Manuale per l’uso Scytek electronic 5100RS-22W

36 pagine 0.78 mb
Scarica

Vai alla pagina of 36

Summary
  • Scytek electronic 5100RS-22W - page 1

    5100RS -2 2 W SERIES VEHICLE SECURITY SYSTEM WITH REMOTE START PRODUCT MANUAL ...

  • Scytek electronic 5100RS-22W - page 2

    L i m i t e d L i f e t i m e W a r r a n t y This vehicle security system is warranted to the original purchaser , to be free from defects in material and workmanship. The manufacturer will rep air or replace at its option, and free of charge for the first twelve (12) months, any part that proves defective in material or workmanship under normal i ...

  • Scytek electronic 5100RS-22W - page 3

    1. About Y our System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 1 2. Remote T r ansmitters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 2 Remote T r ansmitter Description . . . . . . . . . . . . . . . . . . . . ...

  • Scytek electronic 5100RS-22W - page 4

    ...

  • Scytek electronic 5100RS-22W - page 5

    The ScyT ek Galaxy 5100RS Plus is a combination vehicle securit y and remote starting system featuring a built-in "ScyNet Network P ort" that allows direct connection of optional accessory modules and a PC interface off ering expanded system operation. With proper installation this system will provide superior protection and performance f ...

  • Scytek electronic 5100RS-22W - page 6

    Standard Remote Transmitter Description The Galaxy 5100RS Plus is compatible with the optional 5-button R emote T ransmit ters used to control system operations. Note : Using the optional PC or P ocket PC interface with the network softw are, it is possible to reconfigure the functionality of the tr ansmitter buttons. The standard (default) setting ...

  • Scytek electronic 5100RS-22W - page 7

    Adding/Replacing Transmitters T o replace lost or stolen tr ansmitters or to add additional tr ansmitters into the system, have all desired transmit ters ready and follow the steps below . Note : Up to 4 transmit ters can be programmed to oper ate the system. T o er ase any previously stored transmit ter codes, be sure to program all 4 tr ansmitter ...

  • Scytek electronic 5100RS-22W - page 8

    Page 4 - Galaxy 5100RS-2W True Color 2-way LCD Remote Transmitter Description The Galaxy 5100RS-TC is compatible with the True Color 2-way LCD remote transmitter, offering increased range and confirmation of any activated features. Button 1 Arms the system. Button 1 also locks the doors when the system is in Valet Mode. Button 2 Disarms the system. ...

  • Scytek electronic 5100RS-22W - page 9

    Galaxy 5100RS-2W - Page 5 4. Turn off the ignition key. 5. Repeat steps 1-4 to add an additional 2-way transmitter. LCD Transmitter Battery Replacement Your Galaxy Remote Transmitter uses a 1.5 volt AAA alkaline battery, which will require replacement in time. Depending on the amount of use, the battery may last up to six months before it needs rep ...

  • Scytek electronic 5100RS-22W - page 10

    Page 6 - Galaxy 5100RS-2W LCD Backlight T ransmit ter Button 4 is used for confirmation, tr ansmitter progr amming, as well as activation of the LCD backlighting for use in the dark. Press but ton 4 momentarily to activate the L CD backlight. System Confirmation The 2-wa y transmitter's confirmation f eature allows the current vehicle status t ...

  • Scytek electronic 5100RS-22W - page 11

    Galaxy 5100RS-2W - Page 7 ...

  • Scytek electronic 5100RS-22W - page 12

    Page 8 - Galaxy 5100RS-2W Remote Arming The system monitors 6 independent areas ( zones ) while armed: doors, hood, trunk, shock sensor , optional sensor input, and the network port for future expansion. T o Arm the S ystem: 1. T urn off the ignition. 2. Press Button 1. · The siren will chirp once.* · The doors will lock. · The parking lights wi ...

  • Scytek electronic 5100RS-22W - page 13

    Galaxy 5100RS-2W - Page 9 Tamper Alert If the system was triggered while awa y , the LED will flash to indicate which zone triggered the system after disarming and turning on the ignition. The LED indication will repeat 8 times. LED Flashes (60 seconds): 1 flash = optional sensor 2 flashes = shock sensor 3 flashes = network based sensor 4 flashes = ...

