Manuale per l’uso Metrologic Instruments MS7120

48 pagine 1.77 mb
Scarica

Vai alla pagina of 48

Summary
  • Metrologic Instruments MS7120 - page 1

    METROLOGIC INSTRUMENTS, INC. MS7120 Orbit ® Presentation Laser Scanner Installation and User’s Guide ...

  • Metrologic Instruments MS7120 - page 2

    Copyright © 2008 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or b y any means without prior written consent, except by reviewer, who may quote br ief passages in a review, or provided for in the Copyright Act of 1976. Trademarks Metrologic is a registered trademark ...

  • Metrologic Instruments MS7120 - page 3

    ii T ABLE OF C ONTENTS Introduction Product Over view ............................................................................................. 1 Scanner and A ccessori es ................................................................................. 2 Scanner Comp onents ...................................................................... ...

  • Metrologic Instruments MS7120 - page 4

    iii T ABLE OF C ONTENTS Default Settings - Comm unication Para meters................................................... 25 Scanner Confi guratio n .................................................................................... 30 Configurati on Modes ...................................................................................... 30 Bar ...

  • Metrologic Instruments MS7120 - page 5

    1 I NTRODUCTION Orbit ® is an aggressive, omnidirectiona l laser bar code scanner idea l for use in retail, convenience, liquor and specialty stores Designed to be light weight and rugged, Orbit’s small size makes it idea l for applicati ons where counter space is limited. It’s unique contoured shap e allows it to be picked-up and us ed as a h ...

  • Metrologic Instruments MS7120 - page 6

    2 I NTRODUCTION Scanner and Accessories B ASIC K IT C OMPONENTS Part No. Description MS7120 Orbit Presentation Laser Bar Code Scan ner 00-02282 x MS7120 Orbit Presentation Laser Bar Co de Scanner Installation and User’s Guide 00-02407 x MetroSelect ® Configurati on Guide * Guides also available for dow nload at www.metrologic.com. O PTIONAL A CC ...

  • Metrologic Instruments MS7120 - page 7

    3 I NTRODUCTION Scanner and Accessories O PTIONAL A CCESSORIES Part No. Description MVC** RS485 S Applications Metrologic Voltage Converter Cabl e ±12VDC to +5.2VDC ** Contact a Metrologic customer service representative for additi onal information on the MVC cable series an d the host connections available. 59-59002x-3 Keyboard Wedge Po werLink C ...

  • Metrologic Instruments MS7120 - page 8

    4 I NTRODUCTION Scanner Components I TEM N O D ESCRIPTION 1 White LED ( see page 12 ) 2 Blue LED ( see page 12 ) 3 Red Output Window (Laser Aperture) 4 Speaker ( see page 12 ) 5 Pin Hole for Cable Release 6 10-Pin RJ45, Female Socket ( see page 33 ) 7 Adjustable Scan Head, 30° Figure 1. Scanner Components Cable Removal 1. Locate the small ‘pin-h ...

  • Metrologic Instruments MS7120 - page 9

    5 I NTRODUCTION Caution and Serial Number Labels Figure 3. Labeling Locations on the Bottom of the Scanner and Exa mples Caution To maintain compliance w ith applicable standards, all cir cuits connected to the scanner must meet the requirements for SELV (S afety E xtr a L ow V oltage) according to EN/IEC 60950-1. To maintain compliance w ith stand ...

  • Metrologic Instruments MS7120 - page 10

    6 Figure 5 Figure 7 Figure 6 Figure 8 I NTRODUCTION Mounting Specifications Optional Wall/Counter Mount Item Description Qty. a. Locking Plate, MLPN 50-50302 1 b. Base Cover, MLPN 50-50301 1 c. #7 x 1.00" Wood Screw, MLP N 18-18013 3 d. M3 x 8 mm Flathead Screw, MLPN 18-18004 4 Figure 4. Kit Components 1. Drill three #39 pilot holes. Note the ...

