Manuale per l’uso Hill Phoenix OSAA

32 pagine 1.19 mb
Scarica

Vai alla pagina of 32

Summary
  • Hill Phoenix OSAA - page 1

    DELI CASES MODEL: OSAA HAND B O O K INST ALLA TION & OPERA TION 9/03 P061773M ...

  • Hill Phoenix OSAA - page 2

    ...

  • Hill Phoenix OSAA - page 3

    Welcome to the ORIGIN 2 display case family . We’r e very pleased you joined us. This installation and operation handbook has been especially prepar ed for everyone involved with ORIGIN 2 display cases – owners, managers, installers and maintenance personnel. Y ou’ll find this book different than traditional manuals. The most dramatic differ ...

  • Hill Phoenix OSAA - page 4

    ...

  • Hill Phoenix OSAA - page 5

    1 T ABLE OF CONTENTS GENERAL INFORMA TION – P AGES 2 - 4 General information, first step recommendations and case dimensional drawings. THE USE OF CASTERS – P AGE 5 Cases roll on casters–general use and castor r emoval. LINE-UP – P AGES 6 - 7 A ten step procedur e for initial case lineup with illustrations. TRIM-OUT – P AGES 8 - 9 A sixte ...

  • Hill Phoenix OSAA - page 6

    GENERAL INFORMA TION DESCRIPTION OF CASES : The refrigerated display cases described in this handbook are part of the Hill PHOENIX , Origin 2 design series. Specifically covered in this manual is model OSAA, self-contained service deli case. STORE CONDITIONS : Hill PHOENIX cases are designed to operate in an air conditioned store with a system that ...

  • Hill Phoenix OSAA - page 7

    3 54 15/16 in [139.5 cm] 33 1/4 in [84.5 cm] 11 1/2 in [29.2 cm] 1 3/16 in [3.0 cm] 5 13/16 in [14.7 cm] FLA T REAR SILL (OPTIONAL) REAR SLIDING DOORS 21 1/2 in [54.6 cm] 28 3/8 in [72.0 cm]* 35 11/16 in [90.7 cm] 38 5/16 in [97.3 cm] 49 1/16 in [124.6 cm] 22 1/2 in [57.2 cm] 27 1/4 in [69.2 cm] 32 3/16 in [81.8 cm] 30 1/2 in [77.5 cm] 10 5/16 in [ ...

  • Hill Phoenix OSAA - page 8

    31 11/16" 71 1/4" 4" 6' CASE FRONT OF CASE 4 GENERAL INFORMA TION BASEHORSE LOCA TIONS FOR MODEL OSAA ...

  • Hill Phoenix OSAA - page 9

    5 34 12 CASES MOVE ON CASTERS FOR EASIER INST ALLA TION CASTERS MA Y BE DISCARDED. ROLL OUT OF TRUCK . When there is a truck - level delivery dock, cases may be rolled dir ectly from the truck to the store floor . [CAUTION] If skid boar ds are requir ed to unload cases, casters should be removed prior to sliding them down the skid; after which they ...

  • Hill Phoenix OSAA - page 10

    6 LINE UP 1 5 Consult With General Contractor Ask the general contractor if there have been changes in the building dimensions since the print you are using was issued. Also, ask the points of refer ence from which you should take dimensions to locate the cases. Set Shims On Basehorse Locations Locate basehorse positions along chalk lines. Spot shi ...

  • Hill Phoenix OSAA - page 11

    10 Bolt Cases T ogether Using Bolt Holes Provided Push cases tightly together . Bolt cases together through the five holes provided in the “C” frame and pipe chase as shown in illustration. Tighten until all margins are equal; do not over tighten. 9 Loosen Bumper And Cornice Loosen screws on master bumper . Move bumper joint to a position for s ...

  • Hill Phoenix OSAA - page 12

    8 Install plenum covers under deck pans. The plenum covers are shipped loose in the case and are installed between the lower rear baf fle and the fan plenum. 6 Seal joints along pipe chase seam with the caulk provided. Now that cases have been positioned and leveled, you may proceed to trim-out case lineup. T rim parts have been designed to be appl ...

  • Hill Phoenix OSAA - page 13

    9 9 Close joints of front panel. The panel is slotted on the bottom to allow left or right adjustment as requir ed. 10 Install curved front panel joint (if cases come equipped with curved front pan- els). Curved panel joints are shipped loose in the case and are attached with the screws pr ovided. Wide joints (1”) are for case-to-case joining and ...

