle Kit (K892-1), and Remote Control Kit (K857) are optional for remote current control. TIG Magnum™ TIG Torch Magnum Parts Kit and Argon Gas TIG Module (K930-1) Contact ...

  • Lincoln Electric RANGER IM604-B - page 13

    6 6 RANGER 8 LPG INST ALLA TION INSTRUCTIONS Safety Precautions Machine Grounding Because this portable engine driven welder or gener- ator creates it’s own power, it is not necessary to con- nect it’s frame to an earth ground, unless the machine is connected to premises wiring (your home, shop, etc.). To prevent dangerous electric shock, other ...

  • Lincoln Electric RANGER IM604-B - page 14

    7 7 RANGER 8 LPG • The stem of the cylinder valve and where the valve is attached to the top of the cylinder. • All other fittings on top of the fuel cylinder. If growing bubbles appear, there is a leak. Re-tighten connection or replace defective component. Retest to make sure that there is no leak. Leak test must be performed each time the fue ...

  • Lincoln Electric RANGER IM604-B - page 15

    8 8 RANGER 8 LPG Battery Connections This welder is shipped with the negative battery cable disconnected. Make sure that the Engine Switch is in the “OFF” position and attach the disconnected cable securely to the negative battery terminal before attempting to operate the machine. If the battery is discharged and does not have enough power to s ...

  • Lincoln Electric RANGER IM604-B - page 16

    9 9 RANGER 8 LPG Angle of Operation Internal combustion engines are designed to run in a level condition which is where the optimum perfor- mance is achieved. The maximum angle of operation for the engine is 25 degrees from horizontal in any direction. If the engine is to be operated at an angle, provisions must be made for checking and maintain- i ...

  • Lincoln Electric RANGER IM604-B - page 17

    10 10 RANGER 8 LPG Connection of the LN-7 to the Ranger 8 a. Shut the welder off. b. Connect the LN-7 and the K240 contactor kit per instructions on the connection diagram S17742 (can be found in the back of this manual). c. Place the “RANGE” switch to the “WIRE FEED” position and the “POLARITY” switch to the desired polarity. d. Place ...

  • Lincoln Electric RANGER IM604-B - page 18

    a. Welding When the electrode touches the work, the welding arc is initiated and the engine accelerates to full speed. After welding ceases (and no auxiliary power is being drawn), the engine will return to low idle after approximately 10 to 14 seconds. b. Auxiliary Power With the engine running at low idle and auxiliary power for lights or tools i ...

  • Lincoln Electric RANGER IM604-B - page 19

    12 12 RANGER 8 LPG After running at high engine speed for 10-14 seconds, the engine will go to low idle. Allow the engine to warm up by letting it run at low idle for a few minutes. Stopping the Engine Remove all welding and auxiliary power loads and allow engine to run at low idle speed for a few minutes to cool the engine. NOTE: Backfiring may oc ...

  • Lincoln Electric RANGER IM604-B - page 20

    13 13 RANGER 8 LPG Wire Feed Welding Processes (Constant Voltage) The only Innershield ® electrode recommended for use with the Ranger 8 is NR ® -211-MP. The electrode sizes and welding ranges that can be used with the Ranger 8 are shown in the following table: Diameter Wire Speed Approximate (in.) Range In./Min. Current Range .035 80 - 110 75A t ...

  • Lincoln Electric RANGER IM604-B - page 21

    14 14 RANGER 8 LPG The current rating of any plug used with the system must be at least equal to the current load through the associated receptacles (see tables below). Do not attempt to connect power receptacles in parallel. * Maximum current draw from each 115V GFCI Duplex receptacle is 20 amps. 115/230 Volt Dual Voltage Receptacle The 115/230 vo ...

  • Lincoln Electric RANGER IM604-B - page 22

    15 15 RANGER 8 LPG 1. Install a double pole, double throw switch between the power company meter and the premises disconnect. Switch rating must be the same or greater than the customer’s premises disconnect and service overcurrent protection. 2. Take necessary steps to assure load is limited to the capacity of the Ranger 8 by installing a 35 amp ...

  • Lincoln Electric RANGER IM604-B - page 23

    16 16 RANGER 8 LPG CAUTION Certain Electrical devices cannot be powered by the RANGER 8 LPG. See Table A.2. TABLE A.2 ELECTRICAL DEVICE USE WITH THE RANGER 8 LPG. Type Common Electrical Devices Possible Concerns Resistive Heaters, toasters, incandescent NONE light bulbs, electric range, hot pan, skillet, coffee maker. Capacitive TV sets, radios, mi ...

  • Lincoln Electric RANGER IM604-B - page 24

    17 17 RANGER 8 LPG MAINTENANCE Safety Precautions Read the Safety Precautions in the front of this manu- al and the engine instruction manual before working on this machine. Keep all equipment safety guards, covers, and devices in position and in good repair. keep hands, hair, clothing, and tools away from gears, fans, and all other moving parts wh ...

  • Lincoln Electric RANGER IM604-B - page 25

    18 18 RANGER 8 LPG 1. When replacing, jumping, or otherwise connecting the battery to the battery cables, the proper polarity must be observed. Failure to observe the proper polarity could result in damage to the charging circuit. The positive (+) battery cable has a red terminal cover. 2. If the battery requires charging from an external charger, ...

  • Lincoln Electric RANGER IM604-B - page 26

    19 TROUBLESHOOTING 19 RANGER 8 LPG TROUBLE A. No welder or output power. B. Engine will not idle down to low speed. C. Engine will not go to high idle when attempting to weld. CAUSE 1. Open in miscellaneous leads. 2. Open lead in flashing or field circuit. 3. Faulty rotor. 4. Faulty Potentiometer (R1). 5. Faulty stator Field winding. 6. Faulty Fiel ...

