Manuale per l’uso GE 49-7419-2

28 pagine 0.6 mb
Scarica

Vai alla pagina of 28

Summary
  • GE 49-7419-2 - page 1

    49-7419-2 04-02 JR Air Con di t i o n ers Safety Instr uctions . . . . . . . . . . .2 Operating Instr uctions Controls—Dip Switches . . . . . .3–5 Controls—T erminal Connections . . . . . . . . . . . . . .6, 7 On/Off Switch . . . . . . . . . . . . . . .8 V entilation Control . . . . . . . . . . .8 Care and Cleaning Air Filters . . . . . . . . ...

  • GE 49-7419-2 - page 2

    Customer Service T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions IMPORT ANT SAFETY INFORMA TION. READ ALL INSTRUCTIONS BEFORE USING. W ARNING! For your safety , the information in this manual must be followed to minimize the risk of fire, electric shock, or to prevent property damage, personal injury , or loss of ...

  • GE 49-7419-2 - page 3

    Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Customer Service 3 Controls–dip switches. GEAppliances.com The dip switch controls are located behind the front case panel, through an opening on the front of the unit. T o access the dip switches, remove the front case panel by removing the filter , taking out th ...

  • GE 49-7419-2 - page 4

    Consumer Support T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions 4 Controls–dip switches. Freeze Sentinel (Requires room air sensor kit–RA VRMS) When this switch is enabled (UP) , it turns OFF the freeze sentinel protection feature. With the switch disabled (DOWN) , the freeze sentinel is activated which auto ...

  • GE 49-7419-2 - page 5

    5 Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Consumer Support GEAppliances.com T emperature Limiting (Requires room air sensor kit–RA VRMS) T emperature limiting can reduce energy costs by limiting the lowest temperature that can be set for cooling and the highest temperature that can be set for heating. T ...

  • GE 49-7419-2 - page 6

    6 Consumer Support T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions Controls—terminal connections. Controls–T erminal Connections The terminal connections are located behind the front case panel through an opening on the front of the unit. T o access the terminal connections, remove the front panel by removing ...

  • GE 49-7419-2 - page 7

    Remote Thermostat The unit will be controlled by a remote thermostat. IMPORT ANT : The Zoneline thermostat connections provide 24V AC only . If using a digital/electronic wall thermostat, you must set it to the 24V AC setting. See the Installation Instructions for the wall thermostat. CAUTION: Damage to a wall thermostat or to the Zoneline electron ...

  • GE 49-7419-2 - page 8

    8 Consumer Support T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions Other features of your Zoneline. About Heat Pumps (on some models) Heat pumps can reduce operating costs by exchanging heat from the outside air—even when the outside temperature is below freezing— and releasing that heat indoors. T o get the ...

  • GE 49-7419-2 - page 9

    Indoor/Outdoor Coils The exhaust coils on the Zoneline should be checked regularly . If they are clogged with dirt or soot, they may be professionally steam cleaned by your GE ser vice center . Y ou will need to remove the unit from the case to inspect the coils because the dirt build-up occurs on the exhaust side. 9 Safety Instructions Operating I ...

  • GE 49-7419-2 - page 10

    BEFORE YOU BEGIN Installation Zoneline Air Instructions Conditioners Read these instr uctions completely and carefully . • IMPORT ANT – Save these instructions for local inspector’ s use. • IMPORT ANT – Obser ve all governing codes and ordinances. • Note to Installer – Be sure to leave these instructions with the owner . • Note to O ...

  • GE 49-7419-2 - page 11

    11 Installation Instructions ELECTRICAL REQUIREMENTS 230/208 VOL T ELECTRICAL SUPPL Y T andem 15 Amp 230/208 volt receptacle configuration Perpendicular 20 Amp Large T andem 30 Amp • Use ONLY the wiring size recommended for single outlet branch circuit. • Proper current protection is the responsibility of the owner . A power supply kit must be ...