  • Metrologic Instruments MS7120 - page 11

    7 I NSTALLATION RS232, Light Pen Emulation 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS7120. 3. Connect the 9-pin female end of the PowerLink cable to the host device. 4. Plug the external power supply int o the power jack on the PowerLink cable. Check the AC input requirement ...

  • Metrologic Instruments MS7120 - page 12

    8 I NSTALLATION RS485 S 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the MVC cable into the 10-pin socket on the MS7120. 3. Connect the other end of the MVC cable to the host device. 4. Turn on the host device. When the scanner first receives po wer, the blue and white LED will toggle on and off then the scanner will beep once. ...

  • Metrologic Instruments MS7120 - page 13

    9 I NSTALLATION Keyboard Wedge 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS7120. 3. Disconnect the keyboard from the host device. 4. Connect the “Y” end of the PowerLink cable to the keyboard an d the keyboard port on the host PC. If necessary use the male/female adapter c ...

  • Metrologic Instruments MS7120 - page 14

    10 I NSTALLATION Stand-Alone Keyboard 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the PowerLink cable into the 10-pin socket on the MS7120. 3. Connect the other end of the PowerLink cable to the keyboard port on the host device. 4. Plug the external power supply int o the power jack on the PowerLink cable. Check the AC input re ...

  • Metrologic Instruments MS7120 - page 15

    11 I NSTALLATION Full Speed or Low Speed USB 1. Turn off the host device. 2. Plug the male 10-pin RJ45 end of the USB cable into the 10-pin socket on the MS7120. 3. Plug the other end of the USB interface cable into the host device’s USB port. 4. Turn on the host device. When the scanner first receives power, the blue and white LED will toggle on ...

  • Metrologic Instruments MS7120 - page 16

    12 S CANNER O PERATION Audible Indicators When the MS7120 is in operation, it pr ovid es audible feedback to indic ate the status of the scanner. Eight settings are available for the tone of the beep (normal, six alternate tones and no tone). For instructio ns on how to change the tone of the beeper, refer to the MetroS elect Configuration Guide (0 ...

  • Metrologic Instruments MS7120 - page 17

    13 S CANNER O PERATION Visual Indicators The MS7120 is equipp ed with a blue and a white LED that indicates the scanner’s state and the status of the current scan wh en the unit is in operation. Figure 14. LED Location No LEDs The LEDs will not be illumi nated if the sca nner is not receiving po wer from the host or transformer. Steady Blue When ...

  • Metrologic Instruments MS7120 - page 18

    14 S CANNER O PERATION Failure Mode Indicators Flashing Blue with One Razzberry Tone This indicates that the scanner has experien ced a laser subsystem failure. Return the unit to an authoriz ed service center for repair. Synchronized Flashin g of B lu e and Whit e wi th Two Razzberry T one s This indicates that the scanner has experien ced a motor ...

  • Metrologic Instruments MS7120 - page 19

    15 S CANNER O PERATION Depth of Field Specifications* Normal Scan Zone Specifications are based o n a 0.33 mm (13 mil) bar code. Figure 15. MS7120 Normal Depth of Field Reduced Scan Zone Specifications are based o n a 0.33 mm (13 mil) bar code. Figure 16. MS7120 Reduced Dep th of Field * All specifications are subj ect to change w ithout notice. ...

  • Metrologic Instruments MS7120 - page 20

    16 S CANNER O PERATION Depth of Field by Bar Code Element Width* Normal Scan Zone M INIMUM B AR C ODE E LEMENT W IDTH A B C D E F G H J K mm .13 - - - .19 - .25 .33 - .66 mils 5.2 - - - 7.5 - 10 13 - 26 Figure 17. Normal Scan Zone by Bar Code Element W idth * All specifications are subj ect to change w ithout notice. ...