  • Lincoln Electric RANGER IM604-B - page 27

    20 TROUBLESHOOTING 20 RANGER 8 LPG TROUBLE D. Engine will not go to high idle when using auxiliary power. E. Engine will not crank or is hard to crank. F. Engine shuts down. G. Engine does not develop full power. H. Engine is hard to start. CAUSE 1. No voltage signal from the current sensor. 2. Auxiliary power load less than 100 to 150 watts. 3. Fa ...

  • Lincoln Electric RANGER IM604-B - page 28

    21 WIRING DIAGRAM 21 RANGER 8 LPG STARTER CR1 STARTER SOLENOID 12 VOLT IDLER SOLENOID 213 BATTERY AC AC B+ SWITCH REGULATOR FLYWHEEL ALTERNATOR B- HOUR METER 5E 5D S4 224B 224 213 "S4" SHOWN IN "AUTO" POSITION ENGINE COMPONENTS 224A 1 2 3 CONNECTOR PIN NUMBERS: 7 6 12 1 2 3 4 J1 LEAD COLOR CODE: B = BLACK R = RED W = WHITE N.A. ...

  • Lincoln Electric RANGER IM604-B - page 29

    22 DIAGRAMS 22 RANGER 8 LPG STARTER CR1 STARTER SOLENOID 12 VOLT IDLER SOLENOID 213 BATTERY AC AC B+ SWI TCH REGULATOR FLYWHEEL ALTERNATOR B- HOUR METER 5E 5D S4 224B 224 213 "S4" SHOWN IN "AUTO" POSITION ENGINE COMPONENT S 224A 1 2 3 CONNECTOR PIN NUMBERS: 7 6 12 1 2 3 4 J1 N.A. B J5 SOLENOID FUEL SHUTOFF OIL PRESSURE TERMINAL ...

  • Lincoln Electric RANGER IM604-B - page 30

    23 CONNECTION DIAGRAMS 23 RANGER 8 LPG CONNECTION OF RANGER 8 TO LN-7 & K240 CONT ACTOR KIT WARNING: Turn the power off when making connections. N.A. Use power source polarity switch to set for desired electrode polarity. Position the output selector switch on the power source to the CV position. N.B. 3 conductor #16 power cord physically suita ...

  • Lincoln Electric RANGER IM604-B - page 31

    9.29 21.21 21.95 43.80 17.00 26.59 30.28 19.11 9.31 M17215-4 CRM28731 9.09 9.09 UNDERCARRIAGE MOUNTING HOLES 42.25 42.00 CENTER OF GRAVITY WITH OIL IN ENGINE AND FULL FUEL TANK. 11.31 FOR OIL FILTER REMOVAL 8.80 30.00 2.75 24 DIMENSION PRINT 24 RANGER 8 LPG DIMENSION PRINT - Ranger 8 LPG (Kohler) ...

  • Lincoln Electric RANGER IM604-B - page 32

    NOTES RANGER 8 LPG ...

  • Lincoln Electric RANGER IM604-B - page 33

    NOTES RANGER 8 LPG ...

  • Lincoln Electric RANGER IM604-B - page 34

    NOTES RANGER 8 LPG ...

  • Lincoln Electric RANGER IM604-B - page 35

    There is a 10% discount on all orders of $50.00 or more for shipment at one time to one location. Orders of $50 or less before discount or orders outside of North America must be prepaid with charge, check or money order in U .S. Funds Only. Prices include shipment by 4 th Class Book Rate for U.S.A. Mainland Only. Please allow up to 4 weeks for del ...

  • Lincoln Electric RANGER IM604-B - page 36

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES. SE RECOMIENDA LEER Y ENTENDER LAS INSTRUCCIONES DEL F ABRICANTE PARA EL ...

  • Lincoln Electric RANGER IM604-B - page 37

    W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR. ● Keep your head out of fumes. ● Use ventilation or exhaust to remove fumes f ...

  • Lincoln Electric RANGER IM604-B - page 38

    • Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.lincolnelectric.com • World's Leader in Welding and Cutting Products • ...

Fabbricante Lincoln Electric Categoria Welder

I documenti che otteniamo dal fabbricante del dispositivoLincoln Electric RANGER IM604-B possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Lincoln Electric
- manuali per l’uso RANGER IM604-B
- schede prodotto Lincoln Electric
- opuscoli
- o etichette energetiche Lincoln Electric RANGER IM604-B
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Lincoln Electric RANGER IM604-B.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Lincoln Electric RANGER IM604-B, manuali di manutenzione, brevi manuali o manuali utente Lincoln Electric RANGER IM604-B. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Lincoln Electric RANGER IM604-B.

Manuali per l’uso simili

Manuale completo del dispositivo Lincoln Electric RANGER IM604-B, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Lincoln Electric RANGER IM604-B dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Lincoln Electric RANGER IM604-B.

Il manuale per l’uso completo Lincoln Electric, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Lincoln Electric RANGER IM604-B - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Lincoln Electric RANGER IM604-B, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Lincoln Electric RANGER IM604-B che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Lincoln Electric RANGER IM604-B - che ci dovrebbe aiutare nei primi passi durante l'uso Lincoln Electric RANGER IM604-B
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Lincoln Electric RANGER IM604-B
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Lincoln Electric RANGER IM604-B in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Lincoln Electric RANGER IM604-B?

Utilizza il modulo sottostante

Se non hai risolto il problema con Lincoln Electric RANGER IM604-B con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Lincoln Electric RANGER IM604-B è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)