  • Scytek electronic 5100RS-22W - page 14

    Page 10 - Galaxy 5100RS-2W Panic Mode In the event of an emergency the tr ansmitter’s remote P anic feature can be used to instantly trigger the alarm. T o activ ate the P anic Mode: 1. Press and hold Button 1 for 3 seconds. · The alarm will sound. · The parking lights will flash. · The doors will unlock* allowing access to the vehicle. 2. Pre ...

  • Scytek electronic 5100RS-22W - page 15

    Galaxy 5100RS-2W - Page 11 T o set the Emergency Override Code: 1. T urn on ignition. 2. Within 5 seconds, press the valet switch 5 times. · The siren will provide one long chirp, indicating that y ou have entered Progr amming. 3. Press the valet switch 4 times. · The siren will chirp each time the valet switch is pressed. 4. Within 5 seconds, pr ...

  • Scytek electronic 5100RS-22W - page 16

    Page 12 - Galaxy 5100RS-2W Remote Starting T o R emote Start the System: 1. Be sure the system is not in V alet Mode. 2. Press and hold Button 4 for three seconds. · The parking lights will flash 4 times and turn on. · The Siren will chirp 4 times. · The engine will start and run for the dur ation of its programmed Run Time.* · The heater or ai ...

  • Scytek electronic 5100RS-22W - page 17

    Galaxy 5100RS-2W - Page 13 Automatic Start Mode The Automatic Start Mode allows the vehicle to automatically start the vehicle ev ery one or two hours and run for the preset Run Time. T o turn on Auto Cold Starting: 1. T urn Ignition switch Off and w ait for 3 seconds. 2. T urn Ignition switch On and Off three times ending with I gnition in Off pos ...

  • Scytek electronic 5100RS-22W - page 18

    Page 14 - Galaxy 5100RS-2W E x t e n d e d F e a t u r e s Ignition Door Locking F or added safety , the Ignition Door Locking f eature allows vehicles equipped with power door lock systems to automatically lock the doors when the ignition is turned on. If a door is open when the ignition is turned on, the Ignition Door Locking feature is disabled ...

  • Scytek electronic 5100RS-22W - page 19

    Galaxy 5100RS-2W - Page 15 1. Thoroughly read and become familiar with the installation instructions bef ore beginning the installation. 2. R eview system contents: Main Unit T wo 5-Button R emote T ransmit ters Siren Shock Sensor Harnesses • 6-Pin starter harness • 20-Pin main harness • 4-Pin shock sensor harness • 3-Pin door lock harness ...

  • Scytek electronic 5100RS-22W - page 20

    Page 16 - Galaxy 5100RS-2W Mounting the Control Unit The control unit must only be mounted in the interior of the vehicle. Do not mount the main unit in the engine compartment. Choose a mounting location that will not be easily accessible to a thief , and will not interfere with the oper ation of any vehicle components such as f oot pedals, steerin ...

  • Scytek electronic 5100RS-22W - page 21

    Galaxy 5100RS-2W - Page 17 S y s t e m W i r i n g 6-Pin Starter Harness Pin 1 RED WIRE A : Main Power Input A (+). Connect to the bat tery or constant power wire at the ignition switch with a minimum 25 Amp supply . R emo v e the f use until the installation is complete and all wiring is check ed. Pin 2 RED WIRE B : Main Power Input B (+). Connect ...

  • Scytek electronic 5100RS-22W - page 22

    Page 18 - Galaxy 5100RS-2W when the door is open. This type of door circuit is usually found on F ord vehicles. Pin 12 GREEN WIRE : Negativ e Door Input (-). Connect to the door switch circuit wire that shows ground when the door is open. Pin 13 WHITE/BLACK WIRE : Hood Pin Input (-). Connect the to the hood pin switch. The switch must provide a gro ...

  • Scytek electronic 5100RS-22W - page 23

    Galaxy 5100RS-2W - Page 19 Jumper Selection Carefully separ ate the top and bottom halves of the main unit case. Once the cov er is removed, the parking light polarity jumper will be visible next to the parking light relay . Set the jumper f or the correct polarity output as described below , then reassembly the main unit case. Parking Light Output ...