  • Hill Phoenix OSAA - page 14

    REFRIGERA TION COMPONENTS Refrigeration components for the OSAA-6’ are easily accessible in the tank and underneath the case. The expansion valve and suction line 1/4” access valve are both located in the left hand front side of the tank and are accessible without lifting the fan plenum. These components may be reached by lifting only the left ...

  • Hill Phoenix OSAA - page 15

    11 Access V alve - Access port on the evaporator that allows service personnel to check system pr essure. Accumulator - A device installed on the suction line that is used to boil off small amounts of liquid r efrig- erant so liquid does not reach the compr essor . Compressor - An electrically driven piston pump that pumps vapor refrigerant from a ...

  • Hill Phoenix OSAA - page 16

    12 PLUMBING The drain outlet is located front and center of the cases for convenient access and is specially molded out of ABS material. The “P” trap, furnished with the case, is constructed of schedule 40 PVC pipe. Care should be given to assure that all connec- tions are water tight and sealed with the appropriate PVC or ABS cement. The drain ...

  • Hill Phoenix OSAA - page 17

    13 ELECTRICAL HOOKUP DEFROST HEA TERS, 208/240 VOL TS L1 L2 RED BLUE EV APORA TOR F ANS, 120 VOL T WIRE NUMBER COMPONENT COLOR CODING BLACK TEMPERA TURE CONTROL, 120 VOL T LIGHTS, 120 VOL T DEFROST TERMINA TION CONTROL, 120 VOL T WHITE 3 4 11 12 19 20 21 YELLOW YELLOW PURPLE ORANGE 23 WIRING NUMBERS AND COLORS EQUIPMENT GROUNDING CONDUCTOR GREEN - ...

  • Hill Phoenix OSAA - page 18

    14 CONTROL SETTINGS- MODEL OSAA-6’ Manual Defr ost Button Enter Button Up Button Down Button Fan Status LED Compressor Status LED Defrost Status LED Factory Settings Parameter Description OSAA-6’ Setpoint HY Hysteresis (dif ferential) [1 to 9 o F/ o C] LL Setpoint Low Limit [67 o F (55 o C) to HL] HL Setpoint High Limit [LL to 99 o F/ o C] CC A ...

  • Hill Phoenix OSAA - page 19

    15 Error Code System Status F2 Indicates an open or shorted evaporator sensor . Corr ect problem to r eset control. } } } F1 Indicates an open or shorted temperature sensor . Cycle Power to reset contr ol. A2 Digital input is closed and digital input option (if) 1 is selected. A3 Digital input is open for longer than time delay (id) and digital inp ...

  • Hill Phoenix OSAA - page 20

    HTR1 FAN MOTOR J3 P3 FAN MOTOR M1 M2 HTR2 SHELF LIGHTS (OPTIONAL) DEF. TERM. CONTROL (OPTIONAL) TEMP. CONTROL (OPTIONAL) FRONT GLASS ANTI-COND HEATER DEFROST HEATERS (OPTIONAL) 13 12 11 21 23 20 14 19 4 L1 L2 3 RED BLK EB6 WHT BLK EB6 WHT RED BLU BLU BLU BLU EB2 EB1 YEL BLK YEL WHT WHT BLK RED RED BLU RED BLU BLU BLU J2-2 J2-1 BLUE BLUE NOSE LIGHTS ...

  • Hill Phoenix OSAA - page 21

    17 CASE OPERA TION American Style Self-Contained Curved Glass Service Deli Mer chandiser OSAA - 6’ All measurements are taken per CRMA specifications. Medium T emperature Defrost Schedule No. Per Day Hours 1 12 midnight 2 12 am - 12 pm 3 6 am - 2 pm - 10 pm 4 12 - 6 am - 12 - 6 pm 4 NOTE: - - - not an option on this case model. Defrost Contr ols ...

  • Hill Phoenix OSAA - page 22

    18 DEFROST AND TEMP CONTROL • Electric defrost termination contr ol sensor bulb location • Electric defrost termination pr obe location • T emperature contr ol sensor bulb location (OSA) It is important to consult the control setting guidelines shown on page 17 before setting defrost times. Further adjustment may be requir ed depending on sto ...

  • Hill Phoenix OSAA - page 23

    4 2 3 1 19 AIR FLOW AND PRODUCT LOADING Cases have been designed to provide maxi- mum product capacity within the r efrigerated air envelope. It is important that you do not overload the food product display so that it impinges on the air flow pattern. DISCHARGE..............1 LOAD LIMIT ...............2 AIR FLOW ..................3 RETURN AIR GRIL ...