  • GE 49-7419-2 - page 12

    REMOVE JUNCTION BOX COVER • Remove the junction box cover by taking out the front two screws. 1 Junction box Installation Instructions 12 DIRECT CONNECT APPLICA TIONS FOR 265 VOL T DIRECT CONNECT APPLICA TIONS ONL Y IMPORT ANT: Connection of a 265V AC product to a branch circuit MUST be done by direct connection in accordance with the National El ...

  • GE 49-7419-2 - page 13

    13 Installation Instructions DIRECT CONNECT APPLICA TIONS MAKE WIRE LEAD CONNECTIONS INSIDE THE JUNCTION BOX 1. Make all wire connections by using appropriate UL-listed electrical connectors and techniques. 2. Select the applicable wiring situation and follow the instructions accordingly: 3. Be sure that all wire leads are inside the junction box a ...

  • GE 49-7419-2 - page 14

    Installation Instructions 14 ZONELINE COMPONENTS Case Zoneline unit Front Case Panel REQUIRED ACCESSORIES (Check the “Essential Elements” label on the unit.) Architectural Louver RA V AL1 W all Plenum RA VWP6 - 6 ″ D x 19 3 ⁄ 4 ″ W x 32 ″ H RA VWP8 - 8 ″ D x 19 3 ⁄ 4 ″ W x 32 ″ H RA VWP12 - 12 ″ D x 19 3 ⁄ 4 ″ W x 32 ″ H ...

  • GE 49-7419-2 - page 15

    Installation Instructions 15 TYPICAL UTILITY CLOSET AND DIMENSIONS (FOR REFERENCE ONL Y) Side View T op View Architectural Louver 10 ″ duct Door/access panel 3 ″ min. 5 ″ min. Unit front 3 ″ min. Exterior/Outside Unit Outside wall Wall plenum Inside wall Air discharge outlet Rigid ductwork Flexible or rigid duct Wall plenum divider 31 ″ O ...

  • GE 49-7419-2 - page 16

    Installation Instructions 16 UTILITY CLOSET CONNECTION LOCA TIONS IMPOR T ANT : Plan and locate plenum, wall plug, drain and thermostat carefully to avoid interference. Hard-to-reach locations will make installation and service difficult! Refer ence Dimensions A Thermostat cable: 9 1 ⁄ 2 ′ long B Power cord: 60 ″ long C Case width and depth: ...

  • GE 49-7419-2 - page 17

    Installation Instructions 17 RETURN AIR GRILLE INST ALLA TION OPTIONS The room return air grille may be installed toward the front or either side of the unit. Improper return air arrangements will cause per formance problems. There are three indoor Return Air Grille Installation options. Choose the option that best suits your installation requireme ...

  • GE 49-7419-2 - page 18

    BUILD AND INST ALL THE ZONELINE BASE PLA TFORM 1. Construct a 23 1 ⁄ 4 ″ min. x 23 1 ⁄ 4 ″ min. square platform. NOTE: The platform must have a load-bearing capacity of 175 lbs. minimum. 1 Installation Instructions 18 W ALL PLENUM AND ARCHITECTURAL LOUVER INST ALLA TION • Install the appr opriate wall plenum through the exterior wall in a ...

  • GE 49-7419-2 - page 19

    INST ALL THE DRAIN An exter nal or an inter nal drain must be attached to the drain connector . Exter nal Drain Attach a 90° PVC elbow to the unit’ s female 3/4 ″ NPT drain connector . Use the other end of the elbow to run a 3/4 ″ Sch.40 PVC pipe through the knockout holes of both the wall plenum and the architectural louver to the outside. ...

  • GE 49-7419-2 - page 20

    INST ALL AND CONNECT THE CASE 1. Remove the front case panel and pull the unit out of the case. Place the empty case onto the platform in the closet with the outdoor side facing the wall plenum opening. Align the case to the plenum opening and attach with six screws. 2. Adjust all four leveling legs until the case is level. 3. Using field-supplied ...