  • Scytek electronic 5100RS-22W - page 24

    Page 20 - Galaxy 5100RS-2W Entering System Programming This system is compatible with both the optional LCD tr ansmitter or the standard AM transmit ter , all system programming can be perf ormed using either one. T o enter S ystem Programming: 1. T urn on ignition. 2. Within 5 seconds, press the valet switch 5 times. · The siren will provide thre ...

  • Scytek electronic 5100RS-22W - page 25

    Galaxy 5100RS-2W - Page 21 5. Ignition Door Unlocking. Selects whether or not the system automatically unlocks the doors when the ignition is turned off . The Ignition Door Locking feature may be progr ammed to unlock all doors or the driver’ s door only . If driver’s door only is selected, the optional P assenger Unlock wire must be connected. ...

  • Scytek electronic 5100RS-22W - page 26

    Page 22 - Galaxy 5100RS-2W for this feature. 10. Ignore Open Door Report. Bypasses the open zone warning chirps for vehicles equipped with a residual dome light circuit that remains on for a period of time after closing the door . 11. Aux 2 Auto Activate with Arm. When selected, the Auxiliary 2 output will activate when the system is armed. This fe ...

  • Scytek electronic 5100RS-22W - page 27

    Galaxy 5100RS-2W - Page 23 22. Ignition 2 Relay Program. Selects one of three operating modes for the Ignition 2 rela y output: Ignition 2, Accessory 2, or Starter 2. 23. Horn Output. When set for Horn Output the horn wire will pulse when the alarm is triggered. When Ignition 3 Output is selected, the output will activ ate during remote start to tr ...

  • Scytek electronic 5100RS-22W - page 28

    Page 24 - Galaxy 5100RS-2W W i r i n g D i a g r a m s P ositive Dome Light Negative Dome Light P ositive Horn Honk Negative Horn Honk Negative Glow Plug Starter Defeat/Anti-Grind ...

  • Scytek electronic 5100RS-22W - page 29

    Galaxy 5100RS-2W - Page 25 Negative T rigger P ositive T rigger R everse P olarity V acuum Adding Actuators F ollow the diagrams below for connecting basic door lock systems. F or T wo Stage door lock systems (separately unlocks driv er and passenger doors) see following pages. D o o r L o c k D i a g r a m s Green Wire Blue Wire ...

  • Scytek electronic 5100RS-22W - page 30

    Page 26 - Galaxy 5100RS-2W T w o S t a g e D o o r L o c k D i a g r a m s T wo Stage Negativ e T rigger T wo Stage P ositive T rigger The Galaxy 5100RS Plus is equipped with a dedicated P assenger Unlock output allowing T wo Stage Door Lock operation. When connected as shown below , disarming the system will unlock only the driver’ s door . Pres ...

  • Scytek electronic 5100RS-22W - page 31

    Galaxy 5100RS-2W - Page 27 T w o S t a g e D o o r L o c k Diagrams c o n t ’ d T wo Stage R everse P olarity T wo Stage Adding Actuators ...

  • Scytek electronic 5100RS-22W - page 32

    Page 28 - Galaxy 5100RS-2W FCC ID: OARRXAM2000 This device complies with P art 15 of FCC Rules. Operation is subject to the f ollowing two conditions: 1) This device may not cause harmf ul interference. 2) This device must accept any interf erence received, including interference that may cause undesired operation T e c h n i c a l I n f o r m a t ...

  • Scytek electronic 5100RS-22W - page 33

    Galaxy 5100RS-2W - Page 29 S t a r t e r D i a g n o s t i c s Starter doesn’t start and Side Lights flash: 3 Times - Engine RPM not detected Hood T rigger is active 4 Times - Brak e T rigger is active 5 Times - Unit is in V alet (service) mode, and start is disabled. ...

  • Scytek electronic 5100RS-22W - page 34

    Page 30 - Galaxy 5100RS-2W ...

  • Scytek electronic 5100RS-22W - page 35

    Galaxy 5100RS-2W - Page 31 N o t e s ...