  • Metrologic Instruments MS7120 - page 21

    17 S CANNER O PERATION Depth of Field by Bar Code Element Width* Reduced Scan Zone M INIMUM B AR C ODE E LEMENT W IDTH A B C D E F G H J K mm - .15 - - .19 - .25 .33 - .66 mils - 5.7 - - 7.5 - 10 13 - 26 Figure 18. Reduced Scan Zone by Bar Code Ele ment Width * All specifications are subj ect to change w ithout notice. ...

  • Metrologic Instruments MS7120 - page 22

    18 T ROUBLESHOOTING G UIDE The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-MET RO or 1- 800-436-3876 to preserve the l imited warranty terms on page 38. Symptoms Possible Cause(s) Solution All Interfaces During power up the unit beeps three times. There is a non-volatile RAM failure. Contact a Met ...

  • Metrologic Instruments MS7120 - page 23

    19 T ROUBLESHOOTING G UIDE Symptoms Possible Cause(s) Solution All Interfaces The unit is trying to scan a particular symbology that is not enabled. UPC/EAN, Code 39, Interleaved 2 of 5, Code 93, Code 128 and Codabar are enabled by default. Verify that the type of bar code being read has been selecte d The unit powers up but does not scan and/or be ...

  • Metrologic Instruments MS7120 - page 24

    20 T ROUBLESHOOTING G UIDE Symptoms Possible Cause(s) Solution All Interfaces The bar code may have been printed incorrectly. Check if it is a check digit, character or border problem. The scanner is not configured correctly for the type of bar code. Check if check digits are set properly. Scanner beeps at some bar codes and NOT for others of the s ...

  • Metrologic Instruments MS7120 - page 25

    21 T ROUBLESHOOTING G UIDE Symptoms Possible Cause(s) Solution RS232 Only The host is receiving data but the data does not look correct. The scanner and host may not be configured for the same interface. Check that the scanner and the host are configured for the same interface. Characters are being dropped. The inter character delay needs to be add ...

  • Metrologic Instruments MS7120 - page 26

    22 D ESIGN S PECIFICATIONS MS7120 Operational Light Source: V isible L aser D iode (VLD) @ 650 nm Laser Power: Less than 1 mW average Normal Depth of Field: 0 mm – 215 mm Reduced Depth of Field: 0 mm – 190 mm 0.33 mm (13 mil) bar code Scan Speed: 1120 scan lines per second No. of Scan Lines: 20 Motor Speed: 3360 RPM Min Bar Width: 0.13 mm (5.0 ...

  • Metrologic Instruments MS7120 - page 27

    23 D ESIGN S PECIFICATIONS MS7120 Electrical Voltage Supply: 5VDC ± 0.25V Operating Power: 0.9 W Standby Power: 0.85 W Operating Current: 180 mA typical at 5VDC Standby Current: 170 mA typical at 5VDC DC Transformers: Class II; 5.2VDC @ 1A For regulatory compliance inf ormation, see pages 35 - 37. Environmental Operating Temperature: -20°C to 40? ...

  • Metrologic Instruments MS7120 - page 28

    24 A PPLICATIONS AND P ROTOCOLS The model number on each scann er includes the scanner number a nd factory default communications proto col. S CANNER V ERSION I DENTIFIER C OMM UNIC ATION P ROTOCOL ( S ) 38 RS232 Low Speed USB, Keyboard Emulation or Serial Emulation 41 Full RS232C/Light Pen Emulat ion 47 Keyboard Wedge, Stand-Alone Ke yboard and RS ...

  • Metrologic Instruments MS7120 - page 29

    25 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS Many functions of the scanner can be "config u red" - that is enabled or disabled. The scanner is shipped from the factor y c onfigured to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an asterisk is not in ...

  • Metrologic Instruments MS7120 - page 30

    26 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT RS232 L IGHT P EN RS485 S KBW USB Expanded ID “]e0” *      RSS Limited Enable      RSS Limited ID “]e0” *      RSS Limited App ID “01” *      RSS Limited Check Digit *      Bars High as Code 3 ...