  • Hill Phoenix OSAA - page 24

    20 USE AND MAINTENANCE CASE CLEANING Case is designed to facilitate cleaning. There is a wide radius formed on the front and back of the inside bottom that helps accelerate liquid flow and eliminates difficult-to- clean sharp corners. All surfaces pitch to a deep-drawn drain trough that angles towar d the front and center of case where the waste ou ...

  • Hill Phoenix OSAA - page 25

    21 F ANS The evaporator fans are equipped with 5 watt fan motors, 1550 RPM’ s. The motor has a counter clockwise rotation when viewed fr om the shaft end. The fan blades are 6” in diameter and the blades ar e pitched according to the charts below . It is impor - tant that the blade pitch be maintained as spec - ified. Do not attempt a field mod ...

  • Hill Phoenix OSAA - page 26

    E10 E11 E09 23 11 24 9 1 26 2 17 88 87 22 5 28 20 3 48 53 55 56 46 9a 69 21 29 36 42 49 E01 77 81 82 66 P AR TS ORDERING MODEL OSAA 22 50 E06 E07 E09 E11 E10 E20 ...

  • Hill Phoenix OSAA - page 27

    23 Location Part Descriptions Number 1 Kickplate , Storm Grey 2 Master Bumper , Featherstone, Smoke, White, French V anilla, Black 3 Lower Front Panel , Painted or Stainless 5 Front Glass, Lift-Up Thermopane 9 Deck Pan , Painted, Unpainted, Stainless 9a Plenum Cover 11 Front Baf fle , Aluminum, Painted White, Custom Color , or Stainless 17 Nose Bum ...

  • Hill Phoenix OSAA - page 28

    24 P AR TS ORDERING Procedure 1. Contact the Service Parts Department Hill PHOENIX 1925 Ruf fin Mill Road Colonial Heights, Virginia 23834 T el: 800-283-1109 Fax: 804-526-3897 2. Pr ovide the following information about the part you are or dering: • Model number and serial number of the case on which the part is used. • Length of part, if appli ...

  • Hill Phoenix OSAA - page 29

    25 NOTES ...

  • Hill Phoenix OSAA - page 30

    26 NOTES ...

  • Hill Phoenix OSAA - page 31

    6/00 W ARRANTY HEREINAFTER REFERRED TO AS MANUF ACTURER FOURTEEN MONTH W ARRANTY . MANUF ACTURER’S PRODUCT IS WARRANTED TO BE FREE FROM DEFECTS IN MA TERIAL AND WORKMANSHIP UNDER NORMAL USE AND MAINTENANCE FOR A PERIOD OF FOURTEEN MONTHS FROM THE DA TE OF ORIGINAL SHIPMENT . A NEW OR REBUIL T P ART TO REPLACE ANY DEFECTIVE P A R T WI LL BE PROVID ...

  • Hill Phoenix OSAA - page 32

    1925 Ruffin Mill Road, Colonial Heights, V A 23834 Due to our commitment to continuous improvement all specifications are subject to change without notice. Hill PHOENIX is a Sustaining Member of the American Society of Quality . CRMA endorsed Visit our web site at www .hillphoenix.com 804-526-4455 ASH3090 W arning Maintenance & Case Car e When ...

Fabbricante Hill Phoenix Categoria Carrying Case

I documenti che otteniamo dal fabbricante del dispositivoHill Phoenix OSAA possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Hill Phoenix
- manuali per l’uso OSAA
- schede prodotto Hill Phoenix
- opuscoli
- o etichette energetiche Hill Phoenix OSAA
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Hill Phoenix OSAA.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Hill Phoenix OSAA, manuali di manutenzione, brevi manuali o manuali utente Hill Phoenix OSAA. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Hill Phoenix OSAA.

Manuali per l’uso simili

Manuale completo del dispositivo Hill Phoenix OSAA, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Hill Phoenix OSAA dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Hill Phoenix OSAA.

Il manuale per l’uso completo Hill Phoenix, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Hill Phoenix OSAA - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Hill Phoenix OSAA, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Hill Phoenix OSAA che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Hill Phoenix OSAA - che ci dovrebbe aiutare nei primi passi durante l'uso Hill Phoenix OSAA
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Hill Phoenix OSAA
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Hill Phoenix OSAA in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Hill Phoenix OSAA?

Utilizza il modulo sottostante

Se non hai risolto il problema con Hill Phoenix OSAA con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Hill Phoenix OSAA è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)