  • Scytek electronic 5100RS-22W - page 36

    ScyTek Electronics 11627 Cantara Street Unit B North Hollywood, CA 91605 © ScyT ek Electronics 2004 Galaxy 5100RS-2W r4 10/21 W i r i n g D i a g r a m ScyNet Blue Star t (-) Green Emer gency brak e(-) Antenna Shock Sensor LED V alet Switch Green Lock output (-) 500mA Red +12V relay power output 100mA Blue Unlock output (-) 500mA Green/White Br ak ...

Fabbricante Scytek electronic Categoria Automobile Alarm

I documenti che otteniamo dal fabbricante del dispositivoScytek electronic 5100RS-22W possono essere suddivisi in diversi gruppi. Questi sono tra gli altri:
- disegni tecnici Scytek electronic
- manuali per l’uso 5100RS-22W
- schede prodotto Scytek electronic
- opuscoli
- o etichette energetiche Scytek electronic 5100RS-22W
Tutti sono importanti, ma le informazioni più importanti dal punto di vista di utilizzo del dispositivo possono essere trovate nel manuale per l’uso Scytek electronic 5100RS-22W.

Un gruppo di documenti denominato manuali per l’uso, è anche suddiviso in tipi più specifici, come: Manuali di installazione Scytek electronic 5100RS-22W, manuali di manutenzione, brevi manuali o manuali utente Scytek electronic 5100RS-22W. A seconda delle esigenze, si dovrebbe cercare il documento necessario. Nel nostro sito web, puoi visualizzare il manuale più popolare per l'uso del prodotto Scytek electronic 5100RS-22W.

Manuali per l’uso simili

Manuale completo del dispositivo Scytek electronic 5100RS-22W, come deve essere?
Il manuale per l’uso, denominato anche istruzioni per l’uso, o semplicemente il manuale è un documento tecnico progettato per aiutare ad utilizzare Scytek electronic 5100RS-22W dagli utenti. I manuali sono di solito scritti da uno scrittore tecnico, ma in un linguaggio accessibile a tutti gli utenti Scytek electronic 5100RS-22W.

Il manuale per l’uso completo Scytek electronic, dovrebbe includere vari elementi di base. Alcuni di loro sono meno importanti, come ad esempio: copertina / pagina del titolo o pagina di autore. Tuttavia, la parte rimanente, dovrebbe fornire informazioni importanti dal punto di vista dell'utente.

1. Introduzione e la guida su come utilizzare il manuale Scytek electronic 5100RS-22W - All'inizio di ogni manuale, dovremmo trovare indizi su come utilizzare il documento. Dovrebbe contenere informazioni sulla posizione dell’indice Scytek electronic 5100RS-22W, FAQ o i problemi più comuni : i punti che sono più spesso cercati dagli utenti di ogni manuale
2. Indice - elenco di tutti i suggerimenti per Scytek electronic 5100RS-22W che possono essere trovati nel documento corrente
3. Suggerimenti su come utilizzare le funzioni di base del dispositivo Scytek electronic 5100RS-22W - che ci dovrebbe aiutare nei primi passi durante l'uso Scytek electronic 5100RS-22W
4. Troubleshooting - sequenza sistematica delle attività che vi aiuterà a diagnosticare e, successivamente, risolvere i problemi più importanti del Scytek electronic 5100RS-22W
5. FAQ - domande più frequenti
6. Dettagli di contatto Informazioni su dove cercare il contatto con il fabbricante / servizio Scytek electronic 5100RS-22W in un dato paese, se il problema non può essere risolto da noi stessi.

Hai una domanda su Scytek electronic 5100RS-22W?

Utilizza il modulo sottostante

Se non hai risolto il problema con Scytek electronic 5100RS-22W con l'aiuto del manuale che hai trovato, fai una domanda utilizzando il modulo sottostante. Se un utente ha avuto un problema simile con Scytek electronic 5100RS-22W è probabile che voglia condividere il modo di risolverlo.

Riscrivi il testo dall’immagine

Commenti (1)

Александр

Бывает без причины сам отключается со звуком и сам включается снова.