Manuale per l’uso Mitsubishi Electronics W3-002-SLSUPS-002A

17 pagine 0.23 mb
Scarica

Vai alla pagina of 17

Summary
  • Mitsubishi Electronics W3-002-SLSUPS-002A - page 1

    W3-002-SLSUPS-002A REMOTE STATUS ALARM PANEL INSTALLATION/INSTRUCTION MANUAL RSAP Mitsubishi Electric Automation, Inc. UPS Group ...

  • Mitsubishi Electronics W3-002-SLSUPS-002A - page 2

    10/13/0 4 1 93120-MAN07 Table of Contents Physical Charact eristics..................................................................... 2 Installation inst ructions...................................................................... 2 Operating instructions........................................................................ 3 Remote Monitor ...

  • Mitsubishi Electronics W3-002-SLSUPS-002A - page 3

    10/13/0 4 2 93120-MAN07 Physical Characteristics Weight: 10lbs (4.5 kgs.) Height: 81/4 inches (210 mm) Width: 8 5/16 inches (211 mm ) Depth: 4 5/16 inches (110 mm) Installation 1. Locate the area where the Remote Status Alarm Panel (RSAP) will be installed. The monitor should be within 300 feet (91 meters) of the UPS. 2. Mount the monitor to the wa ...

  • Mitsubishi Electronics W3-002-SLSUPS-002A - page 4

    10/13/0 4 3 93120-MAN07 Operating Instructions ALARM SILENCE pushbutton is used to silence the alarm. MONITOR RESET pushbutton is used to reset the RSAP’s UPS FAULT alarm. The monitor will alarm again if the alarm condition is still present following the RESET. Monitor TEST pushbutton is used to check the operation of all LED's and the audib ...

  • Mitsubishi Electronics W3-002-SLSUPS-002A - page 5

    10/13/0 4 4 93120-MAN07 UPS FAULT OVERLOAD INPUT FAILURE BATTERY LOW VOLTAGE ALARM SILENCE INTERNAL MONITOR BATTERY OK MONITOR RESET MONITOR TEST ALARM SILENCE INTERNAL MONITOR BATTERY TEST BYPASS INPUT OUTPUT 1. RECT IFIER ON (GREE N LED) 6. AC INPUT ON (GREEN LED) 7. UPS FAULT (RED LED) 8. OVERLOAD (RED LED) 9. INPUT FAILURE (RED LED) 10. BATTERY ...

  • Mitsubishi Electronics W3-002-SLSUPS-002A - page 6

    10/13/0 4 5 93120-MAN07 UPS FAULT OVERLOAD INPUT FAILURE BATTERY LOW VOLTAGE ALARM SILENCE INTERNAL MONITOR BATTERY OK MONITOR RESET MONITOR TEST ALARM SILENCE INTE RNAL M ONIT OR BATTERY TEST BYPASS INPUT OUTPUT 1. RECTIFIER ON (GREEN LED) 6. AC INPUT ON (GREEN LED) 7. UPS FAULT (RED LED) 8. OVERLO AD (RED LED) 9. INPUT FAILURE (RED LED) 10. BATTE ...

  • Mitsubishi Electronics W3-002-SLSUPS-002A - page 7

    10/13/0 4 6 93120-MAN07 -AC INPUT L1 (OPTION) -BYPASS (CLOSES WHEN ON BYPASS) -BYPASS COMMON -INVERTER (CLOSES WHEN INVERTER IS RU NNING) -INVERTER COMMON -ON BATTERIES (CLOSES WHEN ON BATTERIES) -BATTERY COMMON -RECTIFIER (CLOSES WHEN RECTIFIER IS RUNNING) -RECTIFIER COMMON -UPS FAILURE (CLOSES ON UPS FAILUR E) -UPS COMMON -LOW BATTERY (CLOSES WH ...