  • GE 49-7419-2 - page 21

    T op duct Clamp Case top duct adjusting screws MAKE UNIT ELECTRICAL CONNECTIONS 1. Connect the thermostat wires to the unit and set the dip switches to the appropriate settings. NOTE: See the Controls–T erminal Connections and Controls–Dip Switches sections of this manual and the manual with the separate thermostat for proper connections and se ...

  • GE 49-7419-2 - page 22

    Installation Instructions SERVICING W ARNING: Before ser vicing, switch power off at the ser vice panel and lock the area to prevent power from being switched on accidentally . When the area cannot be locked, securely fasten a prominent warning device, such as a tag, to the ser vice panel. NOTE: W e strongly recommend that any ser vicing be per for ...

  • GE 49-7419-2 - page 23

    Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Consumer Support Before Y ou Call For Service… GEAppliances.com T roubleshooting T ips Problem Possible Causes What T o Do Zoneline does The unit is • Make sure the Zoneline plug is pushed completely not start unplugged. into the outlet. The fuse is blown/circui ...

  • GE 49-7419-2 - page 24

    Consumer Support T roubleshooting T ips Care and Cleaning Operating Instructions Safety Instructions 24 Normal Operating Sounds Y ou may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency . Y ou may hear re ...

  • GE 49-7419-2 - page 25

    25 General Electric Company W ar ranty Registration Depar tment P .O. Box 32150 Louisville, KY 40232-2150 Please place in envelope and mail to: ✁ Cut here ...

  • GE 49-7419-2 - page 26

    26 Consumer Pr oduct Ownership Registration Important Mail T oday! General Electric Company Louisville, Kentucky GEAppliances.com First Name Mr . ■ ■ Ms. ■ ■ Mrs. ■ ■ Miss ■ ■ Street Address City State Date Placed In Use Month Day Y ear Zip Code Apt. # Last Name Phone Number _ _ Consumer Pr oduct Ownership Registration Dear Customer ...

  • GE 49-7419-2 - page 27

    Safety Instructions Operating Instructions Care and Cleaning T roubleshooting T ips Consumer Support 27 V ertical Zoneline Warranty . For The Period Of: GE Will Replace: One Y ear Any part of the Zoneline which fails due to a defect in materials or workmanship. During this From the date of the full one-year warranty , GE will also provide, free of ...

  • GE 49-7419-2 - page 28

    Printed in China Consumer Support. GE Appliances W ebsite GEAppliances.com Have a question or need assistance with your appliance? T ry the GE Appliances W ebsite 24 hours a day , any day of the year! For greater convenience and faster service, you can now download Owner’s Manuals, order parts, catalogs, or even schedule service on-line. You can ...

Fabbricante GE Categoria Air Conditioner

I documenti che otteniamo dal fabbricante del dispositivoGE 49-7419-2 possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici GE
- manuali per l’uso 49-7419-2
- schede prodotto GE
- opuscoli
- o etichette energetiche GE 49-7419-2
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso GE 49-7419-2.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione GE 49-7419-2, manuali di manutenzione, brevi manuali o manuali utente GE 49-7419-2. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto GE 49-7419-2.

Manuali per l’uso simili

Manuale completo del dispositivo GE 49-7419-2, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare GE 49-7419-2 dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti GE 49-7419-2.

Il manuale per l’uso completo GE, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale GE 49-7419-2 - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice GE 49-7419-2, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per GE 49-7419-2 che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo GE 49-7419-2 - che ci dovrebbe aiutare nei primi passi durante l'uso GE 49-7419-2
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del GE 49-7419-2
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio GE 49-7419-2 in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su GE 49-7419-2?

Utilizza il modulo sottostante

Se non hai risolto il problema con GE 49-7419-2 con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con GE 49-7419-2 è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (0)