  • Metrologic Instruments MS7120 - page 31

    27 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT RS232 L IGHT P EN RS485 S KBW USB Transmit UPC-A Check Digit *      Transmit UPC-E Check Digit      Expand UPC-E      Convert UPC-A to EAN-13     Transmit Lead Zero on UPC-E      Convert EAN-8 to EAN-13  ...

  • Metrologic Instruments MS7120 - page 32

    28 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT RS232 L IGHT P EN RS485 S KBW USB Nixdorf ID    LRC Enabled    UPC Prefix    UPC Suffix    Transmit AIM ID Characters    STX Prefix    ETX Suffix    Carriage Return *    Line Feed - disable d by default in K ...

  • Metrologic Instruments MS7120 - page 33

    29 D EFAULT S ETTINGS - C OMMUNICATION P ARAMETERS P ARAMETER D EFAULT RS232 L IGHT P EN RS485 S KBW USB Supplements are not Required *      Two Digit Redundancy *      Five Digit Redundancy      100 msec to Find Supplement Configurable in 100msec step s (MAX 800 msec) *      Coupon Code 1 ...

  • Metrologic Instruments MS7120 - page 34

    30 S CANNER C ONFIGURATION C ONFIGURATION M ODES The MS7120* Series scanner has three modes of configuration. • Bar Codes The MS7120 can be configur ed by scanning the bar codes included in the MetroSelect Configuration Guide ( MLPN 00-02407). These manuals can b e downloaded FREE of charge from Metrolog ic’s website (www.metrologic.com). • M ...

  • Metrologic Instruments MS7120 - page 35

    31 U PGRADING THE F IRMWARE The MS7120 is part of Metrologic's line of scanners with flash upgrad eable firmware. The upgrade process requir es, a new firmware file supplied to the customer by a customer service representativ e  and Metrologic's MetroSet 2 software  . A personal computer running Windo ws 95 or greater with an ava ...

  • Metrologic Instruments MS7120 - page 36

    32 S CANNER AND C ABLE T ERMINATIONS Scanner Pinout Connections The MS7120 scanner interfaces terminate to a 10-pin modular socket. The serial number label i ndicates the interface enabled when the scanner is shipped from the factory. Figure 19. MS7120- 47 Keyb oard Wedge and Stand-Alone Keyb oard MS7120- 41 RS232C and Light Pen Emula tion Pin Func ...

  • Metrologic Instruments MS7120 - page 37

    33 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) “Standard” PowerLink Cable MLPN 59-59000 x -3 straight Pin Function 1 Shield Ground 2 RS23 2 Transmit Output 3 RS23 2 Receive Input 4 DT R Input/Light Pen Source 5 Po wer/Signal Ground 6 Lig ht Pen Data 7 CTS Input 8 RTS Output 9 +5VDC 9-Pin D-Type Connector USB Powe ...

  • Metrologic Instruments MS7120 - page 38

    34 S CANNER AND C ABLE T ERMINATIONS Cable Connector Configurations (Host End) Keyboard Wedge Po werLink Cable 59-59002 x -3 Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5 +5 Volts DC 5-Pin DIN, Female Pin Function 1 PC Data 2 No Connect 3 Power Ground 4 +5 Volts DC 5 PC Clock 6 No Connect 6-Pin DIN, Male Metrologic wil ...

  • Metrologic Instruments MS7120 - page 39

    35 R EGULATORY C OMPLIAN CE Safety ITE Equipment IEC 60950-1, EN 60950-1 Laser Laser Class 1: IEC 60825-1:1993+A1+A2, EN 60825-1:1994+A1+A2 Caution Use of controls or adjustments or performanc e of procedures othe r than those specified herein may result in hazardous laser light ex posure. Under no circumstances should the customer attempt to servi ...