  • Mitsubishi Electronics W3-002-SLSUPS-002A - page 8

    10/13/0 4 7 93120-MAN07 -BYPASS -BYPASS COMMON -INVERTER (CLOSES WHEN INVERTER IS RUNNING) -INVERTER COMMON -ON BATTERIES (CLOSES WHEN ON BATTERIES) -BATTERY COMMON -RECTIFIER (CLOSES WHEN RECTIFIER IS RUNNING) -RECTIFIER COMMON -UPS FAILURE (CLOSE S ON UPS FAILURE) -UPS COMMON -LOW BATTERY (CLOSES WH EN BATTERIES ARE LOW) -LOW BATTERY COMMON -OVER ...

  • Mitsubishi Electronics W3-002-SLSUPS-002A - page 9

    10/13/0 4 8 93120-MAN07 2 AC INPUT L1 (OPTION) 3 BYPASS 4 BYPASS COMMON 5 INVERTE R 6 INVERTER COMMON 7 ON BATTERIES 8 BATTERY CO M MON 9 RECTIFIER 10 RECTIFIER COMMON 11 UPS FAILU R E 12 UPS COMMON 13 LOW BAT TERY 14 LOW BATTERY COMMON 15 OVERLOAD 16 OVERLOAD COMMON 1 AC INPUT L1 (OPTION) BATTERY ARRANGEMENT TERMINAL BLOCK LABELS 6" 6" . ...

  • Mitsubishi Electronics W3-002-SLSUPS-002A - page 10

    10/13/0 4 9 93120-MAN07 TERMINAL BLOCKS LABELS 6" 6" .312"Ø MOUNT HOLES CIRCUIT BOARD BATTERY HOLDER FIGURE 3.1 (INTERNAL POWER SUPPLY / HARDWIRE OPTION) BATTERY ARRANGEMENT 11 RECTIFIER 15 LOW BATTERY 14 UPS COMMON 13 UPS FAILURE 17 OVERLOAD 18 OVERLOAD COMMON 16 LOW BATTERY COMMON 12 RECTIFIER COMMON 3 GROUND 7 INVERTER 6 BYPASS C ...

  • Mitsubishi Electronics W3-002-SLSUPS-002A - page 11

    10/13/0 4 10 93120-MAN07 BATTERY L O W VOLTA G E ALARM SILEN C E INTERNAL MON IT OR BATTERY O K UPS FA U LT OVERLOA D INPUT FAI L U RE ALARM SILEN C E INTERNAL MON IT OR BATTERY TE ST MO N I T O R RESET MONITOR TE ST OUTP U T BY PA S S INPUT 1.5 0" 1.5 0" 1.5 0" 4.0 0" 6.00" 6.00" 1.0 0" 1.00" Ø 0.31 2 M OUN ...

  • Mitsubishi Electronics W3-002-SLSUPS-002A - page 12

    10/13/0 4 0 93120-MAN07 Mitsubishi Electric Automa tion, Inc. Date Draw n by Dwg No. Page 1 2 3 45 6 78 9 A B C D Dwg No. 21 16 22 14 13 19 20 18 17 15 14 13 12 11 10 9 8 7 5 4 3 U-23026 Output Overload Selec tab le Item 5 Output Overloa d Common Com mon Batter y L ow Selec tab le Item 6 Low Battery Comm on UPS Failure UPS Failure Common Com mon Co ...

  • Mitsubishi Electronics W3-002-SLSUPS-002A - page 13

    10/13/04 0 93120-MAN07 Mitsubishi Electric Automation, Inc. Date Draw n by Dwg No. Page 1 2 3 45 6 78 9 A B C D Dwg No. 35 34 33 30 29 28 27 26 25 24 22 21 15 14 13 12 11 10 9 8 7 5 4 3 U-23028 Output Overload Output Overloa d Common Com mon Batter y L ow Low Battery Common Com mon UPS Failure UPS Failure Common Com mon Con vert er O perati on Rect ...

  • Mitsubishi Electronics W3-002-SLSUPS-002A - page 14

    10/13/04 0 93120-MAN07 Mitsubishi Electric Automa tion, Inc. Date Draw n by Dwg No. Page 1 2 3 45 6 78 9 A B C D Dwg No. 18 17 16 15 6 5 14 13 12 11 8 7 16 15 14 13 12 11 10 9 8 7 6 5 U-23C012 Output Overload Common Output Overloa d Batter y L ow Common Low Battery Comm on Batter y L ow Low Battery UPS Failure Common UPS Failure Comm on UPS Failure ...

