    Content s 1. Safety Precautions ................ .................. .................1 2. Product features .................... ...................................2 1. Specifications ................... ..............................2 2. Power supply capacity ...... .............................. 2 3. External Dimensions ..... ................... . ...

  • Mitsubishi Electronics PAC-SC51KUA - page 2

    - 1 - This manual details how to install the P AC- SC51KUA power supply unit an d its wiring with the centra lized controller and the ind oor units. For the information about how to install the centralized controller or the indoor unit s, see the appropriate installation manua l. For your safety , first read 1 Safety Precautions described below bef ...

  • Mitsubishi Electronics PAC-SC51KUA - page 3

    - 2 - 2 Product features This unit supplies DC power to the centrali zed controller AG-150A via the centralized controller system M-NET transmission line and DC power line. Cannot be used with G-50A. 1. Specifications 2. Power supply capacity 2-1. 24V power supply (TB3) Supplies power to one AG-150A unit. Not connectable to mu ltiple AG-150A units. ...

  • Mitsubishi Electronics PAC-SC51KUA - page 4

    - 3 - 3. External Dimensions TB2,TB3 TB1 271 ( 10- 11 / 16 ) 90 ( 3- 9 / 16 ) 155 ( 6- 1 / 8 ) 130 ( 5- 1 / 8 ) 169 ( 6- 11 / 16 ) 72 ( 2- 7 / 8 ) T Unit: mm (in.) 00gb_WT05372X04_7.b ook Page 3 Monday, Sept ember 28, 2009 2:03 PM ...

  • Mitsubishi Electronics PAC-SC51KUA - page 5

    - 4 - 3I n s t a l l a t i o n 1. Parts List The part s listed below ar e included with the unit. 1 P AC-SC51KUA 1 unit 2 L-shaped mounting brackets 1 set 3 M4 screw (4 pieces for attaching th e P AC-SC51KUA and the mounting bracket) 4 Installation Manual 2. Field-supplied Parts Obtain the part s listed below before installing the unit. *1 When ins ...

  • Mitsubishi Electronics PAC-SC51KUA - page 6

    - 5 - 4. Unit installation Attach the unit to the meta l control p anel box using M4 screws as shown in Fig. 3-2. 4W i r i n g 1. Cover Removal and Installation Remove the three mountin g screws and the cover . Attach the corner to the unit by tighteni ng the three screws indicated in Figure 4-1. CAUTION The unit should be attached on all four corn ...

  • Mitsubishi Electronics PAC-SC51KUA - page 7

    - 6 - 2. Power line Wire the power and ground cables to L/L1, N/L2 and the groun d cable terminals on TB1 as shown in Fig. 4-2. 3. DC Power Supply and M-NET T ransmission Line 3-1. When connecting to the centralized controller (AG-150A) (1) Without the use of an exp ansion controller (P AC-YG50ECA) (a) Connected via the terminal block The DC power ...

  • Mitsubishi Electronics PAC-SC51KUA - page 8

    - 7 - (b) Connecting the connector When installing the unit in the mounti ng att achment A type (P AC-YG85KTB) (sol d separately), DC power cable and M-NET transmission line can be connected with the connector as shown in the Fig. 4-4. Conn ectable to the connector using the cable that is supplied with AG-150A (Refer to the Instal lation Manual tha ...

  • Mitsubishi Electronics PAC-SC51KUA - page 9

    - 8 - (2) With the use of an expansion controller (P AC-YG50ECA) Only connect the DC power cabl e. (Use only TB3 or CN2.) (a) Connected via the terminal block (TB3) FG V+ V- A B S CN1 CN2 24VDC M-NET ABS V + V - F G M-NET Output CN1 CN2 TB2 TB3 24VDC Power supply unit (P AC-SC51KUA) Centralized controller (AG-150A) Cable Clamp DC power supply line ...

  • Mitsubishi Electronics PAC-SC51KUA - page 10

    - 9 - (b) Connecting the connector (CN2) After connection for the each cable, fast en each cable with the cable fixture. 3-2. When not connecting to the cen tralized controller (AG-150A) Only use the M-NET output (TB2 or CN1). CAUTION • The 24 VDC power supply is for exclusive us e with the centralized controller (AG-150A). Power supply unit (P A ...

  • Mitsubishi Electronics PAC-SC51KUA - page 11

    - 10 - 5 M-NET T ransmission Lines Length • Maximum length of M-NET tr ansmission : 500m (1640 ft) *1 • Maximum power feeding length : 200m (656 ft ) Example 1) Maximum length of M-NET transmission line: 1 L1+L2+L3+ 5+ 1+ 2 ( 3) 500m (1640 ft) 2 L1+L2+L3+ 5+ 4 500m (1640 ft) 3 L1+L2+L4+ 6+ 7 ( 8) 500m (1640 ft) 4 2 ( 3) + 1+ 5+L3+L4+ 6+ 7 ( 8) ...

  • Mitsubishi Electronics PAC-SC51KUA - page 12

    HEAD OFFICE: TOKYO BLDG . , 2-7-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAP AN Authorized representative in EU: MITSUBISHI ELECTR IC EUROPE B.V . HARMAN HOUSE, 1 GEORGE STREET , UXBRIDGE, MIDDLESEX UB8 1QQ, U.K. WT05372X04 Printed in Japan Recycled Paper Please be sure to put the cont act address/telephone number on this manual before handing it ...

Fabbricante Mitsubishi Electronics Categoria Welding System

I documenti che otteniamo dal fabbricante del dispositivoMitsubishi Electronics PAC-SC51KUA possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Mitsubishi Electronics
- manuali per l’uso PAC-SC51KUA
- schede prodotto Mitsubishi Electronics
- opuscoli
- o etichette energetiche Mitsubishi Electronics PAC-SC51KUA
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Mitsubishi Electronics PAC-SC51KUA.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Mitsubishi Electronics PAC-SC51KUA, manuali di manutenzione, brevi manuali o manuali utente Mitsubishi Electronics PAC-SC51KUA. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Mitsubishi Electronics PAC-SC51KUA.

Manuale completo del dispositivo Mitsubishi Electronics PAC-SC51KUA, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Mitsubishi Electronics PAC-SC51KUA dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Mitsubishi Electronics PAC-SC51KUA.

Il manuale per l’uso completo Mitsubishi Electronics, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Mitsubishi Electronics PAC-SC51KUA - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Mitsubishi Electronics PAC-SC51KUA, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Mitsubishi Electronics PAC-SC51KUA che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Mitsubishi Electronics PAC-SC51KUA - che ci dovrebbe aiutare nei primi passi durante l'uso Mitsubishi Electronics PAC-SC51KUA
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Mitsubishi Electronics PAC-SC51KUA
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Mitsubishi Electronics PAC-SC51KUA in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Mitsubishi Electronics PAC-SC51KUA?

Utilizza il modulo sottostante

Se non hai risolto il problema con Mitsubishi Electronics PAC-SC51KUA con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Mitsubishi Electronics PAC-SC51KUA è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)