  • Metrologic Instruments MS7120 - page 40

    36 R EGULATORY C OMPLIAN CE EMC Emissions: FCC Part 15, ICES-003, CISPR 22, EN 55022 Immunity: CISPR 24, EN 55024 Changes or modifications not expressly approv ed by the part y responsible for compliance could void the user’s authority to operate the equipment. Class A Devices The following is applicable w hen the scanner cable is greater in leng ...

  • Metrologic Instruments MS7120 - page 41

    37 R EGULATORY C OMPLIAN CE EMC Changes or modifications not expressly approv ed by the part y responsible for compliance could void the user’s authority to operate the equipment. Class B Devices The following is applicable w hen the scanner cable is les s than 3 meters (9.8 feet) i n length w hen fully extende d: Les instructions ci-de ssous s? ...

  • Metrologic Instruments MS7120 - page 42

    38 L IMITED W ARRANTY The MS7120 Orbit ® scanne rs are manufactured by Metrol ogic at its Suzhou, China fa cility. The MS7120 Orbit scanners have a thre e (3) year limited w arranty fr om the date o f manufacture. Metrologi c warrants and represents that all MS7120 Orbit scanner s are free of all defects i n material, workmanship and design, and h ...

  • Metrologic Instruments MS7120 - page 43

    39 P ATENTS Patent Information This METROLOGIC product may be covered by, but is not limited to, one or more of the following U.S. Patents: U.S. Patent No.; 4,960,985; 5,081,342; 5,216,232; 5,260,553; 5,340,971; 5,340,973; 5,424,525; 5,468,951; 5,484,992; 5,525,789; 5,528,024; 5,557,0 93; 5,591,953; 5,616,908; 5,627,359; 5,637,852; 5,661,292; 5,777 ...

  • Metrologic Instruments MS7120 - page 44

    40 I NDEX A AC .................................. see power accessories ............................... 2, 3 adapter .................................... 9, 34 B bar co de ...................................... 30 bar widt h ...................................... 22 beep ............................ see indicator blue ............................. ...

  • Metrologic Instruments MS7120 - page 45

    41 I NDEX P patents ......................................... 39 pin assignment s cable .................................. 33– 34 scanner .................................... 32 port .............................. 7–11, 18–21 power .................. 2, 3, 7–11, 22, 23 PowerLink........................ see cable protoc ol................... ...

  • Metrologic Instruments MS7120 - page 46

    42 ...

  • Metrologic Instruments MS7120 - page 47

    ...

  • Metrologic Instruments MS7120 - page 48

    May 2008 Printed in the USA 00 - 02282 D ...

Fabbricante Metrologic Instruments Categoria All in One Printer

I documenti che otteniamo dal fabbricante del dispositivoMetrologic Instruments MS7120 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Metrologic Instruments
- manuali per l’uso MS7120
- schede prodotto Metrologic Instruments
- opuscoli
- o etichette energetiche Metrologic Instruments MS7120
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Metrologic Instruments MS7120.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Metrologic Instruments MS7120, manuali di manutenzione, brevi manuali o manuali utente Metrologic Instruments MS7120. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Metrologic Instruments MS7120.

Manuale completo del dispositivo Metrologic Instruments MS7120, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Metrologic Instruments MS7120 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Metrologic Instruments MS7120.

Il manuale per l’uso completo Metrologic Instruments, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Metrologic Instruments MS7120 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Metrologic Instruments MS7120, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Metrologic Instruments MS7120 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Metrologic Instruments MS7120 - che ci dovrebbe aiutare nei primi passi durante l'uso Metrologic Instruments MS7120
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Metrologic Instruments MS7120
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Metrologic Instruments MS7120 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Metrologic Instruments MS7120?

Utilizza il modulo sottostante

Se non hai risolto il problema con Metrologic Instruments MS7120 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Metrologic Instruments MS7120 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)