  • Mitsubishi Electronics W3-002-SLSUPS-002A - page 15

    10/13/04 0 93120-MAN07 14 AW G shielded w i re recommended Mitsubishi Electric Automa tion, Inc. Date Draw n by DWG No. Page 1 2 3 45 6 78 9 A B C D DWG No. 26 25 22 21 38 37 18 17 14 13 10 9 U-23D019 Overload Common Overload Batter y L ow Voltage Common Batter y L ow Voltage Tota l Alar m Common Tota l Alar m Conve rter (Re ctifier ) Operati on Co ...

  • Mitsubishi Electronics W3-002-SLSUPS-002A - page 16

    10/13/04 1 93120-MAN07 Mitsubishi Electric Automation, Inc. Date Draw n by Dwg No. Page 1 2 3 45 6 78 9 A B C D Dwg No. 35 34 33 30 29 28 27 26 25 24 22 21 15 14 13 12 11 10 9 8 7 5 4 3 U-97017 Output Overload Output Overloa d Common Com mon Batter y L ow Low Battery Common Com mon UPS Failure UPS Failure Common Com mon Con vert er O perati on Rect ...

  • Mitsubishi Electronics W3-002-SLSUPS-002A - page 17

    10/13/04 2 93120-MAN07 14 awg shiel de d wire recomm ended Mitsubishi Electric Automation, Inc. Date Draw n by Dwg No. Page 1 2 3 45 6 78 9 A B C D Dwg No. 28 27 26 25 16 15 24 23 22 21 20 19 U-98015 Output Overload Common Output Overload Batter y L ow Common Batter y low UPS Failure Common UPS Failure Rectif ier Ope ratio n Common Batt ery Oper at ...

Fabbricante Mitsubishi Electronics Categoria Automobile Alarm

I documenti che otteniamo dal fabbricante del dispositivoMitsubishi Electronics W3-002-SLSUPS-002A possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Mitsubishi Electronics
- manuali per l’uso W3-002-SLSUPS-002A
- schede prodotto Mitsubishi Electronics
- opuscoli
- o etichette energetiche Mitsubishi Electronics W3-002-SLSUPS-002A
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Mitsubishi Electronics W3-002-SLSUPS-002A.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Mitsubishi Electronics W3-002-SLSUPS-002A, manuali di manutenzione, brevi manuali o manuali utente Mitsubishi Electronics W3-002-SLSUPS-002A. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Mitsubishi Electronics W3-002-SLSUPS-002A.

Manuale completo del dispositivo Mitsubishi Electronics W3-002-SLSUPS-002A, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Mitsubishi Electronics W3-002-SLSUPS-002A dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Mitsubishi Electronics W3-002-SLSUPS-002A.

Il manuale per l’uso completo Mitsubishi Electronics, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Mitsubishi Electronics W3-002-SLSUPS-002A - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Mitsubishi Electronics W3-002-SLSUPS-002A, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Mitsubishi Electronics W3-002-SLSUPS-002A che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Mitsubishi Electronics W3-002-SLSUPS-002A - che ci dovrebbe aiutare nei primi passi durante l'uso Mitsubishi Electronics W3-002-SLSUPS-002A
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Mitsubishi Electronics W3-002-SLSUPS-002A
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Mitsubishi Electronics W3-002-SLSUPS-002A in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Mitsubishi Electronics W3-002-SLSUPS-002A?

Utilizza il modulo sottostante

Se non hai risolto il problema con Mitsubishi Electronics W3-002-SLSUPS-002A con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Mitsubishi Electronics W3-002-SLSUPS-002A è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (1)

Оксана

При использовании духовки в режиме Conventional, предполагающий только верхний и нижний нагрев, все равно работает обдув из-за чего сверху все гори, а внутри не пропекается. Информации в инструкции не нашла.